Judging Measurement Values (Alarm Outputs)
42
ZG2-DSU User’s Manual
Judging Measurement Values (Alarm Outputs)
Specifying Tasks
When outputting the judgment results of measurements as alarms, specify the channel
and task to be used for judgment.
X
FUN mode-[I/O SET]-[SOURCE]
Setting Judgment Conditions
Set the two values, HIGH and LOW thresholds, used for alarm output. Three judgment
results are output, [HIGH], [PASS] and [LOW]. Set the judgment conditions in the TEACH
mode.
Setting value
Description
CH
Selects the channel of the Sensor Controller targeted for alarm
judgment. (1, 2, default value: 1) CH2 is not displayed when it is not
connected.
TASK
Selects the task targeted for alarm judgment. (1-8)
HIGH
ON
OFF
ON
OFF
ON
OFF
LOW
PASS
HIGH threshold
Measurement
value
LOW threshold
Output
(ON when
measurement value >
HIGH threshold)
(ON when LOW
threshold
≤
measurement value
≤
HIGH threshold)
(ON when
measurement value <
LOW threshold)
Содержание 257553
Страница 1: ...User s Manual Cat No Z289 E1 02 Smart Sensor Data Storage Unit ZG2 DSU...
Страница 10: ...8 ZG2 DSU User s Manual MEMO...
Страница 14: ...12 ZG2 DSU User s Manual MEMO...
Страница 38: ...Loading Logging Data to an External Device 36 ZG2 DSU User s Manual MEMO...
Страница 42: ...Transferring Bank Data to the Controller 40 ZG2 DSU User s Manual MEMO...
Страница 52: ...Bank Functions 50 ZG2 DSU User s Manual MEMO...
Страница 86: ...Updating the Firmware 84 ZG2 DSU User s Manual MEMO...
Страница 89: ...6 APPENDICES INDEX 87 ZG2 DSU User s Manual MEMO...
Страница 91: ......