A-128
Standard Photoelectric Sensors
Zone teaching
Note: Perform zone teaching with the background.
Maximum distance setting (in normal mode)
If you want to set the maximum distance of the sensor, set a
maximum distance as depicted in the following procedure.
Precautions
Design
Power Supply
A full-wave rectification power supply can be used with the
E3G-MR19(T)-G.
Wiring Considerations
The tensile strength of the cable during operation should not
exceed the values shown below.
●
For adjustment
Display
• The following graphs indicate the status of each operation
level.
• Set the E3G so that it will work within the stable operation
range.
Design
Power Supply
A full-wave rectification power supply can be used with the
E3G-ML79(T)-G.
Wiring Considerations
The tensile strength of the cable during operation should not
exceed the values shown below.
Miscellaneous
EEPROM Write Error
If a write error occurs (operation indicator flickers) due to pow-
er-off, static electricity or other noise in the teaching mode,
perform teaching again.
Wiring Considerations
• The cable with an external diameter of 6 to 8 mm is recom-
mended.
• Securely tighten the cover to maintain water resistance and
dust resistance. The thread size of the conduit socket is PG
13.5
• Do not tighten with the cable caught by the terminal protec-
tion cover. Otherwise, the water-resistant structure and like
cannot be maintained.
Pro-
ce-
dure
Operation
1
Set the mode selector to
.
2
Set the NORMAL/ZONE mode selector to
.
3
Press the
button with the background.
The teaching indicator (red) will turn ON and the teaching
indicator (green) will then turn ON.
4
Set the mode selector to
. (Set to L-ON or D-ON
mode.)
TEACH
ZONE
TEACH
RUN
Pro-
ce-
dure
Operation
1
Set the mode selector to
.
2
Set the NORMAL/ZONE mode selector to
.
3
Press the
button 3 s or more.
The teaching indicator (red) will turn ON.
In 3 s, the teaching indicator (green) will turn ON.
4
When the teaching indicator (green) turns ON, the setting
is complete. Set the mode selector to
. (Set to L-ON/
D-ON.)
TEACH
NORMAL
TEACH
RUN
Correct Use
E3G-R/MR
Model
Tensile strength
E3G-R13-G
E3G-MR19(T)-G
50 N max.
E3G-R17-G
10 N max.
Stable
operation
range
(see note)
Stable
operation
range
(see note)
Unstable
operation
range
(see note)
Operation
level
Operation
level
x
0.8
Operation
level x 1.2
Stability indicator (green)
Incident level
Operation indicator (Orange)
L
·
ON
D
·
ON
OFF
OFF
OFF
ON
ON
ON
ON
Note: If the operation level is set to the stable operation range, the E3G will operate with
the highest reliability and without being influenced by temperature change, voltage
fluctuation, dust, or setting change.
E3G-L/ML
Model
Tensile strength
E3G-L73
E3G-ML79(T)-G
50 N max.
E3G-L77
10 N max.
E3G-M
#
(T)-G