Page 27
OMNI by EconoHeat
Boiler Jacket Assembly
OWB-35 and OWB-50 Jacket Installation Instructions
• Screw the four extension setscrews (43) into the four outer holes in the corners of the rear
sections. Securely tighten the setscrews and other fastening bolts of the flue outlet cover
(22)
• Place the large wraparound insulation mat (40) over boiler block (aluminum foil side
facing out).
• Place smaller piece of insulation on top of wraparound insulation. This will provide double
thick insulation on top of the boiler block.
• Remove flue collector clean-out covers (62)
• Push the two smaller pieces of insulation (60) onto the flue collector (22) so that the four
extension setscrews (43) protrude through the insulation.
• Attach rear jacket panels (36) and (38) to the two extension screws(43) using the M6x10
pan head screws. Screw the rear panels together in the center using sheet metal screws
provided. Reattach the clean-out covers.
• Place right and left side panels (93) (94) into the factory mounted hinge bracket (18) and
hook into the rear panels (36) (38).
• Hook center panel (33) with flange edge down between side panels (93) and (94).
• Attach the upper front trim panel (41) between the right and left side panels over the
front door.
• Place the top
panel (86) in
position. Hook
to the side
panels.
• Remove sight
glass plug in
front door and
install sight
glass assembly.
Sight Glass (25)
Sight Glass
Tube Cap(26)
and Sight Class
Gasket(48).
26
25 26A
48
94
86
33
60
38
36
43
93
40
18
18
41
Figure 30
– OWB-35 and OWB-50 Assembly Detail