Omron 61F-GP-N8 - Скачать руководство пользователя страница 2

61F-GP-N

@

2

Compact Plug-in Models (11-pin Type)

Specifications

Note: 1.

The length when using completely insulated, 600-V, 3-conductor (0.75 mm

2

) cabtire cables. Usable cable lengths will become shorter as

the cable diameter or number of conductors becomes larger. For details, refer to 

Safety Precautions for Floatless Level Controllers

.

2.

The insulation resistance and dielectric strength indicate values between power terminals and Electrode terminals, between power 

terminals and contact terminals, and between Electrode terminals and contact terminals. For details, refer to 

Safety Precautions for 

Floatless Level Controllers

.

3.

Possible to use with 15 k

Ω

 or less, however, this may cause reset failure.

4.

61F-GP-NH High-sensitivity Controller uses advanced operation.

When the power supply voltage is applied, if there are some liquids between the electrodes (ground and operation electrodes), the inter-

nal relay will not operate.

When the power supply voltage is applied, if there are no liquids between the electrodes (ground and operation electrodes), the internal

relay will operate. 

If the advanced operation does not satisfy applications, consider using 61F-N8HY controller which uses sequential operation.

Item

General-purpose 

Controller

61F-GP-N

High-

temperature 

Controller

61F-GP-NT

Long-distance 

Controllers

61F-GP-NL 2KM 

(for 2 km)

61F-GP-NL 4KM 

(for 4 km)

High-sensitivity 

Controller

61F-GP-NH 

(see note 4)

Low-sensitivity 

Controller

61F-GP-ND

Two-wire 

Controller

61F-GP-NR

Controlling materials 

and operating condi-

tions

For control of ordi-

nary purified water 

or sewage water

For control of ordi-

nary purified water 

or sewage where 

operating ambient 

temperature is 

high.

For control of ordi-

nary purified water 

in cases where the 

distance between 

sewage pumps 

and water tanks or 

between receiver 

tanks and supply 

tanks is long or 

where remote con-

trol is required.

For control of liq-

uids with high spe-

cific resistance 

such as distilled 

water

For control of liq-

uids with low spe-

cific resistance 

such as salt water, 

sewage water, 

acid chemicals, al-

kali chemicals

For control of ordi-

nary purified water 

or sewage water 

used in combina-

tion with Two-wire 

Electrode Holder 

(incorporating a 

resistor of 6.8 k

Ω

)

Supply voltage

24, 100, 110, 120, 200, 220, 230 or 240 VAC; 50/60 Hz

Operating voltage 

range

85% to 110% of rated voltage

Interelectrode voltage

8 VAC

Interelectrode current

Approx. 1 mA AC max.

Approx. 0.12 mA 

AC max.

Approx. 1 mA AC max.

Power consumption

Approx. 3.5 VA max.

Interelectrode operate 

resistance

0 to approx. 4 k

Ω

0 to approx. 4 k

Ω

0 to approx. 1.3 k

Ω 

(for 2 km)

0 to approx. 0.5 k

Ω 

(for 4 km)

Approx. 10 k

Ω

 to 

approx. 40 k

Ω 

(see note 3)

0 to approx. 

1.3 k

Ω

0 to 

approx. 2 k

Ω

Interelectrode release 

resistance

Approx. 15 k to 

∞ Ω

Approx. 15 k to 

∞ Ω

4 k to 

∞ Ω 

(for 2 

km)

2.5 k to 

∞ Ω 

(for 4 

km)

Approx. 100 k to 

∞ Ω

Approx. 4 k to 

∞ Ω

Approx. 15 k to 

∞ Ω

Response time

Operate:80 ms max.

Release:160 ms max.

Cable length 

(see note 1)

1 km max.

600 m max.

2 km max.

4 km max.

50 m max.

1 km max.

800 m max.

Control output

1 A, 250 VAC (Inductive load: cos

φ

 = 0.4)

3 A, 250 VAC (Resistive load)

Ambient temperature

Operating:–10 to 55

°

C (–10 to 70

°

C for high-temperature controller)

Ambient humidity

Operating:45% to 85% RH

Insulation resistance 

(see note 2)

100 M

Ω

 min. (at 500 VDC)

Dielectric strength 

(see note 2)

2000 VAC, 50/60 Hz for 1 min.

Life expectancy

Electrical:

100,000 operations min.

Mechanical: 5,000,000 operations min.

Weight

Approx. 155 g

Accessories

Hold-down clip PFC-N8

Approved standards

UL508, CSA C22.2 No.14, EN61010-1, EN61326-1 Industrial electromagnetic environment

Содержание 61F-GP-N8 -

Страница 1: ...High sensitivity D Low sensitivity R Two wire T High temperature Refer to Safety Precautions for Floatless Level Controllers Position of LED indicator 2 1 61F GP Type General purpose Long distance fo...

Страница 2: ...rature is high For control of ordi nary purified water in cases where the distance between sewage pumps and water tanks or between receiver tanks and supply tanks is long or where remote con trol is r...

Страница 3: ...1F GP N NT NL ND 61F GP NR 61F GP NH 3 9 1 4 10 11 U 24 V 8 V Control circuit S0 S1 E3 5 E1 Ta1 Tc1 Tb1 8 6 7 U Ta2 Tc2 Tb2 3 9 1 4 10 11 U 24 V 8 V Control circuit S0 S1 E3 5 E1 Ta1 Tc1 Tb1 8 6 7 U T...

Страница 4: ...mmercial Voltage 61F GP N PS 3S 3 9 E2 E3 E1 P 8 V 0 V U U U 24 V Control circuit See note 4 8 7 6 5 10 11 1 2 Start Stop Contac tor Power supply Motor protection relay Waste water tank Note Be sure t...

Страница 5: ...U U 61F GP N 5 6 7 8 4 8 V 0 V 24 V 10 3 9 1 2 11 Control circuit U See note Water tank Note The power supply phases terminals 3 to 9 can be matched to use the same ground for the common Electrode the...

Страница 6: ...Control circuit U2 B PL PL See note Upper limit Lower limit Alarm Water tank Motor protection relay Note The power supply phases terminals 3 to 9 can be matched to use the same ground for the common...

Страница 7: ...oir MCCB R S M T 61F GP NR See note 5 4 P R 8 V 0 V 24 V PS 3SR 10 3 9 1 2 11 Control circuit E3 Contac tor T Commercial Voltage Power supply Motor protection relay Waste water tank Note Be sure to gr...

Страница 8: ...20 or 240 VAC 61F GP N 220 or 240 VAC Note 1 The diagram shows the connections for the water supply When draining change the connection from terminal 1 to terminal 11 2 Be sure to ground terminal 4 Po...

Страница 9: ...r control of liq uids with high spe cific resistance such as distilled water For control of liq uids with low spe cific resistance such as salt water sewage water acid chemicals alkali chemicals For c...

Страница 10: ...ply Control circuit 24 V Power supply 8 V see note 61F GP N8 N8L N8D N8HY 61F GP N8H 61F GP N8R 24 V 8 V Power supply Control circuit 2 2 4 3 61F GP N8Y 24 V 8 V Control circuit Power supply Note 24 V...

Страница 11: ...N8 P 8 V 0 V U U U 24 V See note 3 4 5 6 PS 3S E2 E3 E1 Start Stop 2 1 8 7 Control circuit Contac tor Power supply Motor protection relay Waste water tank Commercial Voltage Note Be sure to ground the...

Страница 12: ...T 61F GP N8R See note 7 8 1 2 P R 8 V 0 V 24 V PS 3SR 3 5 6 4 Control circuit Stop Start E1 Contac tor Commercial Voltage Power supply Motor protection relay Waste water tank Note Be sure to ground t...

Страница 13: ...r to the following diagrams Line voltage R S S T or R T 380 or 415 VAC Phase voltage N R N S or N T 220 or 240 VAC 61F GP N8 220 or 240 VAC Note Be sure to ground terminal 1 Power source 380 to 415 VA...

Страница 14: ...t provided with the Level Controller t 0 3 4 5 83 4 6 Approx 80 6 2 8 5 9 32 5 9 0 D 216 8037 I21 2 7 66 9 6 I7 FREQ 50 60 Hz SECON DARY 8 V AC VOLTA E 38 70 84 49 4 61F GP N8 PF083A 91 61F GP N8 N8L...

Страница 15: ...ther in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted Suitability of Use Omron Companies shall not be responsible for conformity...

Отзывы: