No.12S162-03
30/47
STC-SC202POEHS / SB202POEHS
Users guide
Command No.
Command Description
16H:
SOFTRG[7..0]
[Software Trigger Setting] Initial data: SOFTRG[7..0] = 80H
Sets the source of the software trigger.
D[7..0]
D7
D6
D5
D4
D3
D2
D1
D0
D7 to D6:
Software trigger source selection
00: Programming software trigger
10: Command software trigger
(200 useconds pulse width trigger signal)
01, 11: No function
(Prohibited settings. Do not set these values)
D5 to D1:
No Function
Always set as “00000”
D0:
Generate software trigger command
0: Hold (Low State)
1: Generate command software trigger
(200 useconds high state)
Note 1: The software trigger source selection is enabled whenever “Trigger signal type (MOD3-D5)” is the software
trigger (set as 0)
Note 2: The “Programming software trigger” is used to set up the pulse duration, trigger signal interval and generate
the trigger signal.
Note 3: When selecting “Command software trigger”, it is necessary to generate the software trigger signal with the
“Generate command software trigger (SOFTRIG-D0)”.
17H:
IMAGEREST
[7..0]
[Image Data Reset] Initial data: IMAGEREST[7..0] = 00H
Reset the Image data (FVAL, LVAL and the image data).
Change from the reset to the image data out after starting the image acquisition.
The image data is not output when resetting the image data.
D[7..0]
D7
D6
D5
D4
D3
D2
D1
D0
D7 to D1:
No Function
Always set as “0000000”
D0:
Image Data Reset
0: FVAL/LVAL/Image data reset
(FVAL, LVAL and the image data are low state data)
1: FVAL/LVAL/Image data out
19H
FORMAT[7..0]
[Image output format] initial data: Monochrome FORMAT[7..0] = 00H, Color = 05H
Sets the output format of the image data.
D[7..0]
D7
D6
D5
D4
D3
D2
D1
D0
D7 to D4:
No Function
Always set as “0000”
D2 to D0:
Output format
000: Mono8
0101: BayerGR8
001: Mono10
0110: BayerGR10
010: Mono10Packed
0111: BayerGR12
011: Mono12
1000: BayerGR10Packed
100: Mono12Packed
1001: BayerGR12Packed
1010: RGB8Packed
1011 to 1111: No function (Prohibited setting. Do not set these values)
20H:
EXPTM[7..0]
21H:
EXPTM[15..8]
22H:
EXPTM[23..16]
[Exposure time (useconds) of the electronic shutter]
Initial data: EXPTM[23..0] = 0, data range: 0,10 to 16,777,215
Sets the exposure time for the electronic shutter.
Exposure time = EXPTM[23..0] useconds
When set as 0, the electronic shutter is OFF.