Input Settings
16 and 12-bit Switch Settings
Set 16 or 12 bits to match the bit count of the input digital signal. Slide
the switch to the left for 16 bits and to the right for 12 bits.
[16/12-bit switch]
Parameter Settings
Set “3” (option) for the reference source (b1-01) setting.
Set the Digital Reference Card input (DI) selection (F3-01) for the in-
put signal specifications.
Setting
Description
0
BCD 1% units
1
BCD 0.1% units
2
BCD 0.01% units
3
BCD 1 Hz units
4
BCD 0.1 Hz units
5
BCD 0.01 Hz units
6
Special BCD settings (5-digit input from 0.00 to 399.99 Hz)
(See notes 1 and 2.)
7
Binary input (binary values displayed in decimal)
Note
1. The second digit below the decimal point is set by bits
8x10
0
, 4x10
0
, and 2x10
0
, so the settings are made in
units of 0.02 Hz. (If these three bits are “111,” “110,”
and “101,” they will be recognized as “9.”)
2. Only positive data can be set in order to use the Sign
(CODE) bit as a data bit.
Digital READ Timing
Use the following data settings and SET (READ) signal ON timing to
provide frequency references to the Inverter.
Frequency reference
data (D0 to 15, SIGN)
SET (READ) signal
5 ms min.
10 ms min.