background image

SmarteLight v1.0 Manual 
Revision: 1.1 

Page i 

OmniSite 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SmarteLight v1.0 Manual

 

Revision: 1.1 

Date: 8/19/2011 

 

 

Preliminary 

Version

Содержание SmarteLight

Страница 1: ...SmarteLight v1 0 Manual Revision 1 1 Page i OmniSite SmarteLight v1 0 Manual Revision 1 1 Date 8 19 2011 Preliminary Version...

Страница 2: ...2 Alarm Signal Hot and Neutral 6 4 1 3 Relay COM NC and NO 6 4 1 4 Disable Switch A and B 6 4 2 Connection Diagrams 7 4 2 1 Continuously Powered 7 4 2 2 Field Replacement 8 5 Status LEDs 9 5 1 Radio...

Страница 3: ...SmarteLight v1 0 Manual Revision 1 1 Page iii OmniSite 13 Service Contract 17 Preliminary Version...

Страница 4: ...0 Manual Revision 1 1 Page iv OmniSite Revision History Version Name Reason For Changes Date 1 0 David L Brown Initial Revision 6 30 2011 1 1 David L Brown Preliminary End User Release 8 18 2011 Preli...

Страница 5: ...eview the inspection report and inspect the items and shall authorize at its option either the repair or replacement of any non conforming products or component parts whether on warranty contract of n...

Страница 6: ...r The SmarteLight is installed at your equipment and sends a wireless signal to the local cellular tower That signal is bounced to OmniSite s web interface where customers can log on any day any time...

Страница 7: ...This manual provides the information needed to install the SmarteLight connect the input and the general usage of the product The main objectives of this guide are to provide Understanding of operati...

Страница 8: ...ry Power Voltage Range 120 VAC 20 Primary Power Current Maximum 0 1 A Alarm Signal Input Voltage Range 120 VAC 20 Alarm Signal Input Current Maximum including bulb 0 5 A Output Relay Voltage Maximum 1...

Страница 9: ...teLight v1 0 Manual Revision 1 1 Page 4 of 17 OmniSite 3 Installation 3 1 Required Tools 1 stepper bit or hole saw 7 32 drill bit 1 minimum size adjustable wrench 5 16 wrench or socket Preliminary Ver...

Страница 10: ...panel surface that was just drilled 4 Place the rubber washers over the two mounting holes that were just drilled 5 Align the SmarteLight over the two mounting holes 6 Run the wiring harness through t...

Страница 11: ...imary Power Hot and Neutral The primary power wires are used to power the enclosed cellular transmitter from a 120VAC source 4 1 2 Alarm Signal Hot and Neutral The alarm signal wires are used to power...

Страница 12: ...Revision 1 1 Page 7 of 17 OmniSite 4 2 Connection Diagrams 4 2 1 Continuously Powered Continuously powered installations are intended for new OEM applications that can utilize all features of the sys...

Страница 13: ...ight v1 0 Manual Revision 1 1 Page 8 of 17 OmniSite 4 2 2 Field Replacement Field replacement installations are intended to replace an existing alarm light in the field with a SmarteLight Preliminary...

Страница 14: ...sponding status The patterns are a series of blinks followed by a 1 second pause 5 1 Radio Status LED Patterns Pattern Description Off Radio off 2 Blink Radio is idle with good network and signal stre...

Страница 15: ...tion If primary power is restored after the system has shut down it transmits a normal heartbeat call that will indicate a primary power normal condition 6 2 Backup Battery Monitoring The SmarteLight...

Страница 16: ...age is detected and removed from the Alarm Signal wires There is 5 second alarm delay before an alarm is transmitted Although the SmarteLight has only one alarm channel several field alarms can be wir...

Страница 17: ...ressing the star key The only thing required for these recipient types is a phone number You can enter this phone number in any format as long as the area code and phone number are listed For example...

Страница 18: ...e Recipient Library If you already have added recipients and you would like to add additional contact methods for a specific contact you can click the next to their name in the library You will need t...

Страница 19: ...opdown The Callout List Manager will show in the middle of the screen To add a new list click the Add List button at the top of the window You will need to specify a unique name This is the name you w...

Страница 20: ...t You will need to provide the following information Recipient The person who will receive the alert Retries The number of times to retry a recipient This can be between 0 and 9 Time Delay The amount...

Страница 21: ...tion is not suitable Verify the system has attached to the cell network by observing the LED blink patterns described in Section 5 1 My unit will not transmit alarms and I didn t set it up on the webs...

Страница 22: ...t to OmniSite for repair What is not covered Field services to remove troubleshoot or reinstall the Omnisite cellular transmitter are NOTcovered by Omnisite Omnisite resellers or representatives Remov...

Отзывы: