background image

61F-GP-N

@

14

Dimensions

Note:

All units are in millimeters unless otherwise indicated.

Safety Precautions

Refer to 

Safety Precautions for All Level Controllers

49.4

3

8

70

8

4

61F-GP-

N

PF113A

101

61F-GP-N, -NT, -NL, -NH, -ND, -NR, -N -TDL, -N14, -N15, -NH3

When mounting a Display Unit to a PF113A 
Surface-mounting Socket, secure the PF113A with 
the groove facing toward the bottom and then 
connect the 61F-GP-N the PFC-N8 accessory.

PFC-N8

Note:

PFC-N8 Mounting Bracket (provided with 
the Level Controller)

t = 0.3

4.5 

8

Approx. 

8

6 2 8 5

& ( 

9$&

32 : (5

9$0

D[

&2168037

I

21

)/2 $7/

(66

/(9(

/

6 :

I

7 & +

FREQ

. : 50/60

Hz

SECON

DARY

: 8 VAC

VOLTA

*

E

3

8

70

8

4

49.4

61F-GP-

N8

PF0

8

3A

91

61F-GP-N8, -N8L, -N8H, -N8HY, -N8D, -N8R

Use a PFC-N8 Mounting Bracket to mount the 
Level Controller to a PF083A Rail-mounted 
Socket.

PFC-N8

Note:

PFC-N8 Mounting Bracket (provided with 
the Level Controller)

8

3

4

4.5

t=0.3

6

Approx.

8

0

In the interest of product improvement, specifications are subject to change without notice.

ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.

To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.

Содержание 61F-GP-N8 -

Страница 1: ...High sensitivity D Low sensitivity R Two wire T High temperature Refer to Safety Precautions for Floatless Level Controllers Position of LED indicator 2 1 61F GP Type General purpose Long distance fo...

Страница 2: ...rature is high For control of ordi nary purified water in cases where the distance between sewage pumps and water tanks or between receiver tanks and supply tanks is long or where remote con trol is r...

Страница 3: ...1F GP N NT NL ND 61F GP NR 61F GP NH 3 9 1 4 10 11 U 24 V 8 V Control circuit S0 S1 E3 5 E1 Ta1 Tc1 Tb1 8 6 7 U Ta2 Tc2 Tb2 3 9 1 4 10 11 U 24 V 8 V Control circuit S0 S1 E3 5 E1 Ta1 Tc1 Tb1 8 6 7 U T...

Страница 4: ...mmercial Voltage 61F GP N PS 3S 3 9 E2 E3 E1 P 8 V 0 V U U U 24 V Control circuit See note 4 8 7 6 5 10 11 1 2 Start Stop Contac tor Power supply Motor protection relay Waste water tank Note Be sure t...

Страница 5: ...U U 61F GP N 5 6 7 8 4 8 V 0 V 24 V 10 3 9 1 2 11 Control circuit U See note Water tank Note The power supply phases terminals 3 to 9 can be matched to use the same ground for the common Electrode the...

Страница 6: ...Control circuit U2 B PL PL See note Upper limit Lower limit Alarm Water tank Motor protection relay Note The power supply phases terminals 3 to 9 can be matched to use the same ground for the common...

Страница 7: ...oir MCCB R S M T 61F GP NR See note 5 4 P R 8 V 0 V 24 V PS 3SR 10 3 9 1 2 11 Control circuit E3 Contac tor T Commercial Voltage Power supply Motor protection relay Waste water tank Note Be sure to gr...

Страница 8: ...20 or 240 VAC 61F GP N 220 or 240 VAC Note 1 The diagram shows the connections for the water supply When draining change the connection from terminal 1 to terminal 11 2 Be sure to ground terminal 4 Po...

Страница 9: ...r control of liq uids with high spe cific resistance such as distilled water For control of liq uids with low spe cific resistance such as salt water sewage water acid chemicals alkali chemicals For c...

Страница 10: ...ply Control circuit 24 V Power supply 8 V see note 61F GP N8 N8L N8D N8HY 61F GP N8H 61F GP N8R 24 V 8 V Power supply Control circuit 2 2 4 3 61F GP N8Y 24 V 8 V Control circuit Power supply Note 24 V...

Страница 11: ...N8 P 8 V 0 V U U U 24 V See note 3 4 5 6 PS 3S E2 E3 E1 Start Stop 2 1 8 7 Control circuit Contac tor Power supply Motor protection relay Waste water tank Commercial Voltage Note Be sure to ground the...

Страница 12: ...T 61F GP N8R See note 7 8 1 2 P R 8 V 0 V 24 V PS 3SR 3 5 6 4 Control circuit Stop Start E1 Contac tor Commercial Voltage Power supply Motor protection relay Waste water tank Note Be sure to ground t...

Страница 13: ...r to the following diagrams Line voltage R S S T or R T 380 or 415 VAC Phase voltage N R N S or N T 220 or 240 VAC 61F GP N8 220 or 240 VAC Note Be sure to ground terminal 1 Power source 380 to 415 VA...

Страница 14: ...t provided with the Level Controller t 0 3 4 5 83 4 6 Approx 80 6 2 8 5 9 32 5 9 0 D 216 8037 I21 2 7 66 9 6 I7 FREQ 50 60 Hz SECON DARY 8 V AC VOLTA E 38 70 84 49 4 61F GP N8 PF083A 91 61F GP N8 N8L...

Страница 15: ...ther in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted Suitability of Use Omron Companies shall not be responsible for conformity...

Отзывы: