Rating/performance

Characteristic data (typical)

Operating Range

E3S-R11, E3S-R61+ E39R1

Changes in light intensity when detecting various transparent
objects (Note 1)

The following are the permeation rates of a various transparent
objects on condition that a permeation rate of 100 means that
there is no object within the sensing distance of the E3S-R. The
permeation rate of any type of object sensed by the E3S-R must
be as low as possible for the stable sensing of the object. Before
using the E3S-R to sense objects, use samples of the objects to
check if the E3S-R can sense the samples easily.

Note: 1 . The sensing distance of each model was set to the rated sensing dis-

tance.

2 . The permeability values were checked with light with a wavelength of

700 m.

Sensor type

Retroreflective Models (with M.S.R)

Model NPN output

E3S-R11/-R16/-R61/-R66

Item

PNP output

E3S-R31/-R36/-R81/-R86

Sensing distance

1 m (100 mm) *1(When using the E39-R1)

*1. Values in parentheses indicate the minimum required distance between the sensor and reflector.

Standard sensing object

75-mm dia. or larger opaque LCD glass plate (thickness: 0.7 mm)

Directional angle

3 to 10°

Light source (wave length)

Red LED (700 nm)

Power supply voltage

10 to 30 V DC (including 10% ripple (p- p))

Current consumption

30 mA max.

Control output

Load supply voltage: 30 VDC or less, load current: 100 mA or less (residual voltage of 1 V or less), 
NPN open collector output, Light ON / Dark ON switching

Protective circuits

Reverse polarity protection, output short-circuit protection, mutual interference prevention

Response time

Operation or reset: 1 ms max.

Sensitivity adjustment

2-revolution endless volume

Ambient illuminance

Incandescent lamp: 5,000 lux max. Sunlight 10,000 lux max.

Ambient temperature

Operating: 0 to +40°C, storage: -40 to +70°C (no ice formation or condensation)

Ambient humidity

Operating: 35 to 85% RH, Storage: 35 to 95% RH (no condensation)

Insulation resistance

20 M   min. at 500 VDC

Dielectric strength

1,000 VAC at 50/60 Hz for 1 minute

Vibration resistance

10 to 55 Hz, 1.5 mm double amplitude for 2 hours each in X, Y, and Z directions

Shock resistance

Destruction: 500 m/s

2

 for 3 times each in X, Y, and Z directions

Protective structure

IEC 60529 IP67

Connection method

Pull-out cable type (standard cord length: 2 m) / connector type

Weight (Packed state)

Approximately 110 g (pull-out cable type) Approximately 60 g (connector type)

Material

Case

PBT (polybutylene terephthalate)

Lens

Denatured polyarylate

Mounting Brackets

Stainless steel (SUS304)

Accessories

Clamps (with screws), operation manual, reflector

6

5

4

3

2

1

0

0.4

0.8

1.2

1.6

2.0

Distance (mm)

Operating 
voltage

Reflector: E39-R1

Excess gain ratio

Sensing object
Shape

Model

E3S-R11, R61, R81; 

E3S-R16, R66, R36, R86

Passage position

Center

Glass 
plate

50 x 50 t = 0.5

82

50 x 50 t = 1

74

50 x 50 t = 2

73

50 x 50 t = 3

62

50 x 50 t = 5

53

50 x 50 t = 10

38

Liquid 
crystal 
glass

t = 0.5 (98% transparency) 

86

t = 0.7 (95% transparency) 

81

t = 1.1 (91% transparency) 

75

Operating range

95 max.

Stable operating range

90 max.

Отзывы: