background image

3

WARRANTY INFORMATION

This manual is a guide for the use of the Bead Ruptor 24 Bead Mill Homogenizing System and accessories. 

Data herein has been verified and validated. It is believed adequate for the intended use of the instrument. 
If the instrument or procedures are used for purposes over and above the capabilities specified herein, 
confirmation of the validity and suitability should be obtained, otherwise Omni International does not 
guarantee results and assumes no obligation or liability. This publication is not a license to operate under, 
or a recommendation to infringe upon, any process patents. 

Notes, cautions, and warnings within the text of this manual are used to emphasize important and critical 
instructions.

This Omni International product is warranted to be free from defects in material and workmanship for a 
period of ONE YEAR from the date of delivery. Omni International will repair or replace and return free of 
charge any part which is returned to its factory within said period, transportation prepaid by user, and which 
is found upon inspection to have been defective in materials or workmanship. For the first 90 days, both 
parts and service are without charge. For the balance of the period, parts will be provided but service will be 
charged at established labor rates. This warranty does not include normal wear from use;  it does not apply 
to any instrument or parts which have been altered by anyone other than an employee of Omni 
International nor to any instrument which has been damaged through accident, negligence, failure to follow 
operating instructions, the use of electric currents or circuits other than those specified on the plate affixed 
to the instrument, misuse, or abuse. Omni International reserves the right to change, alter, modify, or 
improve any of its instruments without any obligation whatever to make corresponding changes to any 
instrument previously sold or shipped.

THE FORGOING OBLIGATION IS IN LIEU OF ALL OBLIGATIONS AND LIABILITIES INCLUDING NEGLIGENCE AND 
ALL WARRANTIES OF MERCHANTABILITY OR OTHERWISE, EXPRESSED OR IMPLIED IN FACT OR BY LAW, AND 
STATE OUR ENTIRE AND EXCLUSIVE LIABILITY AND BUYERS EXCLUSIVE REMEDY FOR ANY CLAIM OF 
DAMAGES IN CONNECTION WITH THE SALE OR FURNISHING OF GOODS OR PARTS, THEIR DESIGN, 
SUITABILITY FOR USE, INSTALLATION, OR OPERATION. OMNI INTERNATIONAL WILL IN NO EVENT BE LIABLE 
FOR ANY SPECIAL OR CONSEQUENTIAL DAMAGES WHATSOEVER, AND THEIR LIABILITY UNDER NO 
CIRCUMSTANCES WILL EXCEED THE CONTRACT PRICE FOR THE GOODS FOR WHICH LIABILITY IS CLAIMED.

Содержание Bead Ruptor 24

Страница 1: ......

Страница 2: ...Information 16 SECTION 4 SET UP OPERATION 4 1 Loading Sample Tubes 17 19 4 2 Keypad Layout 20 4 3 Start Up of the Equipment 20 4 4 Speed Setting 21 4 5 Temperature Sensor 21 SECTION 5 PROGRAMMING 5 1...

Страница 3: ...are without charge For the balance of the period parts will be provided but service will be charged at established labor rates This warranty does not include normal wear from use it does not apply to...

Страница 4: ...aboratory DO NOT plug power cord into an incorrect outlet Keep this product away from heated surfaces To reduce the risk of burns electrocution fire or injury Use this product only for its intended pu...

Страница 5: ...he inner cardboard box 5 Unscrew the two external knob screws from the back of the unit to release from the support plate 6 Slide the Bead Ruptor away from the knob screw holes 7 Lift the unit up and...

Страница 6: ...tlet that is properly installed and grounded in accordance with all local codes and ordinances WARNING DO NOT modify the plug or cord that is provided Damaged or worn power cords should be repaired or...

Страница 7: ...7 2 2 UNIT OVERVIEW Keypad Lid Latch Finger Plate Lock Switch Finger Plate Tube Carriage Lid 120V 220V Switch Fuse ON Off Switch AC Power Input Shipping Screw Holes SECTION 2 UNPACKING THE BEAD RUPTOR...

Страница 8: ...r Plate that holds the 1 5 mL microtubes firmly in place during processing 2 mL TUBE CARRIAGE KIT P N 19 010 310 Holds 24 x 2 mL or 24 x 0 5 mL skirted tubes Includes Bead Ruptor Finger Plate that hol...

Страница 9: ...mplifies the tube loading process and enables storage of loaded Tube Carriages before and after processing down to 80 C BEAD RUPTOR RACK P N 19 604 The optional Bead Ruptor Rack simplifies the tube lo...

Страница 10: ...for the 1 2 mL strip well tube carriage is 5 m s The 96 x 1 2ml strip well tube carriage is not compatible with the BR Cryo lid 24 x 1 5 mL microtubes 1 5 mL Microtube volume and tissue size Minimum...

Страница 11: ...tube carriage is not compatible with the BR Cryo lid 6 x 30 mL screw cap tubes 30 mL Tube Volume and Tissue Size Minimum 4 mL 1 g Maximum 30 mL up to 20 g CAUTION The maximum recommended speed for th...

Страница 12: ...0 19 617 1 5 mL 0 5 mm Tough Micro organism Lysing Matrix 50 19 612 BEAD MEDIA Ceramic Glass Bulk Sample Tubes No Beads Empty 1 5 mL microtubes Beads are not included TUBE SIZE DESCRIPTION QUANTITY OR...

Страница 13: ...rd Tissue Grinding Mix 50 19 620 BEAD MEDIA Glass Garnet Carbide Ceramic Metal SECTION 3 BEAD RUPTOR SAMPLE TUBES 3 2 ORDERING INFORMATION 2 mL 0 5 mL SCREW CAP PRE FILLED BEAD MILL TUBES Bulk 2 mL 0...

Страница 14: ...5 g Empty Sample Tubes with Bulk Soft Tissue Homogenizing Bead Mix 50 19 652 7 mL 2 8 mm 325 g Empty Sample Tubes with Bulk Hard Tissue Homogenizing Bead Mix 50 19 653 7 mL 2 38 mm 500 g Empty Sample...

Страница 15: ...1 4 Ceramic 50 19 6358Z BEAD MEDIA Metal Ceramic Bulk 30 mL Screw Cap Sample Tubes No Beads Empty sample tubes with caps Beads are not included TUBE SIZE DESCRIPTION QUANTITY ORDER NUMBER 30 mL Polyp...

Страница 16: ...solutions Use the tubes as single use or disposable Add more buffer to decrease the force applied by the beads to the tube walls Open the Bead Ruptor s lid for 5 to 10 minutes in order to cool down t...

Страница 17: ...etched into the tube carriage Beyond those locations the user may load additional tubes in any position without the need to balance the remaining tubes CAUTION DO NOT run the Bead Ruptor without movin...

Страница 18: ...Bead Ruptor 15 mL tubes into the Tube Carriage 2 Place the tube carriage onto the Drive Hub 3 Screw the locking ring on tightly 4 Engage the lock 7 mL Tube Carriage 15 mL Tube Carriage Lock Ring Lock...

Страница 19: ...run unit without engaging the lock first 30 mL Configuration 1 Place Bead Ruptor 30 mL tubes into the Tube Carriage 2 Place the tube carriage onto the Drive Hub 3 Screw the locking ring on tightly 4...

Страница 20: ...n choose from F French E English G German I Italian S Spanish After five seconds of the welcome screen a menu displays the programming mode Programming mode displays the last program run before power...

Страница 21: ...the motion of the tube carriage the bead media and the tube fill volume The S display in meters per second refers to the maximum vertical velocity achieved by a sample tube during reciprocating proce...

Страница 22: ...or READY SPEED m s CYCLE TIME NUMBER OF CYCLES PAUSE DWELL PARAMETER OPERATING RANGE Speed Energy From 0 8 m s to 8 m s in increments of 0 15 m s Time From 0 01 to 9 59 in increments of 1 second Numb...

Страница 23: ...desired variable or go back up to Program to begin the run The S Speed of the Bead Ruptor is displayed in m s which is a specific representation of the forces applied to the sample due to the velocity...

Страница 24: ...ight the D Pause Dwell option The user can change the Dwell time between 2 or more cycles using the and Arrow buttons The dwell time between cycles ranges from 0 seconds to 9 minutes and 59 seconds in...

Страница 25: ...can damage the finish of the housing and lid DO NOT autoclave the finger plate This will cause it to crack Instead wipe the space fingerplate down with a damp cloth and a mild detergent Example of Dec...

Страница 26: ...Check main voltage 2 Check that the voltage of the unit matches that being delivered by the main power supply 3 Make sure the unit is plugged in properly 4 Check and replace fuses if blown Faulty dis...

Страница 27: ...of the shipping crate 3 Lower the unit onto the hooks and slide it backward until the back of the unit touches the supporting edge 4 Secure the unit to the support plate with the included knob screws...

Страница 28: ...pment Obtain a Decontamination Certificate from Omni International Complete the certificate and attach to the instrument or parts being returned If no Decontamination Certificate is attached and a pot...

Страница 29: ...PROVAL COMPLIANCE CE certified The Cryo 24 is the perfect companion to the Bead Ruptor 24 It keeps samples cool before after during processing Used with liquid nitrogen or dry ice it maintains a consi...

Страница 30: ...30 NOTES...

Страница 31: ...31 NOTES...

Страница 32: ......

Отзывы: