D4MC
D4MC
2
Specifications
Ratings
Rated voltage
Non-inductive load
Inductive load
Resistive load
Lamp load
Inductive load
Motor load
NC
NO
NC
NO
NC
NO
NC
NO
125 VAC
10 A
3 A
1.5 A
10 A
5 A
2.5 A
250 VAC
10 A
2.5 A
1.25 A
10 A
3 A
1.5 A
480 VAC
3 A
1.5 A
0.75 A
2.5 A
1.5 A
0.75 A
8 VDC
10 A
3 A
1.5 A
6 A
5 A
2.5 A
14 VDC
10 A
3 A
1.5 A
6 A
5 A
2.5 A
30 VDC
6 A
3 A
1.5 A
5 A
5 A
2.5 A
125 VDC
0.5 A
0.4 A
0.05 A
0.05 A
250 VDC
0.25 A
0.2 A
0.03 A
0.03 A
Inrush current
NC
30 A max.
us cu e
NO
15 A max.
Note:
1. The above figures are for steady-state currents.
2. Inductive loads have a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC).
3. Lamp load has an inrush current of 10 times the steady-state current.
4. Motor load has an inrush current of 6 times the steady-state current.
5. The above ratings were tested under the following conditions according to JIS C4508.
Ambient temperature:
20
±
2
°
C
Ambient humidity:
65
±
5%
Operating frequency:
20 operations/min
Approved Standard Ratings
UL/CSA
A300
Rated voltage
Carry current
Current
Volt-amperes
a ed o age
Ca y cu e
Make
Break
Make
Break
120 VAC
10 A
60 A
6 A
7,200 VA
720 VA
240 VAC
0
30 A
3 A
, 00
0
Micro load:
0.1 A, 125 VAC
0.1 A, 30 VDC
EN60947-1 and EN60947-5-1
250 V, 10 A (AC-12)