Document No.: IM-1508
Revision Level: 03
Approval Date: 10-JUNE-2020
Author: T. Robinson/C Fisher
Approved By: C. Fisher
3
Hero
™
40 Amp Tap Commander
Installation Guide
If the 4 pin connector
has to be removed in
order to insert the
cable in the conduit,
strip and insert the
wires here according to
the diagram below.
Plug 4 pin connector
here as shown.
Connect wires from Power
Taps here.
6
5
4
3
2
1
SDA
SCL
5V
GND
6 PIN
CONNECTOR
4 PIN
CONNECTOR
ON
TAP COMMANDER
BLUE CONNECTOR
CONN1
ON
HERO 1
TRM6
1
2
3
4
3 2
1
6
5 4
WIRE ENTRY SIDE
1 GREEN
2 WHITE
3 RED
4 BLACK
5
6
6 PIN
CONNECTOR
ON
HERO 2
ACCESSORY
•
Plug the 6 pin connector into the designated connector on the Hero:
o
Hero 1 - TRM6 on the main board.
o
Hero 2 - ACCESSORY on the Communication Module