103
Procedures
Section 3-2
(2) The Function Block Holding Area words are allocated in H512 to H1535.
These words cannot be specified in instruction operands in the user pro-
gram. These words can also not be specified in the internal variable’s AT
settings.
(3) Words H512 to H1535 are contained in the Holding Area, but the ad-
dresses set as non-retained will be cleared when the power is turned
OFF and ON again or when operation is started.
(4) To prevent overlapping of instance area addresses and addresses used
in the program, set H512 to H1535 (Function Block Holding Area words)
for the non-retained area and retained area. If there are not sufficient
words, use words in areas not used by the user program. If another area
is set, the addresses may overlap with addresses that are used in the
user program.
If the addresses in the function block instance areas overlap with any of
the addresses used in the user program, an error will occur when compil-
ing. This error will also occur when a program is downloaded, edited on-
line, or checked by the user.
If addresses are duplicated and an error occurs, either change the function
block instance areas or the addresses used in the user program.
FQM1 Flexible Motion Controllers
Note
Bit data can be accessed even if the DM Area is specified for the non-retained
area.
CP-series CPU Units
FB Instance
Area
Default value
Applicable memory
areas
Start address
End address
Size
Non Retain
(See note.)
5000
5999
1000
CIO, WR, DM
Retain
None
Timers
T206
T255
50
TIM
Counters
C206
C255
50
CNT
Work Area Addresses
used in the user
program overlap with
the instance areas.
FB Instance
Area
Default value
Applicable memory
areas
Start address
End address
Size
Non Retain
H512
H1407
896
CIO, WR, HR, DM (See
note.)
Retain
H1408
H1535
128
HR, DM (See note.)
Timers
T3072
T4095
1024
TIM
Counters
C3072
C4095
1024
CNT
Содержание CX-PROGRAMMER V8.1
Страница 3: ...iv...
Страница 5: ...vi...
Страница 7: ......
Страница 15: ...xvi...
Страница 19: ...xx...
Страница 25: ...xxvi Application Precautions 4...
Страница 26: ...Part 1 Function Blocks...
Страница 27: ......
Страница 153: ...128 Procedures Section 3 2...
Страница 154: ...Part 2 Structured Text ST...
Страница 155: ......
Страница 159: ...134 CX Programmer Specifications Section 4 2...
Страница 205: ...180 Procedures Section 6 1...
Страница 207: ...182 System defined external variables supported in function blocks Appendix A...
Страница 229: ...204 Revision History...
Страница 230: ......