3.2.2
Exposure Timing with the Positive Polarity Trigger Signal
Note 1: The trigger signal will be removed by the filtering if the pulse width of the input trigger signal is less than 60 CLK.
Please input a trigger signal with more than 61 CLK pulse width.
Note 2: The exposure will start 172 CLK after the rising edge of the trigger signal.
3.2.3
Exposure Timing with the Negative Polarity Trigger Signal
Note 1: The trigger signal will be removed by the filtering if the pulse width of the input trigger signal is less than 60 CLK.
Please input a trigger signal with more than 61 CLK pulse width.
Note 2: The exposure will start 172 CLK after the rising edge of the trigger signal.
T1'
SUB
SG
(127
CLK)
Input Trigger signal
Exposure time
Exposure time: T1' = T1 + 127 CLK
T1
60 CLK
Filtering *Note.1
Trigger signal
(With Photocoupler delay
Less than
60 useconds
T1
112 CLK
T1'
SUB
SG
(127
CLK)
Input Trigger signal
Exposure time
Exposure time:: T1' = T1 + 127 CLK
T1
Filtering *Note.1
Trigger signal
(With Photocoupler delay
Less than
15 useconds
T1
60 CLK