background image

 

 

DMAN-xxxx-xx

 

www.omnexcontrols.com

 

call toll free: 1-800-663-8806

 

The ORIGA T2300 / R2160 / D180 is a portable, long range, programmable radio remote control system.  Designed 
as a compact and easy-to-use product, this member of the ORIGA family puts complete control of your crane where 
it’s needed most, with the operator.  It’s robust, easy to install and has complete self-diagnostics.  This system can be 
a simple cable replacement or add intelligence to make it a total control package.  It’s a radio, a PLC and a valve 
driver all in one. 

 
The ORIGA T2300 R2160 / D180 system uses Frequency Hopping Spread Spectrum (FHSS) technology.  FHSS de-
vices concentrate their full power into a very narrow signal that randomly hops from frequency to frequency within a 
designated band.  This transmission pattern, along with CRC-16 error-checking techniques, enables signals to over-
come interference that commonly affects licensed radios. 
 
The R2160 receiver is designed to be powered from a 12VDC or 24VDC system.  It features 19 solid state, high-side 
driver input / output controls and a reliable E-Stop control. 
 
The D180 Expansion Unit has up to fourteen current-control, PWM, or voltage outputs, or a combination of these 
types.   
 
The T2300 transmitter comes with up to sixteen proportional and sixteen digital controls.  The T2300 can accommo-
date up to eight single axis paddles, eight three-position switches and a re-settable E-Stop. A unique ID code is used 
by each T2300 to ensure that no two systems will conflict on a job site. 

STOP 

Power/Calibration  
switch 

E-Stop 

Switches 2 - 8 

E-Stop LED 

Link LED 

Battery/
Pendant LED 

Paddles 1 - 8 

Pendant connector 

T2300 Dimensions and Controls 

9.5” 

6.0” 

Features 

 

• 

FCC, ISC, CE approved 

• 

License free 

• 

900 foot range @ 2.4 GHz 

• 

Compact / weatherproof / ergonomic 

• 

Simple “wire-and-use” installation 

• 

Resilient to impact and shock 

• 

Available with paddles and/or joysticks for propor-
tional control 

• 

Available with an optional pendant cable 

• 

Factory configurable for all custom applications. 

T2300 Transmitter 

R2160 Receiver 

D180 Module 

 System Overview

 

 

LCD Screen and Controls 

Содержание T2300

Страница 1: ...06 GENERIC Installation Configuration Manual T2300 Transmitter R2160 Receiver D180 Expansion Module 74 1833 Coast Meridian Road Port Coquitlam BC Canada V3C 6G5 Ph 604 944 9247 Fax 604 944 9267 Toll F...

Страница 2: ...e 8 LCD Display Operation 10 Calibrating Proportional Controls 11 Diagnostics T2300 Transmitter 12 Diagnostics D180 Expansion Module 12 Diagnostics R2160 Receiver 13 Troubleshooting Guide 14 Parts Acc...

Страница 3: ...ty MAKE SURE MACHINERY AND SURROUNDING AREA IS CLEAR BEFORE OPERATING Do not activate the remote system unless it is safe to do so TURN OFF THE RECEIVER POWER BEFORE WORKING ON MACHINERY Always discon...

Страница 4: ...r is designed to be powered from a 12VDC or 24VDC system It features 19 solid state high side driver input output controls and a reliable E Stop control The D180 Expansion Unit has up to fourteen curr...

Страница 5: ..._____________ ________________ ________________ ________________ ________________ ________________ ________________ ________________ Functions Factory Configurable Only Factory Configurable Only Input...

Страница 6: ...________ ________________ ________________ ________________ ________________ Functions Factory Configurable Only Factory Configurable Only Unused Output Unused Output Unused Output Unused Output Unuse...

Страница 7: ...cting the power from the charging side of existing wiring or making use of existing ACC or other peripheral connection points Make sure that wire of sufficient gauge and insulator type is used when co...

Страница 8: ...00 If the Active light on the transmit ter is flashing and the Link light on the receiver is flashing GREEN a link between the two exists The E Stop light and the Link light will come on RED provided...

Страница 9: ...light goes from slow flash to fast flash B Release Setup button Status light goes to solid GREEN Link light turns off ESTOP FAULT LINK STATUS Setup Button A ESTOP FAULT LINK STATUS Setup Button B 5 P...

Страница 10: ...y Operations The LCD display contains a 9 button keypad For this version the bottom left button is operational Pressing this button toggles the LCD backlight feature to either ON or OFF Note Leaving t...

Страница 11: ...ps 3 4 by holding the Power switch UP or DOWN for 5 seconds A Refer to steps in Power the Transmitter B Supply power to the R2160 B ESTOP FAULT LINK STATUS 1 Power T2300 Power R2160 A Hold Power switc...

Страница 12: ...power up the transmitter or the unit will power down On Power Up Press and release the E Stop button within 10 seconds to power up the transmitter or the unit will power down The transmitter is in Cal...

Страница 13: ...ent draw on an output It is most likely caused by a wiring fault Ensure transmitter is functioning properly check status of each output connection Press each function button and observe Fault Light If...

Страница 14: ...t changes to GREEN there is a short is the wiring after the discon nection point Stays flashing RED call for service What is the state of the Fault light Fault Light is OFF Fault Light is Flashing RED...

Страница 15: ...Does the Active light go to solid YELLOW YES Either the switch paddle is defective or the switch paddle connection to the circuit board is broken Call for service Complete the following steps in orde...

Страница 16: ...nsmitter to check if the units function correctly If not proceed to Chart 1 NO YES The transmitter code may need to be re downloaded to the receiver NO Caution Note Before you proceed with the Downloa...

Страница 17: ...from the transmitter Possible Solutions 1 Try the Downloading steps again 2 If this doesn t correct the problem send both the transmitter and receiver in for service Note you could try to determine wh...

Страница 18: ...trap ACAB 2493 01 R2160 Output Cable Generic ACAB 2493 03 R2160 Output Cable Generic Tethered Pendant Cable ACAB 2455 01 Tether Cable 10m ACAB 2455 02 Tether Cable 8m ACAB 2710 01 Tether Cable 4 12ft...

Страница 19: ...e sired operation FCC Part 15 247 ISC RSS 210 Issue 6 Sept 2005 Warranty OMNEX Control Systems ULC warrants to the original purchaser that the OM NEX products are free from defects in materials and wo...

Отзывы: