background image

8

Touch Switch

 

D5C

Grounding

In order to maintain the operational reliability of the D5C, be sure to
ground the blue or black wire of the power cord.

The service power supply of the PC (Programmable Controller) is not
available to the D5C-1D

@

0. The negative line of the service power

supply of the PC is not grounded. Therefore, the D5C may not oper-
ate.

Furthermore, if the negative line of the service power supply is
grounded, the noise resistance of the PC will drop.

Provided that single-phase 200 V is supplied to the D5C-1A

@

0, if

one phase is grounded, the power supply will be short-circuited and
a machinery breakdown will result. Use an isolating transformer and
ground the secondary side of the transformer instead.

In the above case, be sure to ground the secondary side, otherwise
the D5C may not operate.

Mounting

Do not tighten the nuts with excessive force. The maximum permissi-
ble tightening force of each nut with a washer is 29.4 N • m.

Others

Do not disassemble the D5C, otherwise the internal wiring will be
damaged and the D5C will fail to operate.

The sealing of the D5C uses nitrile butadien rubber (NBR), which is
highly oil resistive. If exposed to some types of oil or chemical
indoors or outdoors, however, the NBR may deteriorate. Contact your
OMRON representative for details.

When mounting the antenna to the D5C, be sure to tighten the
antenna to a torque of 0.39 to 0.83 N·m. If the antenna is not tight-
ened securely, the built-in contact may break.

If an appropriate antenna is mounted to a free attachment model,
hold the nut on the outer side with a wrench so that the nut will not
move. Then tighten the nut on the inner side within a torque range of
0.78 and 1.18 N·m.

In the interest of product improvement, specifications are subject to change without notice.

ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.

To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.

Cat. No. C061-E2-04

D5C

AC

Load

Brown

Blue

(Black)

The lead wire colors of the D5C have been changed in 
compliance with the latest applicable JIS standards. Col-
ors in parentheses are previous ones.

(White)

18.5

+0.5

0

dia.

Mounting Hole Dimension

Wrench

Direction of turn

Antenna

Содержание D5C

Страница 1: ...ending tip of antenna Overtravel of 20 mm max Ideal for high accuracy position con trol Overtravel of 3 5 mm max Any actuator can be attached Cable 3 m Actuator Power source DC D5C 1DS0 D5C 1DP0 D5C 1...

Страница 2: ...5 Switch category D IEC335 Vibration resistance 10 to 55 Hz 1 5 mm double amplitude Shock resistance 1 000 m s2 min Ambient temperature Operating 25 C to 70 C with no icing Ambient humidity 95 max Wei...

Страница 3: ...itivity Temperature Characteristics of DC Models Temperature Characteristics of AC Models Sensitivity pF Temperature C Sensitivity pF Temperature C 200 150 100 50 0 100 200 300 45 0 50 100 150 200 10...

Страница 4: ...nal lock washers Overtravel 4 dia 1 2 dia see note 1 See note 2 16 5 dia 6 5 dia 16 7 dia 7 1 dia 29 dia Caution label see note 3 DC Models Coil Spring Plunger Free attachment Note 1 The stainless ste...

Страница 5: ...ia Two clamping nuts Width 24 thickness 4 Caution label see note 3 AC Models Coil Spring Plunger Free attachment Note 1 The stainless steel wire actuator can move in any direction However limit the ov...

Страница 6: ...ith paint cannot be detected however because there is no electri cal continuity between the antenna and the conductor Non conductive objects e g plastic ceramic glass and cloth objects can be detected...

Страница 7: ...es or high tension lines or lay the cord in an exclusive shielded conduit Remove the caution label on the end of the cord before wiring the cord D5C 1A 0 AC Models Be aware that the D5C 1A 0 not in op...

Страница 8: ...nal wiring will be damaged and the D5C will fail to operate The sealing of the D5C uses nitrile butadien rubber NBR which is highly oil resistive If exposed to some types of oil or chemical indoors or...

Отзывы: