Rack Mounting

The module can be rack mounted using the optional Rack Mount Shelf (8260-0).  

Refer to the Rack Mount Shelf user manual (040-08260-001x) for the proper 

installation guidelines.
Follow the same guidelines above when rack mounting the module.

3) Apply Power

AC Power

Secure the ground wire to the ground screw.  See the figure below for the location 

of the grounding screws.
Route the power cord through the provided strain relief for additional support and  

connect the barrel connector at the end of the wire on the AC/DC adapter to the 

barrel connector on the module.  Connect the AC/DC adapter to the AC outlet.  

Confirm that the module has powered up properly by checking the Power LED 

located on the front of the switch.

AC Models Rear View: Barrel Connector for AC/DC Power Adapter

NEVER ATTEMPT TO OPEN THE CHASSIS OR

SERVICE THE POWER SUPPLY. OPENING THE

CHASSIS MAY CAUSE SERIOUS INJURY OR DEATH.

THERE ARE NO USER REPLACEABLE OR

SERVICEABLE PARTS IN THIS UNIT.

WARNING!!!

DC Power

This module is intended for installation in restricted access areas. (“Les matériels 

sont destinés à être installés dans des EMPLACEMENTS À ACCÈS RESTREINT”). 

A restricted access area can be accessed only through the use of a special key, or 

other means of security.
The over current protection for connection with centralized DC shall be provided in 

the building installation, and shall be a UL listed circuit breaker rated 20 Amps, and 

installed per the National Electrical Code, ANSI/NFPA-70.
Appropriate overloading protection should be provided on the DC power source 

outlets utilized.

Page 10

The 6 Port 10G/Sx re12 to +57VDC inclusive of tolerances( 0.86A @ 

12VDC max rated power).  The 10 Port 10G/Sx re12 to +57VDC inclusive of 

tolerances (0.94A @ 12VDC max rated power).  See specification table for specific 

model requirements. 
Appropriate overloading protection should be provided on the DC power source 

outlets utilized.

DC Models Rear View: 2-Pin Terminal for DC Power

WARNING:

Only a DC power source that complies with

safety extra low voltage (SELV) requirements can be
connected to the DC-input power supply.

WARNING REGARDING EARTHING GROUND:

o

o

o

o

This equipment shall be connected to the DC supply

system earthing electrode conductor or to a bonding
jumper from an earthing terminal bar or bus to which the
DC supply system earthing electrode is connected.

This equipment shall be located in the same immediate

area (such as adjacent cabinets) as any other equipment
that has a connection between the earthed conductor of
the same DC supply circuit and the earthing conductor,
and also the point of earthing of the DC system. The DC
system shall not be earthed elsewhere.

The DC supply source is to be located within the same

premises as this equipment.

There shall be no switching or disconnecting devices in

the earthed circuit conductor between the DC source and
the earthing electrode conductor.

Locate the DC circuit breaker of the external power source, and switch the circuit 

breaker to the OFF position.
Prepare a power cable using a three conductor insulated wire (not supplied) with 

12AWG to 14AWG thickness.  Cut the power cable to the length required.
Strip approximately 3/8 of an inch of insulation from the power cable wires.
Connect the ground wire to the grounding screws on the back of the module.
Connect the power cables to the module by fastening the stripped ends to the DC 

power connector.

Содержание OmniConverter 10G/Sx 10

Страница 1: ...r can be extended to five 5 years by registering the product at www omnitron systems com support within ninety 90 days from the date of shipment During the warranty period Omnitron will at its option...

Страница 2: ...Cautions ATTENTION Observe precautions for handling electrostatic discharge sensitive devices WARNING Potential damage to equipment and personal injury WARNING Risk of electrical shock OmniConverter 1...

Страница 3: ...d with MAC learning enabled When MAC learning is disabled unicast packets are forwarded to all ports SW1 SW2 Function DOWN DOWN Switch Mode factory default DOWN UP Directed Switch Mode UP DOWN Dual De...

Страница 4: ...has been restored because no return to primary has been selected Page 8 Redundant Uplink When configured for Uplink Redundant Mode return to primary a fault on the primary Port F1 will cause a fail o...

Страница 5: ...uires 12 to 57VDC inclusive of tolerances 0 86A 12VDC max rated power The 10 Port 10G Sx requires 12 to 57VDC inclusive of tolerances 0 94A 12VDC max rated power See specification table for specific m...

Страница 6: ...nsertion b Connect an appropriate multimode or single mode fiber cable to the fiber port on the front of the module It is important to ensure that the transmit TX is attached to the receive side of th...

Страница 7: ...45 SFP SFP 10GBASE X Fiber Transceivers 10GBASE T Copper Transceivers 1000BASE X Fiber and Copper Transceivers 10 100 1000BASE T SGMII Copper Transceivers Cable Types Copper EIA TIA 568A B Cat 5 UTP a...

Страница 8: ...tact 4 kV Air 8 kV IEC 61000 4 3 RS 80 MHz to 1 GHz 3 V m IEC 61000 4 4 EFT Power 1 kV Signal 0 5 kV IEC 61000 4 5 Surge Power 1 kV Signal 1 kV IEC 61000 4 6 CS Signal 3 V IEC 61000 4 8 Magnetic Field...

Отзывы: