Appendix F
Troubleshooting
133
Maintenance Parts
The battery life is 5 years at 25
o
C. If the battery is used at higher temperatures, its life is shortened. When the
battery voltage drops, the BAT ERR LED indicator blinks, and the Battery Low Flag (bit 06 of word n+1 in 2 word
mode and n+3 in 4 word mode, where n = 100 + 10 x machine number) turns ON. Replace the battery within 1 week
after the indicator blinks.
To replace the battery, take the following steps:
1.
Turn OFF the power to the ASCII Unit. If power is not supplied to the Unit, apply power to the Unit
for at least one minute and then turn it OFF.
2.
Press the upper side of the battery storage cover, and slide it down to remove.
3.
Disconnect the battery and connector and replace them with new ones.
4.
Replace the battery storage cover.
Notes on Handling
Turning off the power to the PC before replacing the ASCII Unit.
When returning a defective unit to OMRON, inform us of the abnormal symptoms in as much detail as possible.