Inductive Sensors

Ordering Information

Sensors

DC 2-wire Models

* Models with different response frequency are available (NO only). These model numbers take the form  E2S-

###

B (e.g., E2S-W11B)

DC 3-wire Models

* Models with different response frequency are available (NO only). These model numbers take the form  E2S-

###

B (e.g., E2S-W11B)

Accessories (Order Separately)

Mounting Brackets

Nomenclature

Shape

Sensing surface

Sensing distance

Model

Operating status

NO

NC

Front face

E2S-W11 *

E2S-W12

End face

E2S-Q11 *

E2S-Q12

Front face

E2S-W21 *

E2S-W22

End face

E2S-Q21 *

E2S-Q22

Shape

Sensing surface

Sensing distance

Output 

specifications

Model

Operating status

NO

NC

Front face

NPN

E2S-W13*

E2S-W14

End face

E2S-Q13*

E2S-Q14

Front face

E2S-W23*

E2S-W24

End face

E2S-Q23*

E2S-Q24

Front face

PNP

E2S-W15*

E2S-W16

End face

E2S-Q15*

E2S-Q16

Front face

E2S-W25*

E2S-W26

End face

E2S-Q25*

E2S-Q26

Shape

Model

Quantity

Remarks

Y92E-C1R6

1

Provided with E2S-

#

1

##

Y92E-C2R5

Provided with E2S-

#

2

##

Y92E-D1R6

---

Y92E-D2R5

---

Unshielded

1.6mm

2.5mm

Unshielded

1.6mm

2.5mm

1.6mm

2.5mm

E2S -

# # # #

A

 Compact square 

     series

B

 Sensing direction

     W: Front face sensing
     Q: End face sensing              

C

 Size and sensing distance

      (standard sensing object)
     1: 5.5 x 5.5 mm, 1.6 mm (iron)
     2: 8 x 8 mm, 2.5 mm (iron)   

D

 Output

     1: DC 2-wire NO
     2: DC 2-wire NC
     3: DC 3-wire NPN NO
     4: DC 3-wire NPN NC
     5: DC 3-wire PNP NO
     6: DC 3-wire PNP NC

E

 Different response 

     frequency
     No: Standard
     B: Different response 
     frequency

A

B C D E

F502-EN2-04.book  Seite 62  Dienstag, 26. Juli 2005  5:48 17

Содержание E2S

Страница 1: ...otection IEC60529 IP67 Significantly lower current consumption The 0 8 mA for 24 VDC leakage current for the DC 2 wire type has a ratio of ap proximately 1 20 compared to the conventional DC 3 wire type Optimum solution for multiple sensor applications such as cam switches 5 5 mm Adopted for more compact machines and devices 5 5mm 1 kHz IP67 1 20 Ultra small housing High Speed Response Environment...

Страница 2: ...ions Model Operating status NO NC Front face NPN E2S W13 E2S W14 End face E2S Q13 E2S Q14 Front face E2S W23 E2S W24 End face E2S Q23 E2S Q24 Front face PNP E2S W15 E2S W16 End face E2S Q15 E2S Q16 Front face E2S W25 E2S W26 End face E2S Q25 E2S Q26 Shape Model Quantity Remarks Y92E C1R6 1 Provided with E2S 1 Y92E C2R5 Provided with E2S 2 Y92E D1R6 Y92E D2R5 Unshielded 1 6mm 2 5mm Unshielded 1 6mm...

Страница 3: ...ching capacity 3 to 50 mA DC max Residual voltage 3 V max under load current of 50 mA with cable length of 1 m Indicator lamp 1 models Operation indicator red LED Operation set indicator green LED 2 models Operation indicator red LED Operating status with sensing object approaching 1 models NO 2 models NC Model E2S W13 E2S W14 E2S Q13 E2S Q14 E2S W23 E2S W24 E2S Q23 E2S Q24 E2S W15 E2S W16 E2S Q15...

Страница 4: ...tween energized parts and case Dielectric strength 1 000 VAC for 1 min between energized parts and case Vibration resistance 10 to 55 Hz 1 5 mm double amplitude for 2 hours each in X Y and Z directions Shock resistance Destruction 500 m s2 for 3 times each in X Y and Z directions Protective structure IEC60529 IP67 Connection method Pre wired models Standard length 3 m Weight Packed state Approx 10...

Страница 5: ...Sensor ON OFF ON OFF ON OFF Setting indicator green Operation indicator red Control output Load Brown Blue Main circuit V 0V 100 0 Sensing object Sensing zone Non sensing zone Non sensing zone Proximity Sensor ON OFF ON OFF Operation indicator red Control output Yes No ON OFF ON OFF Sensing object Operation indicator orange Output transistor load Load Brown Black Output Blue Main circuit V 0V Maxi...

Страница 6: ...adjacent Sensors to suppress mutual interference as provided in the following diagram Unit mm Note The above values in parentheses are applicable when using two sensors with different frequencies Mounting Tightening torgues Do not tighten the E2S W Q 2 mounting screws to a torque exceeding 0 7 Nm Correct Use Model Length A B C E2S W1 0 8 2 E2S W2 15 10 Model Length A B C E2S Q1 8 3 2 E2S Q2 15 10 ...

Страница 7: ...conductor sectional area 0 14mm2 Insulator diameter 0 9 dia standard length 1 m 7 4 7 8 2 3 11 3 20 3 10 8 2 5 2 2 3 1 dia If mounting bracket is attached E2S Q2 If mounting bracket is attached 8 8 4 8 2 3 8 9 14 5 3 6 4 1 18 5 11 3 23 3 Sensing surface Indicator 2 9 dia vinyl insulated round cable 2 3 cores conductor sectional area 0 14m u Insulator diameter 0 9 dia standard length 1 m 10 8 3 1 d...

Страница 8: ... of product improvement specifications are subject to change without notice ALL DIMENSIONS SHOWN ARE IN MILLIMETERS To convert millimeters into inches multiply by 0 03937 To convert grams into ounces multiply by 0 03527 Cat No E902 E2 02 X ...