![Omnicomm LLS-Ex 5 Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/omnicomm/lls-ex-5/lls-ex-5_user-manual_739205009.webp)
Overall dimensions (without cables), mm
138 х 115 х 56
Weight, not more than, kg
0.9
Average service life, years
8
Parameter
Value
Electrical Parameters of Intrinsic Safety
Omnicomm LLS-Ex 5 sensor
Parameter name
Value
Maximum input voltage, Ui, V
5.5
Maximum input current, Ii, A
0.06
Maximum internal capacity, Ci, µF
10
Maximum internal inductance Li, mH
0.5
Special conditions for safe operation of
Omnicomm LLS-Ex 5
In order to avoid ignition from frictional sparks (which appear from friction or collision), it
is recommended to install at places which restrict access to the exterior parts of the fuel
sensor. It is necessary to protect the sensors body from accidental shocks or friction.
It is recommended to use a protective seal cover.
It is not recommended to use a sensor with the damaged paint coating.