To lounch OMOIKIRI Pure drop 2.1.4S at first time you must connect the delivery pipes and flush the modules.
How to connect JG pipe
Pull locking clip out of the plastic plug, pull one
extremity of the pipe, wet with water, in to the
connector plug until hard stop at deep 15 mm and
install locking clip back. Check the pipe fastening is
right. When it is pressure 8-10 KGS pipe does not
pull-out.
V-Complex 1 flushing
Open inlet valve. Turn on the clear water tap and wait until the water start to flow. The system will produce air with
noise. Run the water through the system for 10 minutes.
Turn off the clear water tap and let the purifier stand for 10 minutes. Run again the water through the purifier for 50
minutes. Turn off the inlet valve.
How to disconnect JG pipe
Pull locking clip out of the plastic plug and after pulling
one side of plastic plug disconnect the pipe. To pull one
side of plastic plug use pipe key.
1. CONNECT JG PIPES
V-Complex 1 installation
Turn through 90° contraclockwise three fixing plugs to take off the covering top.
Extract service plug, which is located under the covering top of the purifier.
Delete the packaging film from module V-Complex 1 and shipping plugs (if any given). Rinse the module sealing rings
under water.
For convenience the locking push buttons of the collectors are varied in color (black and red).
Install OMOIKIRI filtering module V-Complex 1 and service plug in the following order: black locking button —
V-Complex 1; red locking button — service plug.