Omnitron Systems Technology OmniConverter 10GPoEBT/M Скачать руководство пользователя страница 7

Page 13

Page 14

Description

15W  

IEEE 802.3af 

PoE

30W  

IEEE 802.3at 

PoE+

60W  

IEEE 802.3.bt  

PoE (Type 3)

100W  

IEEE 802.3bt 

PoE (Type 4)

Power Supply Voltage 

Range

46.0 to 57.0 VDC 51.0 to 57.0 VDC 51.0 to 57.0 VDC 53.0 to 57.0 VDC

Voltage Range at  

PSE port Output

44.0 to 56.0 VDC 50.0 to 56.0 VDC 50.0 to 56.0 VDC 52.0 to 56.0 VDC

Maximum Power from 

PoE/PSE port

15.4 watts

30 watts

60 watts

100 watts

Minimum Voltage at 

PoE/PD port input*

37.0 VDC

42.5 VDC

42.5 VDC

41.1 VDC

Minimum Power at 

PoE/PD port*

12.95 watts

25.5 watts

51 watts

71 watts

* at 100 meters using Cat5

PoE, PoE+ and 803.2bt Requirements

5) Verify Operation

Verify the module is operational by viewing the LED indicators.

NOTE:  The PSE LED may turn Amber (ON) when a non-PD device is connected 

to the port.  

Power 

LED Indicators

Legend

Indicator

Description

Pwr

OFF

Unit not powered

Green - ON

Unit powered

Green - Blinking at 1Hz

Indicates reset button has been pressed for more than 5 

seconds and the module is ready to be restored to factory 

default values

Power LED Indicator

Uplink

LED Indicators

Legend

Indicator

Description

1000

(Link)

OFF

Port not linked 

Green - ON

Port linked at the speed indicated by the Speed LED

Green - Blinking at 10Hz  Port is transmitting or receiving data
Green - Blinking at 1Hz

Port in redundant secondary mode

10G

(Speed)

OFF

Port not linked

Amber - Blinking at 1Hz

Port not linked and receiving remote fault or FEFI

Green - single blink

Port linked at 10M, 100M or 1G

Green - two blinks 

Port linked at 2.5G

Green - three blinks

Port linked at 5G

Green - four blinks

Port linked at 10G

SFP/Uplink Ports LED Indicators LED Indicators 

RJ-45 User Ports 

LED Indicators

Legend

Indicator

Description

100

OFF

No link

Green - ON

Port linked at 100Mbps

Green - Blinking at 10Hz Port data activity at 100Mbps
Amber -ON

Port linked at 100Mbps Half-duplex

Amber - Blinking at 10Hz Port data activity at 100Mbps Half-duplex

1000

OFF

No link

Green - ON

Port linked at 1000Mbps

Green - Blinking at 10Hz Port data activity at 1000Mbps
Amber -ON

Port linked at 1000Mbps Half-duplex

Amber - Blinking at 10Hz Port data activity at 1000Mbps Half-duplex

10 

OFF

No link

Green - ON

Port linked at 10Mbps

Green - Blinking at 10Hz Port data activity at 10Mbps
Amber -ON

Port linked at 10Mbps Half-duplex

Amber - Blinking at 10Hz Port data activity at 10Mbps Half-duplex

PoE/PSE

OFF

Port PSE inactive

Amber - ON

Port PSE inactive - exceeding the power source

Green - single blink

Powered by 802.3af PoE 15W

Green - two blinks 

Powered by 802.3at PoE 30W

Green - three blinks

Powered by High-Power PoE 60W

Green - four blinks

Powered by High-Power PoE 100W

RJ-45 LED Indicators

Содержание OmniConverter 10GPoEBT/M

Страница 1: ...adapter can be extended to five 5 years by registering the product at www omnitron systems com support within ninety 90 days from the date of shipment During the warranty period Omnitron will at its...

Страница 2: ...1000 RJ 45 copper Power Sourcing Power over Ethernet user ports The 10GPoEBT M is an IEEE 802 3bt compliant PoE switch featuring 60W and 100W per user port The mode of operation can be configured usi...

Страница 3: ...hes are located on the side of the module The DIP switches are used to configure modes of operation networking features and PoE reset Page 6 DIP switch Bank Locations The table below provides a descri...

Страница 4: ...to uplink port F1 and ports P3 and P4 are only Page 8 forwarded to uplink port F2 This prevents broadcast traffic from flooding other network ports Incoming traffic from F1 and F2 follows MAC address...

Страница 5: ...ve link on F2 is detected 2 Installing the Module Wall Mounting The wall mounting height of the module should be less than or equal to 2 meters 6 6 feet from the floor Use the four mounting holes on t...

Страница 6: ...power source must be connected to the terminal on the module and the negative lead of the power source to the terminal on the module as shown above Power Options WARNING Note the wire colors used in m...

Страница 7: ...z Port is transmitting or receiving data Green Blinking at 1Hz Port in redundant secondary mode 10G Speed OFF Port not linked Amber Blinking at 1Hz Port not linked and receiving remote fault or FEFI G...

Страница 8: ...C not available for models with AC DC power adapter Storage 40 to 80 C Humidity 5 to 95 non condensing Altitude 100m to 4 000m operational MTBF hours Module Only 272 000 AC DC Adapter 100 000 Warrant...

Отзывы: