18
9. If the fiberoptic connectors are to be installed after the fiber is pulled into the conduit, it is im-
perative that sufficient excess (<10 ft) be left on each end so that the connectors can be at-
tached conveniently.
10. The procedures for installation of the fiberoptic connectors on the fiberoptic cable is specific to
the cable type and the connector type, and must be performed by a trained technician.
These instructions assume the fiberoptic cable has already been performed.
11. Due to possible wide temperature changes, a stabilizer is required over the connectors and
mating sleeve located in the probe conduit j-box. The following steps will perform this re-
quirement..
a) Spread open the slit and place the stopper over the fiberoptic interconnect cable and the
FuelCheck
®
probe cable as shown. Attach the ST mating sleeve to the ST connector on
the interconnect cable.
b) Attach stabilizer tube to stopper as shown leaving the connector protruding from the end.
c) Apply a small dab of optical gel to the tips of the Probe ST connector by dipping it into the
optical gel container. Be careful not to allow any dirt to get into the gel.
Figure 24
Insert fiber in stopper
Figure 25
Attach Stabilizer Tube
Figure 26
Apply optical gel
FU-FO-CN
(fiberoptic connector)
FU-FO-MS
(fiberoptic mating sleeve)
Содержание FuelCheck
Страница 1: ...F FU UE EL LC CH HE EC CK K...
Страница 23: ...22 11 2 19 4 42 7 29 4 10 0 0 Figure 31 FuelCheck Control front view Figure 32 FuelCheck Controller inside view...
Страница 24: ...23 19 5 11 5 6 0 2 25 2 5 Figure 33 FuelCheck Controller mounting dimensions...
Страница 34: ...33...
Страница 35: ...34 APPENDICES...
Страница 36: ...35 APPENDIX A Warranty and Disclaimer...