D4MC
D4MC
4
Engineering Data (Reference Data)
Mechanical Life Expectancy (D4MC-5000)
Life expectancy (x 10 operations)
4
Overtravel (mm)
Operating temperature: 20
±
2
°
C
Operating humidity: 65
±
5%
No load
Operating frequency: 120 operations/min
Electrical Life Expectancy
Life expectancy (x 10 operations)
4
Operating temperature: 20
±
2
°
C
Operating humidity: 65
±
5%
Operating frequency: 20 operations/min
10,000
5,000
2,000
1,000
500
200
100
0.01 0.02
0.05 0.1
0.2
0.5
1
2
5
10
10,000
7,000
5,000
3,000
1,000
700
500
300
100
70
50
30
10
10
12
8
6
4
2
0
125 VAC cos
φ
=1
125 VAC cos
φ
=0.4
250 VAC cos
φ
=1
250 VAC cos
φ
=0.4
Operation
Contact Form
COM
NO
NC
Dimensions
Note:
1. All units are in millimeters unless otherwise indicated.
2. Unless otherwise specified, a tolerance of
±
0.4 mm applies to all dimensions.
Panel Mount Plunger
D4MC-5000
Note:
1.
Stainless steel plunger
2.
The length of the imperfect
threads is 1.5 mm maximum.
M12 x 1 mounting screw
Two hexagon nuts
(thickness: 3
width: 17)
Two, 4.3
±
0.1 dia.
mounting holes
Seal rubber (NBR)
Terminal
protective
cover
22 max.
(See
note 2)
(See note 1)
8.4 dia.
(21 x 21)
15
16
dia.
Panel Mount Roller Plunger
D4MC-5020
Note:
1.
Stainless steel roller
2.
The length of the imperfect
threads is 1.5 mm maximum.
12.7 dia.
×
5 (see note 1)
(See
note 2)
M12 x 1 mounting screw
Two hexagon nuts
(thickness: 3
width: 17)
Terminal
protective
cover
Two, 4.3
±
0.1 dia.
mounting holes
Seal rubber (NBR)
22 max.
(21 x 21)
15
16
dia.