19
Replacing the Fuse
If the fine-wire fuse of the device fuses, only replace the fuse by a fuse of same type and rating.
Before replacing the fuse, unplug mains lead.
Procedure:
Step 1:
Open the fuseholder on the rear panel with a fitting screwdriver.
Step 2:
Remove the old fuse from the fuseholder.
Step 3:
Install the new fuse in the fuseholder.
Step 4:
Replace the fuseholder in the housing.
..............................................................................................................................................................................
9
TECHNICAL SPECIFICATIONS
KM
KM
KM
KM-
--
-110A
110A
110A
110A
KM
KM
KM
KM-
--
-112A
112A
112A
112A
KM
KM
KM
KM-
--
-115A
115A
115A
115A
Power supply:
115/230 V AC, 50/60 Hz
115/230 V AC, 50/60 Hz
115/230 V AC, 50/60 Hz
Power consumption:
80 W (1/8 power)
180 W (1/8 power)
300 W (1/8 power)
Rated power:
150 W RMS
250 W RMS
250 W RMS
Program power:
300 W
500 W
500 W
Bass speaker:
25 cm (10")
30 cm (12")
38 cm (15")
Driver:
3.5 cm (1.35")
3.5 cm (1.35")
3.5 cm (1.35")
Input:
combination
XLR/6.3 mm jack
combination
XLR/6.3 mm jack
combination
XLR/6.3 mm jack
Parallel output:
XLR
XLR
XLR
Input impedance:
30 kΩ (balanced),
15 kΩ (unbalanced)
30 kΩ (balanced),
15 kΩ (unbalanced)
30 kΩ (balanced),
15 kΩ (unbalanced)
Frequency range:
60-20000 Hz
50-20000 Hz
45-20000 Hz
Max. SPL:
121 dB (1 m)
123 dB (1 m)
124 dB (1 m)
Dispersion angle (HxV): 80° x 80°
80° x 80°
60° x 60°
Circuitry:
class D/AB
class D/AB
class D/AB
Protection circuits:
overload, limiter
overload, limiter
overload, limiter
LED indicators:
power, signal, limit
power, signal, limit
power, signal, limit
Cabinet material:
15 mm MDF
15 mm MDF
15 mm MDF
Flange:
35 mm
35 mm
35 mm
Dimensions (LxWxH):
420 x 480 x 300 mm
460 x 500 x 340 mm
510 x 600 x 370 mm
Weight:
14 kg
17 kg
20 kg