OmniTrack Installation and Programming Instructions
Programming the OmniTrack
OmniTrack Installation Guide
/67-2055 Rev A
© 2009 Omnicell, Inc.
The OmniTrack can be addressed like a switchpanel with button numbers from 0-31 (one zone =
five switchpanels each having eight item buttons); or like a supply drawer with button numbers
from 40 - 199. These two types of addressing make it possible to use the OmniTrack in any zone
with any configuration.
Switchpanel Bin Type
Use the switchpanel bin addressing when using the OmniTrack with a SecureTrack or to keep
track of off-Omni supplies. In this instance, the OmniTrack is set to a different zone than its
actual physical location and will not conflict with shelves or drawers.
Supply Drawer Bin Type
Use supply drawer bin addressing when using the OmniTrack in a pharmacy zone, where
Pre-
select
is required. Supply drawer bin numbering enables the OmniTrack to be set to a zone on the
physical OmniSupplier and allows the OmniTrack to be used with other shelves and supply
drawers in that same zone. Set the Zone Address to the same zone as the Host Zone Address.
Using this bin type, the host location addressing set in the second row is not important. Instead
you must set the supply drawer location i.e. the row in which the OmniTrack is installed. The row
location is set by the first three item buttons from the left in the third row from the top. The same
type of binary numbering/addressing applies. With the current OmniSupplier software, only 5
supply drawers are possible. A supply drawer has 3 switchpanels, thus 5*3 = 15, the software can
recognize 15 switchpanels. Since the OmniTrack has 4 switchpanels, 15/4 = 3.75, only the first
three supply drawer locations can be used for addressing the OmniTrack.
Figure 1-14.
Note:
Do not use pharmacy
Pre-select
in this configuration. When requesting drugs from a shelf and
an OmniTrack located behind the same door, you will have to open and close the door after getting the
drugs from the shelf before the drugs on the OmniTrack are available. (Problem: two zones behind one
door).
Note:
If the OmniTrack is set for switchpanel addressing, it only leaves the fifth shelf location addresses
open. So there could only be one shelf, in the fifth position, and one OmniTrack. The controller on the
SPC wireway would also conflict with the controller on the OmniTrack. (Problem: conflicting addressing
and controllers.)
Note:
Supply Drawer addressing does NOT work with SecureTrack. Drawers do not look for door
commands.