Label Sensors

2. E3U-GLK3_

Installation

Connect the sensor to the operating voltage (+). The Power LED 
(green) lights up. Insert the label material and gently push down. 

During the teach process do not remove the label material from 
the detection area. 

Manual auto-teach:

Press the teach key for min. 2 sec., until the status LED (yellow) 
shows a continuous signal.

The auto-teach procedure is now active indicated by a fast flash-
ing Status LED. Move the labels through the slot. The auto-teach-
ing takes 2-10 seconds depending on the complexity of the 
labels. During the auto teach procedure min. 2 labels should be 
pulled through. For higher stability the number of labels that are 
pulled through should be as high as possible.

The result of the auto-teach procedure is indicated by the Status 
LED and Power LED: 

• Status LED and power LED flashing 2x: auto-teach procedure 

successful. The sensor automatically switches into run mode.

• Status LED and power LED flashing 4x: Auto-teach proce-

dure not successful. Repeat the auto-teach procedure.

Remote auto-teach:

For remote auto-teach connect pin 2 (white wire) to the operating 
voltage (+). The Status LED starts flashing quickly. Move the la-
bels through the slot. 
The result of the remote auto-teach procedure is indicated by the 
Status LED and Power LED as described before.
If pin2/white wire is not connected the sensor operates in run 
mode.
If pin2/white wire is connected to ground the sensor is locked (no 
manual auto-teach possible)

Exchanging the bottom part for E3U-GLK3_

For the detection of labels using the capacitive sensors E3U-
GLK3_, it is important that the label is firmly guided by the bottom 
part.
To ensure a smooth guiding of larger labels up to 215 mm remove 
the pre-mounted bottom part and replace by exchangeable bot-
tom part. For labels up to 175 mm depth use the E3U-GLK-EB1 
and for labels up to 215 mm use the E3U-GLK-EB2. Attach the 
bottom part again. The maximum mounting torque for the screws 
is 0.8 Nm.
Refer to Operating Instructions to teach the sensors again.
The bottom parts are sold separately.

Cleaning

To clean the sensor and the bottom part remove any residues of 
labels with a plastic scraper and residues of adhesion with alco-
hol.

2-10 

s

min. 2x

min. 2

s

Power LED (green)

Status LED (yellow)

Содержание E3U-GL

Страница 1: ...xact positioning without re adjust ment Features Stable operation and quick set up Stable operation eliminates the need to re adjust the sensor due to temperature changes or other influences during pr...

Страница 2: ...CuZn PVC 2 m PUR 2 m XS2F M12PVC3S2M XS2F M12PUR3S2M XS2F M12PVC3A2M XS2F M12PUR3A2M 4 wire PVC 2 m PUR 2 m XS2F M12PVC4S2M XS2F M12PUR4S2M XS2F M12PVC4A2M XS2F M12PUR4A2M Item E3U GL1 E3U GL2 E3U GLK...

Страница 3: ...re pulled through should be as high as possible For E3U GL1 For E3U GL2 The result of the auto teach procedure is indicated by the Status LED LED flashing 2x auto teach procedure successful The sen so...

Страница 4: ...Remote auto teach For remote auto teach connect pin 2 white wire to the operating voltage The Status LED starts flashing quickly Move the la bels through the slot The result of the remote auto teach...

Страница 5: ...U GLK32 M1 1 2 4 3 Brown Black White Blue 10 to 35VDC 0V NPN PNP Teach Lock 1 2 4 3 Brown Black White Blue 10 to 35VDC 0V NPN PNP 1 2 4 3 M8 Connector Pin Arrangement 1 4 2 3 Brown Black White Blue 10...

Страница 6: ...E3U GLK31 M1 E3U GLK32 M1 Status LED yellow Power LED green Teach M8 x 1 29 5 11 12 28 14 M5 100 5 5 19 35 102 5 120 5 M8x1 Status LED Status LED Teach NO NC Teach M3 x 10 max 0 8 Nm Power LED Status...

Страница 7: ...rises de pending on application conditions such as the surrounding tem perature and the power supply voltage Use caution when operating or washing the Sensor Do not use the Sensor in any atmosphere o...

Страница 8: ...be suitable for the products Outdoor use uses involving potential chemical contamination or electrical interference or conditions or uses not described in this document Nuclear energy control systems...