Rope Pull Emergency Stop Switch

For the Latest Information

On the Internet: 

www.omron-industrial.com

 or 

www.sti.com

S

a

fety prec

a

ution

s

Oper

a

ting in

s

truction

s

Installation must be in accordance with the following steps and stated
specifications and should be carried out by suitably competent personnel.
Adherence to the recommended maintenance instructions forms part of
the warranty.

!

WARNING

Do not defeat, tamper, remove or bypass this unit.
Severe injury to personnel could result.

W

!

WARNING

1.Installation of all Safety Rope Switch systems must be in accordance

with a risk assessment for the individual application. Installation must
only be carried out by competent personnel and in accordance with
these instructions.

2.Rope support eyebolts must be fitted at 2.5 m. min. to 3 m. max. inter-

vals along all rope lengths between switches. The rope must be
supported no more than 500 mm from the switch eyebolt or Safety
Spring (if used). It is important that this first 500 mm is not used as part
of the active protection coverage.

3.M5 mounting bolts must be used to fix the switches. Tightening torque

for mounting bolts to ensure reliable fixing is 4 Nm. Tightening torque for
the lid screws, conduit entry plugs and cable glands must be 1.5 Nm to
ensure IP seal. Only use correct sizing glands for conduit entry and
cable outside diameter.

4.Tensioning of rope is achieved by use of tensioner / gripper assemblies.

Upon installation, tension to mid-position as indicated by the red arrows
in the viewing window of each switch. Check operation for all switches
and the control circuits by puling the rope at various locations along the
active protection area and resetting each switch by depressing the Blue
Reset button. Ensure each time that the switches latch off and require
manual resetting by depressing the Blue Reset button. Increase the sys-
tem tension further, if required, depending upon the checks along the
active length of coverage. If fitted with a Mushroom type E-Stop button
(Red) then test and reset each switch to ensure function of control cir-
cuits. Typical operational conditions for successful operation of system
is less than 75 N. pulling force and less than 150 mm deflection of rope
between eyebolt supports. If the optional LED is fitted but is not used,
ensure that the conductors remain coiled and tied to the tie hole in the
LED flange.

5.Every week: Check correct operation of system at locations along all

coverage length. Check for nominal tension setting, re-tension rope if
necessary. Every 6 months: Isolate power and remove cover. Check
screw terminal tightness and check for signs of moisture ingress. Never
attempt to repair any switch.

(120VAC)

(120VAC)

Green

Red

(common )

Black

Red

Green

Black

(+24VDC)

(+24VDC)

Optional 24 VDC Indicator Beacon

When +24VDC is applied to the 

red

 wire, the beacon will illuminate red 

and flash.
When +24 VDC is applied to the 

green

 wire, the beacon will illuminate 

green.

Optional 120 VAC Indicator Beacon

When +120VAC is applied to the 

red

 wire, the beacon will illuminate red 

and flash.
When +120 VAC is applied to the 

green

 wire, the beacon will illuminate 

green.

(0 V)

Tension Indicator

Indicator shown with steel rope properly adjusted.

In the intere

s

t of product improvement, 

s

pecific

a

tion

s

 

a

re 

s

ubject to ch

a

nge without notice.

ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.

To convert millimeter

s

 into inche

s

, multiply by 0.03937. To convert gr

a

m

s

 into ounce

s

, multiply by 0.03527.

C

a

t. No. E51E-EN-01

E51E-EN-01+Datasheet.fm  Seite 4  Freitag, 12. Oktober 2007  11:33 11

Содержание ER1022

Страница 1: ...O auxiliary contacts satisfy the most demanding applications Vibration tolerant the snap acting switch contacts protect against nuisance tripping due to vibration Long life the ER1022 switch is designed for a min imum of one million actuations Indicator beacon the indicator beacon available in 24 VDC can be wired to flash red to indicate a tripped switch or glow a constant green to indicate a prop...

Страница 2: ...4 VDC 4 N C 2 N O 4 x M20 ER1022 042MELR Item Model Replacement Lid LED 24 VDC SM06 SL710 Rope Kit 5 m Stainless Steel RK5 Rope Kit 10 m Stainless Steel RK10 Rope Kit 20 m Stainless Steel RK20 Rope Kit 50 m Stainless Steel RK50 Rope Only 5 m R5M Rope Only 10 m R10M Rope Only 20 m R20M Rope Only 50 m R50M Rope Only 100 m R100M Rope Only 126 m R126M Tensioner Gripper Stainless Steel SM06 TG00 Eye Bo...

Страница 3: ...nimum LED Indicator Beacon 24 VDC Mechanical Mounting Any position Mounting Hardware 4 x M5 screws Actuator Travel for Positive Opening See diagrams on previous page Max Rope Span 125 m Operation Force 125 N Tensioning Force to Run Position 130 N typical Case Material Die cast aluminum alloy Eye Nut Material Stainless steel Wiring Entry 4 x M20 Weight 1100 g Color Yellow Mechanical Life 1 000 000 ...

Страница 4: ...ations along the active protection area and resetting each switch by depressing the Blue Reset button Ensure each time that the switches latch off and require manual resetting by depressing the Blue Reset button Increase the sys tem tension further if required depending upon the checks along the active length of coverage If fitted with a Mushroom type E Stop button Red then test and reset each swi...

Отзывы: