You can use standard factory equipment elements (such as on/off buttons, end
switches/sensors that are activated by changes in temperature or pressure values, etc.)
as contact sensors, or any additionally installed sensors. We recommend to first
examine your options of connecting to a standard device or element, and only
installing an additional sensor in case that this is not possible.

Sensors with analogue output:

25

Universal Inputs

Содержание Smart 3.0

Страница 1: ...Smart 3 0 Terminal User manual 11 02 2020...

Страница 2: ...nition key 6 Terminal 7 General Configuration Information 8 Omnicomm Configurator 8 Remote Configuration Server RCS 9 Configuring Operational Parameters 10 GPRS Connection 10 Collecting Data 11 Commun...

Страница 3: ...ing Parameters 19 Operational Set up For Remote Configuration Server 19 Identifying Terminal s SIM Card Number 20 Additional equipment 20 Fuel level sensors 20 Universal Inputs 23 Omnicomm LLD Indicat...

Страница 4: ...Omnicomm Terminal modifications differ from one another by design and type of equipment that can be connected to them This User Manual describes the Omnicomm Smart Terminal range SafetyRecommendations...

Страница 5: ...tall the SIM card holder back into the slot see the image below It is possible to custom order an option for installing a SIM chip Output Connectors Omnicomm Smart Terminal X1 connector 5 Output Conne...

Страница 6: ...LLS Blue white 6 CAN L CAN L Violet white 7 On board power voltage Power supply Red 8 Ignition key IGN Yellow 9 Universal input Input 1 Black 10 Not used NC 11 Line A RS 485 LLS A RS 485 LLS Orange w...

Страница 7: ...al must be installed inside the vehicle cabin or inside a specially designed electrical equipment box weather and precipitation proofed and fixed on the vehicle Drill 4 mounting holes 4 mm in Here is...

Страница 8: ...rator upon connecting the Terminal to a personal computer 2 Via the Remote Configuration Server RCS Initial Terminal s configuration must be performed via Omnicomm Configurator program Omnicomm Config...

Страница 9: ...Terminal operation mode Remote Configuration Server RCS Open your browser and enter http config omnicomm ru 9911 en in the URL bar to connect to the configuration server Then the window will open 9 Re...

Страница 10: ...er the password that you selected for the Terminal when configuring it via the Omnicomm Configurator in the Password field 3 Click on the button Configuring Operational Parameters GPRS Connection Open...

Страница 11: ...ss point name Phone number this stands for the telephone number associated with the SIM card installed in the Terminal APN user name and APN Password Enter your login details for the access point if y...

Страница 12: ...ngs change by more than 0 2 g or when the panic button is pressed the Terminal switches to Collect All Data mode and proceeds to transmit data to the Communication Server for the next 5 minutes When s...

Страница 13: ...g it on the map This is done by collecting additional data from the GPS module on the distance travelled between registered events with set coordinates Distance Travelled enter the value of the distan...

Страница 14: ...sending of information messages by the Terminal With the SMS parameter on specify the following Number for sending SMS select a telephone number to which the SMS with information on the Terminal and...

Страница 15: ...aluating the position of the ignition key given actual connection to the ignition key On Board Network Voltage this records the ignition being switched on or off by evaluating whether the on board net...

Страница 16: ...You will be taken to the following screen In the Engine RPM enter the number of engine revolutions according to the tachometer readings Launch the calibration by clicking on the Start Calibration butt...

Страница 17: ...connection must be one in the vehicle s electrical network where the impulse signal frequency is proportional to the engine RPM rate Accelerometer Open the Settings menu and select the Additional Equi...

Страница 18: ...tion value during speeding up which must be exceeded to recognise the driving manner as dangerous Slowdown threshold select the acceleration value during braking which must be exceeded to recongnise t...

Страница 19: ...ord when saving configurations field Password enter the password that will be used for access to settings configurations The password must contain at least 8 characters Operational Set up For Remote C...

Страница 20: ...become available for any further operations via the Remote Configuration Server Identifying Terminal s SIM Card Number The Terminal s SIM card telephone number is displayed automatically in the Remot...

Страница 21: ...icomm LLS AF fuel level sensors you will need to configure the following parameters Filters Enter the size of the internal filter you intend to use Here are the available filter options Filters Off Fi...

Страница 22: ...Connect the Omnicomm LLS 20310 fuel level sensor according to the figure below 22 IdentifyingTerminal s SIM Card Number...

Страница 23: ...nputs tab then go to Universal Inputs Universal input select On Operation mode select Potential Transmit 1 Wire Sensor Values Instead of UI Values check this box if you need to transmit data from addi...

Страница 24: ...end SMS upon triggering select On if you want the Terminal to send SMS text messages when a voltage universal input is activated Equipment name enter a parameter controlled Potential types of sensors...

Страница 25: ...hanges in temperature or pressure values etc as contact sensors or any additionally installed sensors We recommend to first examine your options of connecting to a standard device or element and only...

Страница 26: ...value for the variable measured by the sensor defined in appropriate units Voltage Associated With Maximum Value set the voltage value that should be associated with the maximum value of the measured...

Страница 27: ...Standardised voltage output Sensors with frequency output 27 Universal Inputs...

Страница 28: ...ment connected via the 1 Wire interface This will prevent data transmission from the universal input Pull up select On if you re working with open collector or contact type sensors Current Universal I...

Страница 29: ...ator Here are the available options GPS Speed Tracking displays vehicle speed Universal Input displays state of or value at the Terminal s universal input depending on the additionally connected equip...

Страница 30: ...essed Connect the panic button according to the figure below The panic button shall be installed on the vehicle s front panel or anywhere inside the vehicle cabin that is convenient for use Once you v...

Страница 31: ...31 CAN bus...

Страница 32: ...to display in Omnicomm Online by ticking the box in the Use column appropriately If you need to add parameter readings from the CAN bus that are missing from this list go to Omnicomm Configurator and...

Страница 33: ...e offset value in relation to the basic address of the bit storage area You can choose values from 0 to 63 SPN Enter the parameter code according to SAE J1939 You can choose between values from 0 to 4...

Страница 34: ...k from CAN bus readings select the Collect Data During Joilting Terminal operation mode for the event of ignition Off Otherwise the fuel chart will display inaccurate information Technical Specificati...

Страница 35: ...olatile data memory events 150 000 Omnicomm Smart Inputs and outputs Ignition key input Yes RPM sensor input Yes Number of universal inputs Yes Interfaces CAN interface Yes RS 485 interface Yes USB in...

Страница 36: ...type Buit in Features Fuel level sensors connection 1 Remote GPRScontrol Yes Data output via external indicator Yes SMSnotifications Yes Omnicomm Smart Connection SMS commands SMS commands for Termin...

Страница 37: ...DID device ID HW code_hardware_version BL loader_version FW wiring_version REC number_of_archived_records IMEI unique_identificator_of_GSM_modem Enquiry on the terminal state RESET RESETparam Possibl...

Страница 38: ...e Terminal s ID pwdid is password identificator SETPWDID ERRID ERRNulPWD ERRAlrSet PWD pwdid OK Setting the password parameter CONNECTSC RESETparam Possible parameter readings param OK when command is...

Страница 39: ...info omnicomm world com www omnicomm world com...

Отзывы: