background image

 

16 

 

DMAN-xxxx-xx

 

www.omnexcontrols.com

 

call toll free: 1-800-663-8806

 

Testing the Transmitter / Receiver Communication 

What is the status of 
the lights of both the 

transmitter and  

receiver? 

Transmitter: 
Active light is flashing 
 
Receiver: 
Status—GREEN 
Link—Flashing GREEN 
Fault—OFF 
E-Stop—GREEN 

Transmitter: 
Active light is flashing 
 
Receiver: 
Status—GREEN 
Link—RED 
Fault—OFF 
E-Stop—RED 

There is no link between the 
transmitter and receiver 

Do you have a 

matched set? (i.e. the 

transmitter and re-

ceiver should have 

identical ID codes 

YES 

NO 

Was the transmitter 

accidentally swapped 

with another one on 

the job site? 

Search the job site for 
the correct transmitter.   

POSSIBLY 

Transmitter and receiver 
should be working properly.  
The problem may rest with 
the machine instead of the 
radio system 
 
Call for service 

Was it found? 

Turn on the transmitter 
to check if the units 
function correctly.  If 
not, proceed to Chart 1 

NO 

YES 

The transmitter 
code may need to 
be re-downloaded 
to the receiver 

NO 

!!Caution!! 

 

Note:  Before you proceed with the Download ID procedure located on Page 7 & 8, great 
care and caution must be adhered to. Also, refer to Chart #4 for Tips and Considerations. 
 
If by accident, the transmitters have been switched with another unit, by downloading the 
ID code to a new receiver, it is possible for the transmitter to operate 2 units at the same 
time (if the original receiver unit is still on the job site).  Therefore it must be  
certain that the transmitter / receiver pair are the correct set. 
 
Secondly, once the download procedure is completed, ensure all other units on the job site 
are stopped.  Test the operation of the newly configured set to ensure no other  
machines on the site work with the same transmitter. 
 
Once you are certain that the transmitter / receiver pair are a unique set, continue  
normal operations. 

Call for service. 

Troubleshooting Guide (con’t) 

Chart #3 

Содержание T2300

Страница 1: ...06 GENERIC Installation Configuration Manual T2300 Transmitter R2160 Receiver D180 Expansion Module 74 1833 Coast Meridian Road Port Coquitlam BC Canada V3C 6G5 Ph 604 944 9247 Fax 604 944 9267 Toll F...

Страница 2: ...e 8 LCD Display Operation 10 Calibrating Proportional Controls 11 Diagnostics T2300 Transmitter 12 Diagnostics D180 Expansion Module 12 Diagnostics R2160 Receiver 13 Troubleshooting Guide 14 Parts Acc...

Страница 3: ...ty MAKE SURE MACHINERY AND SURROUNDING AREA IS CLEAR BEFORE OPERATING Do not activate the remote system unless it is safe to do so TURN OFF THE RECEIVER POWER BEFORE WORKING ON MACHINERY Always discon...

Страница 4: ...r is designed to be powered from a 12VDC or 24VDC system It features 19 solid state high side driver input output controls and a reliable E Stop control The D180 Expansion Unit has up to fourteen curr...

Страница 5: ..._____________ ________________ ________________ ________________ ________________ ________________ ________________ ________________ Functions Factory Configurable Only Factory Configurable Only Input...

Страница 6: ...________ ________________ ________________ ________________ ________________ Functions Factory Configurable Only Factory Configurable Only Unused Output Unused Output Unused Output Unused Output Unuse...

Страница 7: ...cting the power from the charging side of existing wiring or making use of existing ACC or other peripheral connection points Make sure that wire of sufficient gauge and insulator type is used when co...

Страница 8: ...00 If the Active light on the transmit ter is flashing and the Link light on the receiver is flashing GREEN a link between the two exists The E Stop light and the Link light will come on RED provided...

Страница 9: ...light goes from slow flash to fast flash B Release Setup button Status light goes to solid GREEN Link light turns off ESTOP FAULT LINK STATUS Setup Button A ESTOP FAULT LINK STATUS Setup Button B 5 P...

Страница 10: ...y Operations The LCD display contains a 9 button keypad For this version the bottom left button is operational Pressing this button toggles the LCD backlight feature to either ON or OFF Note Leaving t...

Страница 11: ...ps 3 4 by holding the Power switch UP or DOWN for 5 seconds A Refer to steps in Power the Transmitter B Supply power to the R2160 B ESTOP FAULT LINK STATUS 1 Power T2300 Power R2160 A Hold Power switc...

Страница 12: ...power up the transmitter or the unit will power down On Power Up Press and release the E Stop button within 10 seconds to power up the transmitter or the unit will power down The transmitter is in Cal...

Страница 13: ...ent draw on an output It is most likely caused by a wiring fault Ensure transmitter is functioning properly check status of each output connection Press each function button and observe Fault Light If...

Страница 14: ...t changes to GREEN there is a short is the wiring after the discon nection point Stays flashing RED call for service What is the state of the Fault light Fault Light is OFF Fault Light is Flashing RED...

Страница 15: ...Does the Active light go to solid YELLOW YES Either the switch paddle is defective or the switch paddle connection to the circuit board is broken Call for service Complete the following steps in orde...

Страница 16: ...nsmitter to check if the units function correctly If not proceed to Chart 1 NO YES The transmitter code may need to be re downloaded to the receiver NO Caution Note Before you proceed with the Downloa...

Страница 17: ...from the transmitter Possible Solutions 1 Try the Downloading steps again 2 If this doesn t correct the problem send both the transmitter and receiver in for service Note you could try to determine wh...

Страница 18: ...trap ACAB 2493 01 R2160 Output Cable Generic ACAB 2493 03 R2160 Output Cable Generic Tethered Pendant Cable ACAB 2455 01 Tether Cable 10m ACAB 2455 02 Tether Cable 8m ACAB 2710 01 Tether Cable 4 12ft...

Страница 19: ...e sired operation FCC Part 15 247 ISC RSS 210 Issue 6 Sept 2005 Warranty OMNEX Control Systems ULC warrants to the original purchaser that the OM NEX products are free from defects in materials and wo...

Отзывы: