3
Set the following parameters.
IliGain
: 0.0099999998 (Default)
IpfGain
: 1 (Default)
IpbGain
: 0
Magnitude
: 1,000 bits
Dwell Time
: 50 ms
4
Click the
Current Step
button.
•
The current step response is dis-
played.
3 Connection Procedures
3-27
Application Guide Laser Application (O052)
3-4
Setup of the Motors and Encoder
3
3-4-3
T
uning of the Current Loop