Safety Precautions

Refer to 

Warranty and Limitations of Liability

.

This product is not designed or rated for ensuring 
safety of persons. Do not use it for such purpose.

To ensure safe use of laser products, do not allow the 
laser beam to enter your eye. Direct exposure may 
adversely affect your eyesight.

Do not connect an AC power supply to the Sensor. 
If AC power (100 VAC or more) is supplied to the 
Sensor, it may explode or burn.

Be sure to abide by the following precautions for the safe operation of 
the Sensor.

 Operating Environment

Do not use the Sensor in locations with explosive or flammable gas.

 Wiring

Power Supply Voltage and Output Load Power Supply 

Voltage

Make sure that the power supply to the Sensor is within the rated 
voltage range. If a voltage exceeding the rated voltage range is 
supplied to the Sensor, it may explode or burn.

Power Supply Voltage

The maximum power supply voltage is 26.4 VDC. Applying a voltage 
exceeding the rated range may damage the Sensor or cause burning. 

Load

Do not use a load that exceeds the rated load.

Load Short-circuiting

Do not short-circuit the load, otherwise the Sensor may be damaged 
or it may burn.

Connection without Load

Do not connect the power supply to the Sensor with no load 
connected, otherwise the internal elements may explode or burn. 
Always connect a load when wiring. 

Do not use the product in atmospheres or environments that exceed 
product ratings.

 Laser Warning Labels

Be sure that the correct laser warning label (enclosed) is attached for 
the country of intended use of the equipment containing the 
Photoelectric Sensor. Refer to the user's manual for details.

 Usage Environment

Water Resistance

The Sensor is rated IP67. Do not use it in water, in the rain, or 
outdoors.

Ambient Environment

Do not install the product in the following locations. Doing so may 
result in product failure or malfunction.

Locations subject to excess dust and dirt

Locations subject to direct sunlight

Locations subject to corrosive gas

Locations subject to organic solvents

Locations subject to shock or vibration 

Locations subject to exposure to water, oil, or chemicals

Locations subject to high humidity or condensation

 Designing

Power Reset Time

The Sensor is ready to operate 100 ms after the Sensor is turned ON. 
If the load and Sensor are connected to independent power supplies 
respectively, be sure to turn ON the Sensor before supplying power 
to the load.

 Wiring

Avoiding Malfunctions

If using the Sensor with an inverter or servomotor, always ground the 
FG (frame ground) and G (ground) terminals, otherwise the Sensor 
may malfunction.

 Mounting

Mounting the Sensor

If Sensors are mounted face-to-face, make sure that the optical 
axes are not in opposition to each other. Otherwise, mutual 
interference may result.

Always install the Sensor carefully so that the aperture angle range 
of the Sensor will not cause it to be directly exposed to intensive 
light, such as sunlight, fluorescent light, or incandescent light.

Do not strike the Photoelectric Sensor with a hammer or any other 
tool during the installation of the Sensor, or the Sensor will lose its 
water-resistive properties.

Use M3 screws to mount the Sensor.

When mounting the case, make sure that the tightening torque 
applied to each screw does not exceed 0.54 N·m.

Metal Connectors

Always turn OFF the power supply to the Sensor before connecting 
or disconnecting the metal connector.

Hold the connector cover to connect or disconnect it.
If the XS3F is used, always tighten the connector cover by hand. Do 
not use pliers.
If the tightening is insufficient, the degree of protection will not be 
maintained and the Sensor may become loose due to vibration. 
The appropriate tightening torque is 0.3 to 0.4 N·m.
If other commercially available connectors are used, follow the 
recommended connector application conditions and recommended 
tightening torque specifications.

WARNING

CAUTION

Precautions for Safe Use

Precautions for Correct Use

Содержание E3Z-LL

Страница 1: ...ip components on tape Long distance Sensing at 300 mm White Paper Reliable Detection of Small Objects and Narrow Gaps with the Small Spot Count bottles Detect protruding straws A Low Black White Error for Applications with Mixed Colors Compact and Reliable Laser Photoelectric Sensor Safety and reliability with laser class 1 JIS and IEC Product lineup includes models with distance setting without i...

Страница 2: ...2M Emitter E3Z LT81 L 2M Receiver E3Z LT81 D 2M Connector M8 4 pins E3Z LT66 E3Z LT86 Emitter E3Z LT66 L Receiver E3Z LT66 D Emitter E3Z LT86 L Receiver E3Z LT86 D Retro reflective with MSR function Pre wired 2 m E3Z LR61 2M E3Z LR81 2M Connector M8 4 pins E3Z LR66 E3Z LR86 Distance settable BGS Models Pre wired 2 m E3Z LL61 2M E3Z LL81 2M Connector M8 4 pins E3Z LL66 E3Z LL86 Pre wired 2 m 0 5 ms...

Страница 3: ...ng a Through beam Sensor order one Mounting Bracket for the Receiver and one for the Emitter 1 The connector will not rotate after connecting 2 The cable is fixed at an angle of 180 from the sensor emitter receiver surface Appear ance Model Quantity Remarks Appear ance Model Quantity Remarks E39 L153 1 1 Mounting Brackets E39 L98 2 1 Metal Protective Cover Bracket E39 L104 1 1 E39 L150 1 set Senso...

Страница 4: ... max Output mode switching Switch to change between light ON and dark ON Protection circuits Reversed power supply polarity protection Output short circuit protection and Reversed output polarity protection Reversed power supply polarity protection Output short circuit protection Mutual interference pre vention and Reversed output polarity protection Response time Operate or reset 1 ms max Operate...

Страница 5: ...tance Y mm 350 300 200 250 50 0 100 150 2 50 2 50 2 00 2 00 1 00 1 00 0 50 1 50 1 50 0 50 0 00 Y X Sensing object 100 100 mm white paper Distance X mm Operating range Y mm 60 50 30 40 10 20 3 3 2 2 1 1 0 Y X Sensing object 100 100 mm white paper Distance X mm Operating range Y mm 0 20 10 30 40 50 70 60 80 10000 100 1000 Distance m Excess gain ratio multiple 100 10 1 0 1 30 10 20 0 E39 R6 E39 R12 E...

Страница 6: ... board Black paper Black rubber SUS Mirror surface Material Sensing distance mm 120 100 20 60 40 80 0 White paper Veneer Card board Black paper Black rubber SUS Mirror surface Material Sensing distance mm 60 30 40 50 20 10 0 100 50 10 20 30 40 90 60 70 80 0 Spot diameter mm Dimension a Dimension b Set distance m Spot shape a b 600 300 400 500 200 100 0 1 4 0 2 0 4 0 6 0 8 1 0 1 2 0 Dimension a Dim...

Страница 7: ...is not used Brown Black Control output Blue Operation indicator Stability indicator Green Orange Load Relay Photo electric Sensor Main Circuit M8 4 pin Connector Pin Arrangement ON OFF ON OFF Operate Reset NEAR FAR Operation indicator orange Output transistor Load e g relay Between brown A and black D leads Model Operation mode Timing charts Operation selector Output circuit E3Z LT81 E3Z LT86 E3Z ...

Страница 8: ...Wire color Distance adjuster 5 turn endless Stability indicator green Operation selector Operation indicator orange Sensitivity adjuster Stability indicator green Operation indicator orange Mode selector switch Sensors with Sensitivity Adjustment and Mode Selector Switch Through beam Models E3Z LT Receiver Retro reflective Models E3Z LR Distance settable Sensor BGS Models E3Z LL ...

Страница 9: ...ction Locations subject to excess dust and dirt Locations subject to direct sunlight Locations subject to corrosive gas Locations subject to organic solvents Locations subject to shock or vibration Locations subject to exposure to water oil or chemicals Locations subject to high humidity or condensation Designing Power Reset Time The Sensor is ready to operate 100 ms after the Sensor is turned ON ...

Страница 10: ...ator may turn off in reaction to reflection from background objects In such cases incline the Sensor by 10 as shown in the illustration for more stable detection Adjusting Distance settable Models Indicator Operation Note If the stability indicator is lit the detection no detection status is stable within the rated ambient operating temperature 10 to 55 C Inspection and Maintenance Cleaning Never ...

Страница 11: ...tter E3Z LT 1 L 12 20 20 3 2 8 25 4 12 7 2 1 31 31 10 8 10 8 Two M3 11 Stability indicator green Sensitivity adjuster Operation selector Lens Receiver E3Z LT 1 D 4 5 11 2 7 5 20 20 3 2 8 25 4 12 7 2 1 31 31 10 8 10 8 Operation Indicator orange 4 dia vinyl insulated round cable with 3 conductors Conductor cross section 0 2 mm2 AWG24 Insulator diameter 1 1 mm Standard length 2m Through beam Standard...

Страница 12: ... section 0 2 mm2 AWG24 Insulator diameter 1 1 mm Standard length 2m Retro reflective Models Pre wired Models E3Z LR61 E3Z LR81 Retro reflective Models Standard Connector Models E3Z LR66 E3Z LR86 M8 connector 9 75 4 5 11 2 7 5 20 20 16 7 2 8 25 4 3 10 8 10 8 10 4 2 1 31 31 Emitter Lens 2 5 dia 8 Stability indicator green Receiver Lens 7 dia Sensitivity adjuster Operation selector Operation Indicato...

Страница 13: ...er 1 1 mm Standard length 2 m and 0 5 m 2 1 31 31 8 10 8 10 8 18 7 BGS Models Pre wired Models E3Z LL61 E3Z LL81 E3Z LL63 E3Z LL83 Two M3 M8 connector Operation Indicator orange Set distance adjuster Operation selector Stability indicator green 10 4 9 75 Receiver Lens 7 dia Emitter Lens 2 5 dia 25 4 2 8 20 20 3 2 1 31 31 8 10 8 10 8 8 4 12 7 3 18 7 BGS Models Standard M8 Connector Models E3Z LL66 ...

Страница 14: ...ear surface ABS 34 40 3 52 59 9 2 7 8 1 6 7 5 Two 3 5 dia 7 Reflector E39 R6 34 40 52 60 3 5 4 8 Two 3 5 dia Materials Reflective surface Acrylic Rear surface ABS 37 R3 7 23 30 23 45 5 5 2 9 R3 7 Two 3 4 dia Reflector E39 R12 Materials Reflector Polycarbonate surface Acrylic interior Frame ABS Cat No E850 E1 01 In the interest of product improvement specifications are subject to change without not...

Страница 15: ...ther in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted Suitability of Use Omron Companies shall not be responsible for conformity with any standards codes or regulations which apply to the combination of the Product in the Buyer s application or use of the Product At Buyer s request Omron will provide applicable third party cer...

Страница 16: ...Mouser Electronics Authorized Distributor Click to View Pricing Inventory Delivery Lifecycle Information Omron E3Z T61 L E3Z T81 D 2M E3Z LT66 E3Z LL68 E3Z LL88 E3ZLT81D2M ...

Отзывы: