manualshive.com logo in svg
background image

© 

OMRON Corporation 2011 All Rights Reserved. 

Digital Fiber Sensor

RUN

SET

Teaching

0. Operation Mode

Light-ON

Dark-ON

Switch to SET mode.

1. Detection Mode

Set separately for each channel.

Set separately for each channel.

2. Timer Function

Note: Refer to 7. Basic Settings for teaching methods.

Zero reset

Switch to RUN mode. 

Switch to RUN mode.

Switch to RUN mode.

Switch to RUN mode.

The display will be zeroed, 

i.e., the conformity will be 

displayed as 0.

RUN

SET

RUN

SET

RUN

SET

Press the MODE key for 

3 seconds or more. 

RUN

SET

KeyLock

+

+

+

Light level

Threshold

LOC

ON

LOC

OFF

Standard mode

High-resolution mode

High-speed mode

8. Detailed Settings

9. Convenient Functions

T

“Light lerel/Threshold”

“TECH/Threshold”are displayed in fixed time.

E3X-DA

□□

-S

Instruction Sheet

Thank you for selecting OMRON product.This sheet primarily describes precautions
required in installing and operating the product.
Before operating the product, read the sheet thoroughly to acquire sufficient knowledge
of the product. For your convenience, keep the sheet at your disposal.

Super-high-speed mode

Set separately for each channel.
Setting range: 0P to 99P
If the teaching level is small or large, it is set to 
upper or lower of threshold to operate correctly.

Hold down the MODE key and 

press the DOWN key 

for 3 seconds or more. 

Frash twice and the zero 

reset function will be cleared.

The light level displayed on the main display can be zeroed. The threshold displayed in 

the sub-display is shifted by an amount corresponding to the amount the light level was 

changed. Confirm that the MODE key setting is 0RST (zero reset) in advance.

Setting Method

Clearing Method

Key operations can be disabled to help prevent key operating errors.

Setting Method

Clearing Method

Flash twice and key input 

will be enabled.

Flash twice and key input 

will be disabled.

If a key is pressed while key operations are locked, 

"LOC ON" will flash twice on the display to indicate 

that key operations have been disabled.

User Save

RUN

SET

Save has been completed.

Not save

NO?

YES?

Save

Switch to SET mode.

Press the MODE key and  the UP key 

at the same time for 5 seconds or more.

SAVE

NO?

GOOD

Setting Method

+

The current setting can be saved. 

Threshold

GOOD

Threshold

Initial Reset, User Reset

RUN

SET

Initialization has been 

completed.

Not initialized

NO?

YES?

Initialized

Switch to SET mode.

Press the UP key and the DOWN key for 5 seconds or more.

+

INIT

NO?

Setting Method

Initial reset: Initialize all of settings (except user save) to return to the default states. 

User reset: Return to the saved states.

1) When user save is not executed(Initial reset only)

RUN

SET

User reset

USER

INIT

Initial reset

Switch to SET mode.

Press the UP key and the DOWN key for 5 seconds or more.

+

RST

USER

USER

Setting Method

2) When user save is executed(Select initial reset or user reset)

GOOD

Threshold

User reset has been 

completed.

Not execute 

user reset

NO?

YES?

Execute 

user reset

Refer to 1) 

When user save 

is not executed.

NO?

ERR

EEP

10. Error display

If the error occurs, the error messages are blinking as below. 

In these case Execute following procedures to restore.

OVER

CUR

EEPROM error

Execute initial reset operation.

The following functions can be set in SET mode. The function displays are the default 

settings. All settings except for the operation mode, detection mode, timer function, teaching 

level setting and ACT setting are the same for both channels .

: The  values shown for thresholds, light level, ratio, etc., are examples only. Actual displays may vary.

Overcurrent of control output

Check an output load and keep current in rating.

Check whether the load to be short-circuited.

Power supply 

connector

Protector seal

Precautions for Correct Use

Precautions for Safe Use

1)Do not use the Amplifier Unit in environments subject to flammable or explosive gases.

2)Do not use the Amplifier Unit in environments subject to exposure to water, oil, chemicals, etc.

3)Do not attempt to disassemble, repair, or modify the Amplifier Unit in any  way.

4)Do not apply voltages or currents that exceed the rated ranges.

5)Do not use the Amplifier Unit in atmospheres or environments that exceedproduct ratings.

6)Wire the Amplifier Unit correctly, e.g., do not reverse the polarity of the power supply.

7)Connect the load correctly.

8)Do not short both ends of the load.

9)Do not use the Amplifier Unit if the case is damaged.

10)When disposing of the Amplifier Unit, treat it as industrial waste.

11)Do not use the sensor in the place exposed to the direct sunlight.

1)Do not use the Amplifier Unit under the following conditions.

In the place exposed to the direct sunlight.

In the place where humidity is high and condensation may occur.

In the place where corrosive gas exists.

In the place where vibration or shock is directly transmitted to the product.

2)Wire the Amplifier Unit separately from power supply or high-voltage lines. 

If the Amplifier Unit wiring is wired together with or placed in the same duct 

as high-power lines, inductive noise may cause operating errors or damage the Amplifier Unit.

3)For extending wires,use a cable 0.3mm min., and 100m max. in length.

When using the cable as a Korea’s S-mark certified product, use the cable of less than 10m 

in length.

4)Do not extend the follwing force values applied the cable.Tensile:40 N max.,torque:0.1 Nm 

   max.,pressure:20 N max.,flexure:3 kg max.

5)The Amplifier Unit is ready to operate 200 ms after the power supply is turned ON. If the 

    Amplifier Unit and load are connected to power supplies separately, turn ON the power supply 

    to the Amplifier Unit first.

6)Please turn on the power supply at the same time when you connecting use the amplifier units 

    with cables.

    Mutual interference prevention might not operate normally or mobile console might not be able 

    to be used when the difference between connected amplifiers at the power supply turning on 

    time is 30ms or more.

7) Depending on the application environment, time may be required for the light level to 

    stabilize after the power supply is turned ON.

8)Output pulses may occur when the power is interrupted, so turn OFF the ower to the load or 

   load line before turning OFF the power to the Sensor.

9)When you use the Amplifier Units with Connectors, 

to prevent electric shock or short-circuits, attach 

the protector seals provided with E3X-CN-series 

Connectors to the sides of power supply 

connectors that are not being used.

10)Always turn OFF the power supply before connecting, 

separating, or adding Amplifier Units.

11)Do not pull or apply excessive pressure or force 

(exceeding 9.8 N

m) on the Fiber Unit when it is 

mounted to the Amplifier Unit.

 12) Mobile console E3X-MC11-SV2 doesn't correspond to the new feature such as tough mode 

     and ON delay OFF delay timer now. E3X-MC11-S cannot be used.

 13)Optical communication are not possible with the E3X-DA-N. 

     Optical communication are possible with the E3X-DA-S or the E3X-MDA.

 14)Always keep the protective cover in place when using the Amplifier Unit.

 15)Do not use thinners, benzine, acetone, or kerosene for cleaning the 

Amplifier Unit.

Confirming the Package Contents

OVER

flash twice

flash twice

LO

Over error

Low error

 Teaching Error

After execute teaching, when the following is displayed on sub digital display, the error 

has occurred. Deal referring to the following. 

The incident light level is too 

large.

After decrease the light level by the power tuning, execute re-teaching.

After adjust the Fiber Unit to decrease the incident light level, 

execute 

re-teaching.

The incident light level is too small.

After setting the detection method at a slower response time, 

execute 

re-teaching.

After adjust the Fiber Unit to increase the incident light level, 

execute 

re-teaching.

Setting

Display

Switch to RUN mode.

RUN

SET

Threshold

Light level

1)Manual Setting

Adjust the threshold with the 

UP key or the DOWN key.

The display set by the display 

switch will return in 

approximately 5 seconds.

DIN Track

1

2

DIN Track

Hook on the Fiber Unit connector end

1

2

4

3

5. Installing the Amplifier Unit

6. Connecting the Fiber Unit

1. Open the protective cover

2. Press up the lock button.

3. Insert the fiber unit all the way to the back of the 

connector insertion opening.

4. Return the lock button to its original position 

to secure the fiber unit.

 Mounting Units

Catch the hook on the Fiber Unit connector end of the 

Unit on the DIN Track and then press down on the 

other end of the Unit until it locks into place.

Always attach the Fiber Unit connector end first. 

If the incorrect end is attached first, the mounting

strength will be reduced.

Removing Units

Press the Unit in the direction indicated by "1" 

and then lift up on the Fiber Unit connector end 

of the Unit in the direction indicated by "2."

Joining Amplifier Units (for Units with Connectors)

Up to 16 Units can be joined.

1. Mount the Amplifier Units one at a time onto the 

    DIN Track.

2. Slide the Amplifier Units together and press the 

    Amplifier Units together until they click into place.

Secure the Units with an End Plate (PFP-M) if 

there is a possibility of the Amplifier Units moving, 

e.g., due to vibration.

Remove the Units in the reverse order.

4. Nomenclature

(Unit: mm)

(Pre-wired Models)

3. Dimensions

10

4.5

5.65

18.7

36.7

3.4

9.9

4.3

70

44.3

8.1

32

12.5

12.15

15.1

29.8

32.8

3.9×3=11.7

3.9×3=11.7

Tw

o,2.4 dia.

1. Ratings and Specifications

2. I/O Circuits

12 to 
24 VDC

Brown

Orange

Blue

12 to 
24 VDC

Brown

Orange

Blue

External 
input *

External 
input *

E3X-DA21-S, E3X-DA7-S,E3X-DA0-S

NPN models

E3X-DA51-S, E3X-DA9-S

PNP models

Internal circuits

Internal circuits

Load

Load

Load

Load

Black

Black

Pink

Pink

Output for 
channel 1

Output for 
channel 1

Output for 
channel 2

Output for 
channel 2

• 

Amplifier Unit: 1      

• 

Instruction Sheet (this sheet): 1

Hold down the MODE key 

and press the UP key 

for 3 seconds or more. 

Hold down the MODE key 

and press the UP key 

for 3 seconds or more. 

Press the MODE key

Switch the UP key or DOWN key

0RST

OFF

 

Operation indicator for channel 2 (orange)

 

Channel selector

1

2

UP

S E T

RUN

1

2

DOWN

MODE

 

Lock button

 

Operation indicator 

     for channel 1 (orange)

 

Main display (red)

 

Sub-display (green)

 

Operation keys

 

SET/RUN switch

SET            Select for various settings or teaching.

Mode 

 

                                       Description

RUN            Select for operating, threshold value adjusting or various executings.

 

Used to connect and disconnect the Fiber Unit.

UP key

Increases the threshold or threshold 

ratio.

Depends on the setting.

• Executes teaching.

• Changes the setting forward.

Decreases the threshold or threshold 

ratio.

Switches the function to be set on the 

display.

DOWN key

MODE key

Key

Function

RUN mode

SET mode

Depends on the setting.

• Executes teaching.

• Changes the setting in reverse.

Execute variously depends on the MODE 

key setting.

LON (light-ON)

Selection 

 

Description

DON (dark-ON)

RUN

SET

Switch to RUN mode.

Tuning completed and previous display returns.

Main Display

Press the MODE key for at least 3 seconds.

Power tuning target value

PTUN

During power tuning

Progress bar

PTUN

The output will turn ON when the incident light level is above the threshold.

If DIFF (differential operation) is set for the detection method, the output will turn 

ON when an edge is detected.

The output will turn ON when the incident light level is below the threshold.

If DIFF (differential operation) is set for the detection method, the output will turn 

OFF when an edge is detected.

Confirm that the MODE key setting is PTUN (power tuning) in advance. 

A progress bar will appear on the 

sub-display one digit at a time. 

(Release the MODE key when the progress 

bar appears.)

Display 
alternates at a 
fixed interval.

Select either light-ON or dark-ON operation.

Set as the operation mode in SET mode. Refer to 8. Detailed Settings. 

Power tuning can be used to adjust the incident light level that is currently being received to the power tuning target 

value (default: 2,000). Before tuning ON the power, always secure the detection object and Head and be sure that the 

incident light level is stable.

Setting Method

The power tuning target value can be changed. Refer to 8. Detailed Settings.

7. Basic Settings

1. Setting the Operation Mode

2. Adjusting the Power (as Required)

Setting

Display

Setting

RUN
mode

SET
mode

Display

Power tuning Errors

An error has occurred if one of the following displays appears after the progress bar is displayed.

Over Error

The incident light level is too low for the power tuning target value. 

The power can be increased up to approximately 5 times the incident 

light level without power tuning.

PTUN

OVER

Switch to RUN mode

Bottom Error

The incident light level is too high for the power tuning target value. 

The power can be decreased down to approximately 1/20th the incident light 

level without power tuning.

PTUN

BOTM

PTUN

OFF

RUN

SET

Hold down the MODE key and press the DOWN key for at least 3 seconds. 

Note: Press the DOWN key right after pressing the MODE key.

Flashes twice

Flashes twice

+

Clearing Method

Effective set for ATC function

Switch to RUN mode.

Switch to RUN 

mode.

Press the MODE key 

for at least 3 seconds.

The sub-display will flash.

The threshold value 

that was set will flash 

twice.

Press the UP or 

DOWN key.

Press the UP or 

DOWN key.

Press the MODE key 

for at least 3 seconds.

Switch to SET 

mode.

With a workpiece

Without a workpiece

RUN

SET

Threshold 

ratio

Light level 

Threshold 

ratio

Workpiece

Threshold value

The threshold ratio is adjusted or the threshold is updated by the incident level every about 3 seconds by ATC start.  

Confirm that the MODE key setting is ATC in advance.

2

) Teaching

2-point teaching

Teaching can be performed twice, once with and once without a workpiece, and the value between   

the two measured values is set as the threshold. RUN mode and SET mode – each mode can be set up.

ATC

TECH

2PNT

Adjust the threshold ratio 

value with the UP and 

DOWN keys .

The threshold value that was set will 

flash twice.

Press the MODE key at least 3 

seconds.

RUN

SET

RUN

SET

Switch to RUN 

mode.

RUN

SET

If DIFF (differential operation) is set for the detection method, the threshold value 

will be set to half of the difference between the two measured values.

3. Setting Thresholds

Setting

Display

AUTO

Threshold 

value

AUTO

Light level

Automatic-teaching(It sets up at move work.)

While continuing pushing a key, the middle of the detected maximum and the minimum value can be 

set up as a threshold. Confirm that the MODE key setting is AUTO in advance.

Pushing the MODE key 

during 3 seconds or more 

It is displayed on a sub digital 

value as AUTO, and the 

sampling of right level is 

effective.

Threshold value will flush twice.

This method cannot be used to set the threshold when the detection method has 

been set to DIFF (differential operation).

Setting

Display

Switch to RUN mode.

Without a workpiece

Press the UP or DOWN key .

The sub-display will flash.

The threshold value that was 

set will flash twice.

RUN

SET

Switch to RUN mode.

RUN

SET

Teaching for Through-beam Sensor Heads 

It is performed without a workpiece. The threshold  will be set to lower with ratio in the teaching 

level setting for the light level of no workpiece.  Refer to 8. DetailedSetings.

TECH

THRU

Threshold 

value

If DIFF (differential operation) is set for the detection method, the threshold value will 

be set to the minimum value that can be detected with stability for the light level of the 

without worlpiece.

Setting

Display

Remove a workpiece

3 seconds

Switch to RUN mode.

SET

Switch to RUN 

mode.

RUN

SET

TECH

RFCT

Threshold 

value

 

Teaching for Reflective Sensor Heads

It is performed without a workpiece (i.e., for the background). The threshold  will be set to upper 

with ratio in the teaching level setting for the light level of no workpiece. Refer to 8. DetailedSetings.

Press the UP or 
DOWN key .

Press the UP or DOWN key for 
at least 3 seconds.

The sub-display will flash 
twice.

The threshold value that was set 
will flash twice.

If DIFF (differential operation) is set for the detection method, the threshold value will 

be set to the minimum value that can be detected with stability for the light level of the 

without worlpiece.

Setting

Display

Switch to SET mode.

RUN

SET

Switch to RUN mode.

RUN

SET

Threshold 

value

FULL

 

Setting the Threshold at the Maximum Sensitivity

The threshold can be set at the maximum sensitivity. This is convenient when using the longest 

sensing distance. 

Press the UP or DOWN key for at 
least 3 seconds.

The threshold value that was set 
will flash twice.

Execute it by the without workpiece. 

The value that is set will depend on the detection method and power tuning settings.

1

2

 

Lit when the output for channel 1 is ON.

 

Displays the incident light level,the function name or the change in the incident light lerel.

 

Lit when the output for channel 2 is ON.

 

Display the threshold, the setting of the function displayed on the main disply or threshold ratio.

 

Used to switch the mode.

 

Used to select the channel to display or set.

 

Used to change the display or set functions.

Tough mode

Differential operation mode

Operation is according to the change 

in the incident light level.The output 

for channel 2 is always an alarm 

output for the absolute light level.

1-ms increments

1 to 20 ms

5-ms increments

20 to 200 ms

100-ms increments

200 to 1000 ms

1000-ms increments

1000 to 5000 ms

Single edge

Either the rising or falling 

edge is detected.

Double edge

Both the rising and falling 

edge are detected.

250 ms

500 ms

500 ms

1 ms

1 ms

2 ms

10 ms

20 ms

100 ms

200 ms

Single edge

This setting depends on the setting for 

the differential edge selection.

Setting range: 1 to 5,000

Double edge

Not

Not                    ,

Differential 
Edge Selection

Differential 
Response Time

Timer Time

Timer disabled.

OFF-delay timer

ON-delay timer

One-shot timer

----

OFFD

ON-D

1SHT

ONOF

On-delay OFF-delay timer

ON-delay

Timer

OFF-delay

Timer

3. Teaching Level

    Setting

Disable ATC.

ON

OFF

ATC function is effective.

Set separately for each channel.

4. ACT Setting

Not

Maximum power

FULL

Setting range: 100 to 3,900, FULL

The function of the MODE key in RUN mode can be selected.

5. MODE Key 
    Setting

The information displayed in RUN mode can be selected. 

When going to SET mode, this setting will be ignored and 

the incident light level and threshold value will be displayed.

6. Display
      Switch

Light level

PEAK

Light level

Channel

The incident light level 

and the channel.

Light level

Threshold

% light level Threshold

L-PE

D-BT

Detection status

Alternates at 

a fixed interval

PEAK

BOTM

Peak level

Bottom level

The current incident 

light level and the peak 

incident light level.

The incident light level 

and threshold value

The incident light level as a 

percentage of the threshold value 

and the threshold value.

The peak incident level and 

bottom incident level of fixed 

time(2s).

The incidient light peak level 

and no incident light bottom 

level.
Analog bar display. The 

current detection status is 

displayed as an analog bar. 

The bar will lengthen from the 

right as ON status is reached.

Tunes the power.

2-point teaching.

Automatic-teaching.

PTUN

0RST

Executes a zero reset.

2PNT

AUTO

ATC

Executes.

Normal display.

D123

321D

Reversed display.

7. Display 

    Orientation

The function of the output for channel 2 can be selected.

9. Output Setting

The output for channel 1 functions according to the 

detection mode selection.

This setting is not value if DIFF (differential operation) 

is set for the detection method. (The output for channel

2 is always an alarm output for differential operation.)

Output for each channel

2OUT

AREA

Output if level is between the two 

thresholds.

SELF

Self-diagnosis output

Output when the incident light level 

is not stable, i.e., when the light level of 1CH is ±10% of 

the threshold value for 300 ms or longer.

The item that is controlled by the input from an external device 

can be selected.

Through-beam, no-workpiece teaching

THRU

RFCT

Reflective, no-workpiece teaching

2PNT

2-point teaching

AUTO

Automatic teaching

10. External
       Input Setting *

PTUN

Power tuning

0RST

Zero reset

LOFF

Light OFF (The light will remain OFF as 
long as the input is ON.)

ATC

ATC start 

The teaching cannot be executed even.

8. Eco Mode Setting

Effective Pulse Widths

0.1 to 2 s

Executing: 0.1 to 2 s
Clearing: 3 s or longer

Effective ON pulse 
width: 0.1 s min.

Selection

Pulse width

,

,

Effective  pulse 
width: 3 s 

OFF

ECO1

Standard brightness.

Dims the display.

Turns off the display.

ECO2

D

C

D

C

When DIFF is selected for detection method ,ACT 

function is diasabled.

B

A

LON

DON

A

B

STND

HRES

DIFF

SHS

HS

TG

*1: Both the E3X-CN21 Master Connector (4-conductor) and the E3X-CN22 Slave Connector (2-conductor) can be used.

*2: Communications and mutual interference prevention does not function if super-high-speed mode is selected

for the detection mode.

*3: Mutual interference prevention can be used for only up to 6 Units if power tuning is enabled.

*4: Sensing distance is about 1/2 and light level is about 1/3 when the eco-mode is effective. 

Model               NPN

                          PNP              

Control output quantity

External input quantity

Connection  method

Light source

(emission wavelength)

Power supply voltage

Power consumption

Control output

External input 

Protection circuits

Response     Super-high-

time             speed mode

                    High-speed 

                    mode

                    Standard mode

                    High-resolution

                    mode

                    Tough mode

Sensitivity setting

Functions    Power tuning

                    Differential

                    detection

 

                    Timer

                    

Auto power control

                    ATC

                    Zero reset

                    Setting reset

                    Mutual interference

                    prevention

                    Eco mode

                    Output setting

                    External input 

                    settings

 

2

1

Load power supply voltage: 26.4 VDC max.; NPN/PNP open collector;

load current: 50 mA max.; residual voltage: 2 V max. off-stage current: 10µA max.

Operating:Groups of 1 to 2 Amplifiers: −25°C to 55°C

Groups of 3 to 10 Amplifiers: −25°C to 50°C

Groups of 11 to 16 Amplifiers: −25°C to 45°C

Storage: −30°C to 70°C (with no icing or condensation)

Operating and storage: 35% to 85% (with no condensation)

20 M

Ω

 min. 

(at 500 VDC)

1,000 VAC at 50/60 Hz for 1 minute

Destruction: 10 to 55 Hz with a 1.5-mm double amplitude

for 2 hours each in X, Y and Z directions

IEC 60529 IP50 (with Protective Cover attached)

       

Approx. 100 g                            Approx. 55 g                                       Approx. 55 g

Polybutylene terephthalate (PBT)

Polycarbonate (PC)

Operate or reset: 80 µs

Operation indicator for channel 1 (orange), Operation indicator for channel 2 (orange)

E3X- DA21-S 

E3X- DA7-S 

E3X- DA51-S 

E3X- DA9-S 

Pre-wired

2

Wire-saving connector

No-voltage input

Normal: 960 mW max. 

current consumption: 40 mA max. at power supply voltage of 24 VDC, 

80 mA max. at power supply voltage of 12 VDC

ECO1

720 mW max. 

current consumption: 30 mA max. at power supply voltage of 24 VDC, 

60 mA max. at power supply voltage of 12 VDC

ECO2

600 mW max. 

current consumption: 25 mA max. at power supply voltage of 24 VDC, 

50 mA max. at power supply voltage of 12 VDC

Red LED(625nm)

12 to 24 VDC ±10%, ripple (p-p) 10% max.

Power supply reverse polarity protection, Output short-circuit protection and Output 

reverse polarity protection.

Incandescent lamp: 10,000 lux max., Sunlight: 20,000 lux max.

Initial reset or user reset

Possible for up to 10 Units

Light level+Threahold, Light level ratio+Threshold, 

Peak light level+Bottom light level,

Incident peak light level+No incident bottom light level, Analog bar display, 

Light level+Peak light level, Light level+Channel number

7-segment displays (Main display: Red, Sub-display: Green), 

display direction can be reversed.

Off, Eco1 or Eco2

Output for each channel, Area output or Self-diagnosis output

Various teachings, automatic teaching, power tuning, zero reset, 

light emission OFF or ATC start 

Threshold updates at intervals of about 3 s

Negative values can be displayed (Threshold value is shifted, too)

No effect, OFF delay, ON delay, one-shot or ON delay OFF delay

Timer time: 1ms to 5s (variable)

Teaching (2-point teaching, teaching for though-beam sensor heads, 

teaching for reflective sensor heads,setting the threshold at the maximum sensitivity,

positioning teaching or automatic-teaching) or munual adjustment

Light emission power and reception gain, digital control method

Switchable between single edge and double edge detection mode

Single edge: 250µs, 500µs, 1ms, 10ms or 100ms

Double edge: 500µs, 1ms, 2ms, 20ms or 200ms

Light level

Light level

*3

*1

*2

Light level

* Only E3X-DA21-S and E3X-DA51-S

If SHS is set for the detection method, the power tuning target value will be not have effect

and the power will be set to the minimum value.

The light level might change when the detection method is changed. 

In that case, execute the power tuning again after changing the detection method. 

Without the workpiece

ATC-Start is performed at the time of a 
power supply injection.

ON

OFF

Disable counter.

The processing executed when the power supply is turned 

on is selected.

Setting at power

supply ON

PTAT

Power tuning and ATC-Start is performed
at the time of a power supply injection.

The display turns on the key operation when the Eco-mode is effective. 

It returns to the Eco-mode if there is no key operation for ten seconds. 

Not

Maximum power

FULL

Setting range: 100 to 3,900, FULL

This method cannot be used to set the threshold when the detection method has been set to 

DIFF (differential operation).

Positioning-teaching

It executes it puts on the place where it wants to position workpiece. 

Setting

RUN
mode

Switch to RUN 

mode.

Press the MODE key 

for at least 3 seconds.

Press the MODE key 

for at least 3 seconds.

Workpiece

RUN

SET

Workpiece

Refer to 

2-point teaching for SET mode and display.

Operate or reset: 250 µs

Operate or reset: 1 ms

Operate or reset: 16ms

Operate or reset: 4 ms

Indicator

Digital switch

Digital display

Ambient illumination

(Receiver side)

Ambient temperature

Ambient humidity

Insulation resistance

Dielectric strength

Vibration resistance

Shock resistance

Degree of protection

Weight (packed state)

Materials     Case

                 Cover

High-speed control method for emission current

*4

RUN

OMRON Corporation

Suitability for Use

EUROPE

OMRON EUROPE B.V. Sensor Business Unit

Carl-Benz Str.4, D-71154 Nufringen Germany

Phone:49-7032-811-0  Fax: 49-7032-811-199
NORTH AMERICA

OMRON ELECTRONICS  LLC

One Commerce Drive Schaumburg,IL 60173-5302 U.S.A.

Phone:1-847-843-7900  Fax : 1-847-843-7787
ASIA-PACIFIC

OMRON ASIA PACIFIC PTE. LTD.

No. 438A Alexandra Road #05-05-08(Lobby 2),

Alexandra Technopark, Singapore 119967 

Phone : 65-6835-3011  Fax :65-6835-2711

o

THE PRODUCTS CONTAINED IN THIS SHEET ARE NOT SAFETY RATED.  
THEY ARE NOT DESIGNED OR RATED FOR ENSURING SAFETY OF 
PERSONS, AND SHOULD NOT BE RELIED UPON AS A SAFETY 
COMPONENT OR PROTECTIVE DEVICE FOR SUCH PURPOSES.
Please refer to separate catalogs for OMRON's safety rated products.

OMRON shall not be responsible for conformity with any standards, codes, or 
regulations that apply to the combination of the products in the customer's 
application or use of the product. 
 
Take all necessary steps to determine the suitability of the product for the 
systems, machines, and equipment with which it will be used.
Know and observe all prohibitions of use applicable to this product.
 
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING 
SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE 
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, 
AND THAT THE OMRON PRODUCT IS PROPERLY RATED AND 
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL 
EQUIPMENT OR SYSTEM.
See also Product catalog for Warranty and Limitation of Liability.

CHINA

OMRON(CHINA) CO., LTD. 

Room 2211, Bank of China Tower,

200 Yin Cheng Zhong Road, 

PuDong New Area, Shanghai, 200120, China

Phone : 86-21-5037-2222  Fax :86-21-5037-2200

OCT, 2009

E3X- DA0-S 

2

Connector for communication unit

The sub-display will flash twice and power tuning will be cleared.

*E3X-DA0-S: Refer to E3X-CRT Operation Manual (E412-E1-01)or E3X-ECT Operation Manual(E413E1-01). 

 

Destruction: 10 to 150 Hz with a 

0.7

-mm 

double amplitude,50m/s² max.acceleration 

for 80min each in X, Y and Z directions

Destruction: 500 m/s²

3 times each in X, Y and Z directions

Destruction: 200 m/s²

2 1 6 6 9 3 6 - 3 A

LOC

ON

Precaution on Safety

Meanings of Signal Words

Alert statements in this Manual

CAUTION

NOTICE:

This is a class A product. In a domestic environment this product may cause 

radio interference in which case the user may be required to adequate measures.

Indicates a potentially hazardous situation which, if not avoided, 

May result in minor or moderate injury or in property damage.

Do not connect sensor to AC power supply.

Risk of explosion.

Do not use it exceeding the rated voltage. 

There is a possibility of failure and fire.

CAUTION

Write results to EEPROM.

ON

OFF

Do not write results to EEPROM.

Whether external input execution results are written 

to EEPROM can be selected. Disable this function 

if the external input is turned ON frequently. 

(The write life is approximately 100000 writes.)

11. External Input 

     Memory *

* The external input cannot be used though it is displayed 

   even by the wire-saving connector

Standard models

Manufacturer:

  Omron Corporation,

  Shiokoji Horikawa, Shimogyo-ku,

  Kyoto 600-8530 JAPAN

  Shanghai Factory

  No.789 Jinji Road,

  Jinqiao Export Processing District,

  Pudong New Area,Shanghai,201206 CHINA

  

TRACEABILITY INFORMATION:

Representative in EU:

  Omron Europe B.V.

  Wegalaan 67-69

  2132 JD Hoofddorp,

  The Netherlands

Отзывы: