2JCIE-BL01-P1 Environment Sensor (PCB Type) User’s Manual (A280)
23
2.2.9
Heat stroke
(Characteristics UUID: 0x301A)
Heatstroke risk factor related event settings
.
Table 24. Heat stroke format
Byte
Field
Format
Contents
0
Event Enable/Disable
UInt8
Bit 7-6 : RFU
Bit 5 : Simple threshold [lower limit]
Bit 4 : Simple threshold [upper limit]
Bit 3 : Changing trend [decline/term]
Bit 2 : Changing trend [rise/term]
Bit 1 : Changing trend [decline/previous]
Bit 0 : Changing trend [rise/previous]
Enable: 1, Disable: 0
Default
:
0x00
1
Changing trend threshold
[rise/previous]
L
SInt16
Unit
:
0.01 degC
Range
:
0.01
~
30.00 degC
Default
:
0x012C (3.00 degC)
2
H
3
Changing trend threshold
[decline/previous]
L
SInt16
4
H
5
Changing trend threshold
[rise/term]
L
SInt16
6
H
7
Changing trend threshold
[decline/term]
L
SInt16
8
H
9
Simple threshold
[upper limit]
L
SInt16
Unit
:
0.01 degC
Range
:
25
~
40 degC
Default
:
0x0AF0 (28.00 degC)
10
H
11
Simple threshold
[lower limit]
L
SInt16
Unit
:
0.01 degC
Range
:
25
~
40 degC
Default
:
0x09C4 (25.00 degC)
12
H
13
Term for changing trend
(Number of Measurements)
UInt8
Unit
:
1 count
Range
:
1
~
8 count
Default
:
0x06 (6 count)
14
Moving average number
UInt8
Unit
:
1 count
Range
:
1
~
8 count
Default
:
0x01 (1 count)