A-91
E3NT
E3NT
Nomenclature
Operation
Setting the switching points
The switching points can either be user set (Teach-in mode)
with a measured object positioned at the corresponding dis-
tance or can be set using the setting input, for remote setting.
For each output of the sensor (up to two), up to two switching
points can be user set.
Only one switching point is active in the foreground and back-
ground suppression modes.
For the 2-point window evaluation mode, two switching points
must be set.
Teaching the switching points in the normal mode
The sensor is set at the factory for both outputs to
BGS
, light
on.
1. Place the target object in front of the sensor at the desired
position.
2. Teach the switching point for output 1:
• Beginning with the
key, press it simultaneously with the
ENTER
key. Threshold level is obtained and the output/
LED is updated. Status LED is blinking.
• Using the
/ keys an adjustment of the switching point is
possible. The output/LED is updated immediately.
• Pressing the ENTER
key for more than 2 seconds or af-
ter 2 minutes without any activation of the keys, the sensor
returns to normal operation. The status LED is turned off.
3. Teach the switching point for Output 2:
• Beginning with the key, press it simultaneously with the
ENTER
key.
Main menu structure
When the ENTER
key is pressed for 2 seconds, the sensor
switches from the normal mode to the TEACH menu path.
The sensor switches to each next menu path when the EN-
TER
key is repeatedly pressed for 2 seconds. In the menu
paths, the required parameters can be selected by pressing
and
keys.
To skip a menu path, you can also press the ENTER key
for 4 seconds.
[ENTER]
Press the ENTER
key < 1 second
[ENTER 2s]
Press the ENTER
key > 2 seconds.
LED display
The distance from the measured object and the names of the menu levels during set-up of the sensor are
displayed by the 4-digit 7-segment LED display.
The display appears as red digits or letters.
If the sensor is set to a bar chart display, the distance from the measured object is displayed as a green
LED bar chart.
LED
The switching status and the stability of the two outputs are signalled as follows by two LEDs, visible from
the top and the front of the sensor:
Yellow LED (Output 1)
ON
Object stably detected
Blinking
Object not stable detected
OFF
No object within range
Red LED (Output 2)
ON
Object stably detected
Blinking
Object not stable detected
OFF
No object within range
Status LED
ON
Set-up menu selected
Blinking
Menu level with change of setting distance
OFF
RUN (normal) mode
LED display
Status LED
optical IR element for data communication
Red LED
(Output 2)
Yellow LED
(Output 1)
Alignment aid
ENTER
Increment
Decrement
≈
≈
tch
Normal
operation
Enter 2 s
5Et
0Pt
팫
/
팬
팫
/
팬
팫
/
팬
Menu path
TEACH
Menu path
SET
Menu path
OPTIONS
Enter 2 s
Enter 2 s
Enter 2 s
Switching
point
settings
Additional
settings
Function
settings
Status LED
OFF
ON
≈
F502-EN2-04.book Seite 91 Dienstag, 26. Juli 2005 5:48 17