CONTROL_1_5_V_3_0.DOC
23/25
The installation must always be secured with a secondary safety attachment, e.g. an appropriate catch net.
This secondary safety attachment must be constructed in a way that no part of the installation can fall down
if the main attachment fails.
When rigging, derigging or servicing the speaker-system staying in the area below the installation place, on
bridges, under high working places and other endangered areas is forbidden.
The operator has to make sure that safety-relating and machine-technical installations are approved by an
expert before taking into operation for the first time and after changes before taking into operation another
time.
The operator has to make sure that safety-relating and machine-technical installations are approved by an
expert after every four year in the course of an acceptance test.
The operator has to make sure that safety-relating and machine-technical installations are approved by a
skilled person once a year.
Procedure:
The speaker-system should be installed outside areas where persons may walk by or be seated.
IMPORTANT! OVERHEAD RIGGING REQUIRES EXTENSIVE EXPERIENCE, including (but not limited to)
calculating working load limits, installation material being used, and periodic safety inspection of all
installation material and the speaker-system. If you lack these qualifications, do not attempt the installation
yourself, but instead use a professional structural rigger. Improper installation can result in bodily injury and
or damage to property.
Caution:
Speaker-systems in hanging installations may cause severe injuries when crashing down! If you
have doubts concerning the safety of a possible installation, do NOT install the speaker-system!
Installation on a wall-mounting
The speaker-system can be installed on a wall-mounting.
Suitable wall-mountings:
Wall-mounting for Control 1, 1 pair
No. 11229640
Wall-mounting f. Control 5
No. 11229645, 11229646
Wall-mounting XY f. Control 5
No. 11229648, 11229649
When installed on a wall-mounting, the speaker-system must always be secured with a safety-rope.
Before attaching the device, make sure that the installation area can hold a minimum point load of 10 times
the device's weight.
The device must only be installed absolutely planar at a vibration-free, oscilation-free and fire-resistant
location. Make sure that the device is installed absolutely planar by using a water-level.
The device must be installed out of the reach of people.
In order to safeguard sufficient ventilation, leave 50 cm of free space around the device.
The device must always be installed via all fixation holes. Do only use appropriate screws and make sure
that the screws are properly connected with the ground.
The durability of the installation depends very much on the material used at the installation area (building
material) such as wood, concrete, gas concrete, brick etc. This is why the fixing material must be chosen to
suit the wall material. Always ask a specialist for the correct plug/screw combination indicating the maximum
load and the building material.
Procedure:
Step 1:
On the wall-mounting, there are 2 holes for the installation.
Step 2:
Hold the wall-mounting onto the location where it is to be installed.
Step 3:
Mark the boreholes with a pen or a suitable tool.