G-202
Safety Sensors / Components
Controller
1-pole Controller
2-pole Controller
Application Examples
Wiring Example for 1 Sensor and 2 Contactors (with D40B-J1):
Auto-reset
The configuration in this example is for auto-reset and contactor monitoring.
22.5
99
75
82
POWER (Green)
OUTPUT (Green)
3
2
A1
1
4
A2
X1 21 13
X2 22 14
D40B-J1
Terminal Arrangement
45.5
73
120
A1 + X1 2 1 13 23 31
−
X2 3 4 14 24
A2
32
POWER (Green)
OUTPUT (Green)
D40B-J2
Terminal Arrangement
M
KM1
KM2
KM1 KM2
2
1 A1
13
3
4 A2 X1 X2
14
KM1
KM2
Guard door
Fuse
D40B-J1
Controller
Blue*
Yellow*
Green*
Red*
Operation Flowchart
Switch: NO contact
Switch: NC contact
D40B-J1 safety output
KM1, KM2: NC contact
KM1, KM2: NO contact
See
Manual
Start
on page 9.
Switch
Actuator
Note:
The circuit in this example is equivalent to a Category 3 circuit.
*This example applies to Standard or Elongated Sensors. The wire colors for the High-temperature Type Sensors are different. Refer to
Sensor and Controller
Connection Examples
on page 10.