background image

D4MC

D4MC

2

Specifications

 Ratings

Rated voltage

Non-inductive load

Inductive load

Resistive load

Lamp load

Inductive load

Motor load

NC

NO

NC

NO

NC

NO

NC

NO

125 VAC

10 A

3 A

1.5 A

10 A

5 A

2.5 A

250 VAC

10 A

2.5 A

1.25 A

10 A

3 A

1.5 A

480 VAC

3 A

1.5 A

0.75 A

2.5 A

1.5 A

0.75 A

8 VDC

10 A

3 A

1.5 A

6 A

5 A

2.5 A

14 VDC

10 A

3 A

1.5 A

6 A

5 A

2.5 A

30 VDC

6 A

3 A

1.5 A

5 A

5 A

2.5 A

125 VDC

0.5 A

0.4 A

0.05 A

0.05 A

250 VDC

0.25 A

0.2 A

0.03 A

0.03 A

Inrush current

NC

30 A max.

us cu e

NO

15 A max.

Note:

1. The above figures are for steady-state currents.

2. Inductive loads have a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC).

3. Lamp load has an inrush current of 10 times the steady-state current.

4. Motor load has an inrush current of 6 times the steady-state current.

5. The above ratings were tested under the following conditions according to JIS C4508.

Ambient temperature:

20

±

2

°

C

Ambient humidity:

65

±

5%

Operating frequency:

20 operations/min

 Approved Standard Ratings

UL/CSA

A300

Rated voltage

Carry current

Current

Volt-amperes

a ed o age

Ca y cu e

Make

Break

Make

Break

120 VAC

10 A

60 A

6 A

7,200 VA

720 VA

240 VAC

0

30 A

3 A

, 00

0

Micro load:

0.1 A, 125 VAC
0.1 A, 30 VDC

EN60947-1 and EN60947-5-1

250 V, 10 A (AC-12)

Содержание D4MC

Страница 1: ...r 5000 Panel mount plunger 5020 Panel mount roller plunger 5040 Panel mount crossroller plunger 1020 Short hinge lever 1000 Hinge lever 2000 Hinge roller lever 2020 Short hinge roller lever 3030 One w...

Страница 2: ...ove figures are for steady state currents 2 Inductive loads have a power factor of 0 4 min AC and a time constant of 7 ms max DC 3 Lamp load has an inrush current of 10 times the steady state current...

Страница 3: ...D IEC335 Rated operating current Ie 10 A Rated operating voltage Ue 250 VAC Vibration resistance Malfunction 10 to 55 Hz 1 5 mm double amplitude see note Shock resistance Destruction 1 000 m s2 min Ma...

Страница 4: ...n Contact Form COM NO NC Dimensions Note 1 All units are in millimeters unless otherwise indicated 2 Unless otherwise specified a tolerance of 0 4 mm applies to all dimensions Panel Mount Plunger D4MC...

Страница 5: ...3 0 1 dia mounting holes Seal rubber NBR 21 x 21 22 max 15 Hinge Lever D4MC 1000 Note Stainless steel lever t 1 see note Terminal protective cover Two 4 3 0 1 dia mounting holes Seal rubber NBR 21 x...

Страница 6: ...cify the required length of V C T cable in addition to the model number of the Switch Example Standard type D4MC 5040 Location of lead outlet Underside Length of lead 1 m V C T lead When placing your...

Страница 7: ...thus affect the sealing capability Rubber packing Rubber packing Mounting When mounting the Switch with screws on a side surface fasten the Switch with M4 screws and use washers spring washers etc to...

Отзывы: