15
4
OPERATING ELEMENTS & CONNECTIONS
Front Panel
No.
Element
Function
1
POWER switch
Turns power to the unit on and off. When powered on, the indicator
lights up.
2
Sliding controls
For boosting and attenuating the respective frequency band level
by ±6 dB or ±12 dB. To boost a frequency range, pull the sliding
control upward; to attenuate, pull the sliding control downward.
When in center position, the particular frequency range is not
processed at all.
3
RANGE selector switch
Switches over the control range of the equalizer controls from
±6 dB to ±12 dB. The LEDs below indicate the control range
selected.
4
BYPASS button
Disables and enables the equalizer section in order to compare the
processed signal with the original unprocessed signal (button
depressed). The LED below lights when the equalizer section is
disabled. Note: The LEVEL control remains unaffected by the
BYPASS button.
5
CLIP indicator
This LED lights up when the signal level reaches 5 dB below
clipping which may occur in the following cases: 1) the input level
exceeds +24 dBu, 2) excessive gain is applied by the LEVEL
control or 3) excessive boost is applied using the sliding controls.
6
LEVEL control
Adjusts the input signal level to the equalizer.
1
2
3
4
5
6
2
3
4
5
6