111
Connectable Device Lists
Appendix A
Connectors
Model
Specifications
Remarks
XW4B-05C1-H1-D
Straight connector with attachment screws for node
or T-branch Tap connections
With connector attachment screws
MSTB2.5/5-ST-5.08AU
Straight connector without attachment screws for
node connections
Without connector attachment screws
PHOENIX CONTACT model number
1752399
XW4B-05C1-VIR-D
Right-angle connector with attachment screws for
node or T-branch Tap connections
With connector attachment screws
XW4G-05C1-H1-D
Straight clamp connector with attachment screws for
node or T-branch Tap connections
With connector attachment screws
XW4B-05C4-TF-D
Right-angle multi-drop connector with attachment
screws for node or T-branch Tap connections
With connector attachment screws
XW4B-05C4-T-D
Right-angle multi-drop connector without attachment
screws for node or T-branch Tap connections
Without connector attachment screws
XW4G-05C4-TF-D
Straight multi-drop clamp connector with attachment
screws for node or T-branch Tap connections
With connector attachment screws
DCN4-SF4D
Flat cable connector with attachment screws, for con-
necting nodes
With connector attachment screws
DCA1-5CN
@@
W1
Thin cable with shielded, micro-size (M12) connec-
tors on both ends for Environment-resistive Slave or
shielded T-branch Connector (micro-size) connec-
tions
Available cable lengths:
0.5 m, 1 m, 2 m, 3 m, 5 m, and 10 m
DCA1-5CN
@@
F1
Thin cable with shielded, micro-size (M12) female
connector on one end for Environment-resistive
Slave or shielded T-branch Connector (micro-size)
connections
Available cable lengths:
0.5 m, 1 m, 2 m, 3 m, 5 m, and 10 m
DCA1-5CN
@@
H1
Thin cable with shielded, micro-size (M12) male con-
nector on one end for shielded T-branch Connector
(micro-size) connections
Available cable lengths:
0.5 m, 1 m, 2 m, 3 m, 5 m, and 10 m
DCA2-5CN
@@
W5
Thin cable with shielded mini-size male connector on
one end and shielded micro-size (M12) female con-
nector on the other end for Environment-resistive
Slave or shielded T-branch Connector connections
Available cable lengths:
1 m, 2 m, 5 m, and 10 m
DCA2-5CN
@@
W1
Thick cable with shielded, mini-size connectors on
both ends for Environment-resistive Slave or
shielded T-branch Connector (mini-size) connections
Available cable lengths:
1 m, 2 m, 5 m, and 10 m
DCA2-5CN
@@
F1
Thick cable with shielded, mini-size female connector
on one end for Environment-resistive Slave or
shielded T-branch Connector (mini-size) connections
Available cable lengths:
1 m, 2 m, 5 m, and 10 m
DCA2-5CN
@@
H1
Thick cable with shielded, mini-size male connector
on one end for Environment-resistive Slave or
shielded T-branch Connector (mini-size) connections
Available cable lengths:
1 m, 2 m, 5 m, and 10 m
XS2G-D5S7
Shielded, micro-size (M12) female connector for cus-
tom cable assembly (for Environment-resistive Slave
or shielded T-branch Connector (micro-size) connec-
tions)
---
XS2C-D5S7
Shielded, micro-size (M12) male connector for cus-
tom cable assembly (for shielded T-branch Connec-
tor (micro-size) connections)
---
Содержание DEVICENET -
Страница 1: ...DeviceNet Cat No W267 E1 11 OPERATION MANUAL...
Страница 2: ...DeviceNet Operation Manual Revised April 2008...
Страница 3: ...iv...
Страница 5: ...vi...
Страница 7: ...viii...
Страница 9: ...x...
Страница 13: ...xiv...
Страница 41: ...20 Basic Operating Procedures Section 1 4...
Страница 107: ...86 Operational Checklist Section 2 6...
Страница 123: ...102 Step 3 Splitting the System into Multiple Power Supplies Section 3 6...