background image

Page 7

Dual Device Mode

When configured for Dual Device Mode, the module is configured as two logically 

independent Layer 2 switches.  On models with 4 RJ-45 user ports, Port F1 is 

associated with ports P1 and P2 and Port F2 is associated with ports P3 and P4.  

On models with 8 RJ-45 user ports, Port F1 is associated with ports P1 - P4 and 

Port F2 is associated with ports P5 - P8. Data flow will follow MAC address mapping.

Dual Device Mode

When models with 4 RJ-45 user ports are configured for Dual Device Mode and 

Directed Switch Mode, the traffic from ports P1 and P2 is only forwarded to uplink 

port F1 and ports P3 and P4 are only forwarded to uplink port F2.  When models with 

8 RJ-45 user ports are configured for Dual Device Mode and Directed Switch Mode, 

the traffic from ports P1 - P4 is only forwarded to uplink port F1 and ports P5 - P8 

are only forwarded to uplink port F2. This prevents broadcast traffic from flooding 

other network ports.  Incoming traffic from F1 and F2 follows MAC address mapping.  

Dual Device with Directed Switch Mode

SW3 and SW4:  Uplink Redundancy

The modes are described with MAC learning enabled.  When MAC learning is 

disabled, the module will send data to all ports.

SW3

SW4

Function

DOWN

DOWN

Switch Mode (factory default)

DOWN

UP

Switch Mode (factory default)

UP

DOWN

Redundant Mode - no return to primary (F1)

UP

UP

Redundant Mode - return to primary (F1)

Uplink Redundancy

When  configured  for  Uplink  Redundant  Mode  “no  return  to  primary”,  the  uplink 

ports operate as redundant links.  A fault on the primary Port F1, will cause a fail 

over to the secondary Port F2 within 50msec.  Port F1 will become the secondary 

port once the failure condition has been restored because “no return to primary” 

has been selected.

Page 8

Redundant Uplink

When configured for Uplink Redundant Mode “return to primary’, a fault on the 

primary Port F1, will cause a fail over to the secondary Port F2 within 50msec.  

The module will return to the primary Port F1 after the failure condition has been 

restored for 6 seconds.

SW5:  MAC Learning - “MAC Learning/Off”

When this DIP-switch is in the DOWN “MAC Learning” position (factory default), all 

ports on the module will learn the source MAC address of each received packet and 

store the address so packets destined for the stored addresses can be forwarded to 

the appropriate port on the module. When the DIP-switch is in the UP “Off” position, 

learning is turned off and all received unicast packets are forwarded to all ports.

SW6: Pause - “Pause Off/On”

Setting the DIP-switch to the DOWN “Pause Off” position (factory default) configures 

the module to advertise no Pause capability on all ports.  Setting this DIP-switch to the 

UP “On” position configures the module to advertise Symmetrical and Asymmetrical 

Pause capability to all ports.  

SW7: L2CP - “L2CP Tunnel/Discard”

When this DIP-switch is in the DOWN “L2CP Tunnel” position (factory default), all 

L2CP frames will be tunneled through the module.  When this DIP-switch is in the 

UP “Discard” position, all L2CP frames will be discarded.

SW8:  Reserved

2) Installing the Module

Wall Mounting

The wall mounting height of the module should be less than or equal to 2 meters 

(6.6 feet) from the floor.  Use the four mounting holes on the module to secure the 

module to the wall.  The module can accommodate #6 screws (not included).

Installation of the module should be such that the air flow in the front, back, side 

and top vents of the switch are not compromised or restricted.
The accessory cables should have their own strain relief and do not pull down on 

the module. 

Содержание OmniConverter 10G/Sx 10

Страница 1: ...r can be extended to five 5 years by registering the product at www omnitron systems com support within ninety 90 days from the date of shipment During the warranty period Omnitron will at its option...

Страница 2: ...Cautions ATTENTION Observe precautions for handling electrostatic discharge sensitive devices WARNING Potential damage to equipment and personal injury WARNING Risk of electrical shock OmniConverter 1...

Страница 3: ...d with MAC learning enabled When MAC learning is disabled unicast packets are forwarded to all ports SW1 SW2 Function DOWN DOWN Switch Mode factory default DOWN UP Directed Switch Mode UP DOWN Dual De...

Страница 4: ...has been restored because no return to primary has been selected Page 8 Redundant Uplink When configured for Uplink Redundant Mode return to primary a fault on the primary Port F1 will cause a fail o...

Страница 5: ...uires 12 to 57VDC inclusive of tolerances 0 86A 12VDC max rated power The 10 Port 10G Sx requires 12 to 57VDC inclusive of tolerances 0 94A 12VDC max rated power See specification table for specific m...

Страница 6: ...nsertion b Connect an appropriate multimode or single mode fiber cable to the fiber port on the front of the module It is important to ensure that the transmit TX is attached to the receive side of th...

Страница 7: ...45 SFP SFP 10GBASE X Fiber Transceivers 10GBASE T Copper Transceivers 1000BASE X Fiber and Copper Transceivers 10 100 1000BASE T SGMII Copper Transceivers Cable Types Copper EIA TIA 568A B Cat 5 UTP a...

Страница 8: ...tact 4 kV Air 8 kV IEC 61000 4 3 RS 80 MHz to 1 GHz 3 V m IEC 61000 4 4 EFT Power 1 kV Signal 0 5 kV IEC 61000 4 5 Surge Power 1 kV Signal 1 kV IEC 61000 4 6 CS Signal 3 V IEC 61000 4 8 Magnetic Field...

Отзывы: