
E5CD-800
5
Specifications
Ratings
Power supply voltage
A in model number: 100 to 240 VAC, 50/60 Hz
D in model number: 24 VAC, 50/60 Hz; 24 VDC
Operating voltage range
85% to 110% of rated supply voltage
Power consumption
Models with option selection of 800:5.2 VA max. at 100 to 240 VAC, and 3.1 VA max. at 24 VAC or 1.6 W max. at
24 VDC
All other models: 6.5 VA max. at 100 to 240 VAC, and 4.1 VA max. at 24 VAC or 2.3 W max. at 24 VDC
Sensor input
Temperature input
Thermocouple: K, J, T, E, L, U, N, R, S, B, C/W, or PL II
Platinum resistance thermometer: Pt100 or JPt100
Infrared temperature sensor (ES1B): 10 to 70°C, 60 to 120°C, 115 to 165°C, or 140 to 260°C
Analog input
Current input: 4 to 20 mA or 0 to 20 mA
Voltage input: 1 to 5 V, 0 to 5 V, or 0 to 10 V
Input impedance
Current input: 150
Ω
max., Voltage input: 1 M
Ω
min.
(Use a 1:1 connection when connecting the ES2-HB/THB.)
Control method
ON/OFF control or 2-PID control (with auto-tuning)
Control
output
Relay output
SPST-NO, 250 VAC, 3 A (resistive load), electrical life: 100,000 operations, minimum applicable load: 5 V, 10 mA
(reference value)
Voltage output
(for driving
SSR)
Output voltage: 12 VDC
±
20% (PNP), max. load current: 21 mA, with short-circuit protection circuit
Auxiliary
output
Number of
outputs
2
Output
specifications
SPST-NO relay outputs, 250 VAC, 3 A (resistive load)
Electrical life: 100,000 operations, Minimum applicable load: 10 mA at 5 V (reference values)
Setting method
Digital setting using front panel keys
Indication method
11-segment digital display, individual indicators, and bar display
Character height: PV: 14.9 mm, SV: 7.1 mm
Multi SP
Up to eight set points (SP0 to SP7) can be saved and selected using the key operations, or serial communications.
Bank switching
None
Other functions
Adaptive control, automatic filter adjustment, water-cooling output adjustment, indication data (power ON time
monitor, ambient temperature monitor, and control output ON/OFF count monitors), parameter masking, operation
after power ON, manual output, heating/cooling control, loop burnout alarm, SP ramp, other alarm functions,
heater burnout (HB) alarm (including SSR failure (HS) alarm), 40% AT, 100% AT, MV limiter, input digital filter,
robust tuning, PV input shift, run/stop, protection functions, extraction of square root, MV change rate limit, logic
operations, temperature status display, simple programming, moving average of input value, and display
brightness setting
Ambient operating
temperature
−
10 to 55
°
C (with no condensation or icing),
For 3-year warranty:
−
10 to 50
°
C with standard mounting (with no condensation or icing)
Ambient operating
humidity
25% to 85%
Storage temperature
−
25 to 65°C (with no condensation or icing)
Altitude
2,000 m max.
Recommended fuse
T2A, 250 VAC, time-lag, low-breaking capacity
Installation environment
Overvoltage category II, Pollution Degree 2 (EN/IEC/UL 61010-1)
Содержание E5CD-800
Страница 19: ...MEMO 19 ...
Страница 48: ...MEMO 48 ...