Serial Interface Manual
OEL8000III Series Models K/X
Command: 102 System Configuration Report
Command Format:
Display: <SOH>I10200
Computer: <SOH>i10200
Typical Response Message, Display Format:
<SOH>
I10200
JUL 28, 2013 11:16 PM
OMNTEC MFG.
1993 POND ROAD
RONKONKOMA NEW YORK 11779
631-981-2001
SYSTEM CONFIGURATION
SLOT BOARD TYPE POWER ON RESET CURRENT
01 XB-416 (13.0) 198568C1 198862BE
02 XB-416 (11.1) 198568C1 198862BE
03 XB-416 (17.2) 198568C1 198862BE
04 UNUSED
05 XB-RB8 (5.0) 198568C1 198862BE
06 XB-RB8 (6.1) 198568C1 198862BE
07 UNUSED
08 UNUSED
MCUD (1.0) 198568C1 198862BE
DISPLAY (1.0) 198568C1 198862BE
<ETX>
Typical Response Message, Computer Format:
<SOH>i10200YYMMDDHHmmNNSSTTFFFFFFFFCCCCCCCC...
SSTTFFFFFFFFCCCCCCCC&&CCCC<ETX>
Notes:
1. YYMMDDHHmm - Current Date and Time
2. NN - Number of Modules to Follow (Hex)
3. SS - Slot Number (Hex)
4. TT - Type of Module (Hex):
30 - MCU
31 - DISPLAY
32 - 7100 - 8
33 - 7100 - 4
34 - RELAY-8R
35 - RELAY-4R4I
5. FFFFFFFF - Power On Reset, Always ‘0’ (ASCII Hex IEEE float)
6. CCCCCCCC - Current I/O Reading, Always ‘0’ (ASCII Hex IEEE float)
7. && - Data Termination Flag
8. CCCC - Message Checksum