D5C

Series Classification and Features

Connections

Output Circuit Diagram

The lead wire colors of the D5C have been changed in compliance with the latest applicable JIS standards. Colors in parentheses are previous ones.

D5C-1D

@

0 (DC Model)

D5C-1A

@

0 (AC Model)

Dimensions

(Unit: mm)

DC Models

D5C-1D

@

0

Power supply 1
12 to 24 VDC

The D5C by itself can directly switch  
a load if DC power is provided.

200 mA max.
 L/R

0

D5C-1A

@

0

Power supply
100 to 240 VAC

An AC power supply can be detected  
and an AC load can be switched. 

200-mA load max.

 Cos

φ

 = 1

4.7 k

12 to 24 VDC

Brown (Red)

Black (White)

Blue (Black)

Switch
main
circuit

Load

100 to 240 VAC

Brown (White)

Blue (Black)

Switch
main
circuit

Load

*3
Caution label

*1. The stainless steel wire actuator can move in any direction. However, 
 

limit the overtravel to within 20 mm from the free position. The force that

 

pushes the actuator must not exceed 1.96 N.

*2  Vinyl insulated round cable (oil- and shock-resistant type)
 

4 dia., three conductors 

×

 0.2 mm

2

*3  Use after removing the caution label.

* 2

LED Operation indicator

M18 

×

 1

Two internal lock washers

Two clamping nuts

(

)

Width: 24
Thickness: 4

Overtravel

6.5 dia.

1.2 dia.  *1

16.5 dia.

16.7 dia.

29 dia.

7.1 dia.

4 dia.

14

51

101.5

4

37

(3,000)

56

61

(162.5)

4

Coil Spring
D5C-1DS0

* 2

*1

LED Operation indicator

M18 

×

 1

Two internal lock washers

Overtravel

5 dia.

16.5 dia.

16.7 dia.

29 dia.

7.1 dia.

4 dia.

24

4

37

(3,000)

56

61

(85)

4

Two clamping nuts

(

)

Width: 24
Thickness: 4

*3
Caution label

*1. The overtravel of the stainless steel plunger is within 3.5 mm.
 

Do not apply a force greater than 9.8 N to the plunger.

*2  Vinyl insulated round cable (oil- and shock-resistant type)
 

4 dia., three conductors 

×

 0.2 mm

2

*3  Use after removing the caution label.

Plunger
D5C-1DP0

Содержание D5C Series

Страница 1: ...ting Free attachment to enable changing the antenna shape according to the application Malfunction may occur if used in locations subject to water or oil Be sure to read Safety Precautions on page 6 t...

Страница 2: ...0 Hz Sensitivity setting range 30 to 100 pF Current consumption 17 mA max Leakage current Circuit 2 mA max Antenna 1 mA max 1 mA max Response time 2 ms max 8 ms max Output current 200 mA max resistive...

Страница 3: ...ity Temperature C Sensitivity pF 10 20 30 200 150 100 50 0 With sensitivity adjuster set to minimum sensitivity With sensitivity adjuster set to maximum sensitivity Voltage V Sensitivity pF 200 300 10...

Страница 4: ...ction However limit the overtravel to within 20 mm from the free position The force that pushes the actuator must not exceed 1 96 N 2 Vinyl insulated round cable oil and shock resistant type 4 dia thr...

Страница 5: ...6 N 2 Vinyl insulated round cable oil and shock resistant type 4 dia three conductors 0 3 mm2 3 Use after removing the caution label Coil Spring D5C 1AS0 2 1 LED Operation indicator M18 1 Two internal...

Страница 6: ...nded provided that the total length of the antenna is 1 m maximum Fig 2 and that the bottom of the antenna is at least 10 cm Fig 3 away from the ground Refer to the illustrations below The D5C may be...

Страница 7: ...er supply of the PC Programmable Controller is not available to the D5C 1D 0 The negative line of the service power supply of the PC is not grounded Therefore the D5C may not operate Furthermore if th...

Страница 8: ...products Outdoor use uses involving potential chemical contamination or electrical interference or conditions or uses not described in this catalog Nuclear energy control systems combustion systems r...

Отзывы: