131
Commands and Responses for Controller Link Units
Section 6-5
Response Block
Parameters
Model number, version (response): The Controller Link Unit’s model num-
ber and version are returned as shown below, each 20 characters in ASCII
code. If fewer than 20 bytes of data are used, 20 (Hex) (i.e., spaces) will be
returned for the remaining bytes. In the version numbers shown below, the
spaces are represented by boxes (
@
).
Model number
Optical Ring Controller Link Unit for CVM1/CV-series PLCs:
(H-PCF cable) CVM1-CLK12
@@@@@@@@@@
(GI cable)
CVM1-CLK52
@@@@@@@@@@
Optical Ring Controller Link Unit for CS-series PLCs:
(H-PCF cable) CS1W-CLK12
@@@@@@@@@@
(GI cable)
CS1W-CLK52
@@@@@@@@@@
Version
V*
@
V*
@
V*
@@@
The leftmost “V*” (*: version) represents the Communications Controller data
link level version number. The middle one represents the Communications
Controller network level version number. The rightmost one represents the
Controller Link Unit version number.
Connection Method (Response)
The connection method parameter for the Controller Link Unit (wired or optical
bus/ring) is configured as follows:
Node address (response): The Controller Link Unit’s node address is
returned between 01 and 3E Hex (1 to 62).
Unit Address (response): The Unit address set for the Controller Link Unit
(10 Hex + Unit number), is returned in hexadecimal. Even when there is a Unit
number setting error, the Unit address is returned.
Network Address: The Controller Link Unit’s network address, as set in the
routing table, is returned in hexadecimal. When the routing table has not been
set, the address becomes 00 Hex.
6-5-5
CONTROLLER STATUS READ
Reads the Controller Link Unit’s controller status.
Command Block
Response
code
Command
code
Model
20 bytes
20 bytes
Version
Node
address
05
01
Wired/
Optical
Unit
address
Network
address
Connection type:
0: Wired
1: Optical bus/ring
−
: Not used
Bit
Maximum number of nodes
00: 32 nodes
01: 62 nodes
Transmission path format
0: Token-bus mode
1: Token-ring mode
Command
code
01
06
Содержание CS1W-CLK12-V1
Страница 3: ...iv ...
Страница 5: ...vi ...
Страница 9: ...x TABLE OF CONTENTS ...
Страница 11: ...xii ...
Страница 59: ...42 Component Names and Functions Section 3 1 Dimensions Unit mm ...
Страница 62: ...45 Component Names and Functions Section 3 1 Dimensions Unit mm ...
Страница 91: ...74 CVM1 and CV series Optical Ring Controller Link Units Section 4 2 ...
Страница 108: ...91 Setting Data Links Section 5 2 Device Information Setting Data Link Tables ...
Страница 125: ...108 Checking Data Link Status Section 5 4 ...
Страница 181: ...164 Setting Routing Tables Section 7 4 ...
Страница 199: ...182 Memory Areas Related to Duplex Operation Section 8 6 ...
Страница 275: ...258 Handling Precautions Section 10 7 ...
Страница 298: ...281 CS series Optical Bus Controller Link Units Appendix C Dimensions Unit mm 101 35 130 ...
Страница 299: ...282 CS series Optical Bus Controller Link Units Appendix C ...
Страница 311: ...Authorized Distributor Cat No W370 E1 03 Note Specifications subject to change without notice Printed in Japan ...
Страница 312: ...CS1W CLK12 V1 CVM1 CLK12 CS1W CLK52 V1 CVM1 CLK52 Optical Ring Controller Link Units Cat No W370 E1 03 OPERATION MANUAL ...