Chapter 4: System Installation
NOTE:
The Aux I/O connector is not used in an Omron Adept system.
Table 4-1. Electrical Connector Pinout
Description
Function
Type
Pin
#
Pinout
Cable
J1
High Power on
servo motor
D-sub-M
2 + 5
A1
24 VDC
No. 1 (red)
A2
GROUND
No. 2 (blue)
J2
RS232
D-sub 9,
female
2
RX
D-sub 9, female
3
TX
5
GROUND
J4
Aux I/O
D-sub 15
1
Trigger out
Not used
4
GROUND
5
GROUND
6
24 VDC out
7
24 VDC out
8
Pick in
9
Flash in
14
Error Drive 1
15
Error Drive 2
Installing Cables and Power
The AnyFeeder requires the following cable connections:
l
the servo motor cable (supplied)
l
the RS-232 serial communications cable (supplied)
The AnyFeeder is equipped with fuses to protect the internal components.
The motor power 24 VDC input is protected with a 10 Amp fuse, and the parallel I/O 24 VDC
lines are protected with a 3 Amp fuse. These fuses can be replaced in the field.
If you suspect a problem with one or both of these fuses, contact your local Omron Support.