Omnex GENERIC T300 Скачать руководство пользователя страница 2

 

 

DMAN-xxxx-xx

 

www.omnexcontrols.com

 

call toll free: 1-800-663-8806

 

System Overview  .........................................................................................................................................................3 

Features........................................................................................................................................................................3 

T300 Dimensions and Controls ....................................................................................................................................3 

Installing the Receiver ..................................................................................................................................................4 

Receiver Dimensions ....................................................................................................................................................4 

Installing the Expansion Module ...................................................................................................................................5 

Installation Considerations............................................................................................................................................6 

Power the Transmitter ..................................................................................................................................................6 

Test the Transmitter / Receiver Link.............................................................................................................................7 

Download ID Code........................................................................................................................................................7 

Calibrating Proportional Controls..................................................................................................................................9 

Diagnostics—T300 Transmitter ....................................................................................................................................10 

Diagnostics—D160 Expansion Module ........................................................................................................................10 

Diagnostics—R160 Receiver........................................................................................................................................11 

Troubleshooting Guide .................................................................................................................................................12 

Parts & Accessories......................................................................................................................................................16 

Specifications................................................................................................................................................................16 

Warranty Information ....................................................................................................................................................16

 

NOTE: These instructions are intended only for installing and operating the remote control equipment described here. This is not a 
complete Operator’s Manual.  For complete operating instructions, please read the Operator’s Manual appropriate for your particular 
machine.

 

 

READ ALL INSTRUCTIONS 

 

CAUTION: Changes or modifications not expressly approved by the party responsible for compliance could void the 
user's authority to operate the equipment. 

 

Failure to follow the SAFETY PRECAUTIONS may result in radio equipment failure and serious personal injury 

 

Installation 

 

PROVIDE A SAFETY CUTOFF SWITCH.  If maintenance is required, the radio must be disconnected from power  

 

USE PROPER WIRING.  Loose or frayed wires can cause system failure, intermittent operation, machine damage, etc. 

 

DO NOT INSTALL IN HOT AREAS.  This apparatus can be damaged by heat in excess of 158° F (70° C) 

 
 

Personal Safety 

 

MAKE SURE MACHINERY AND SURROUNDING AREA IS CLEAR BEFORE OPERATING.  Do not activate the remote 
system unless it is safe to do so. 

 

TURN OFF THE RECEIVER POWER BEFORE WORKING ON MACHINERY.  Always disconnect the remote system 
before doing any maintenance to prevent accidental operation of the machine 

 
 

Care 

 

KEEP DRY.  Do not clean the transmitter / receiver under high pressure.  If water or other liquids get inside the transmit-
ter battery or receiver compartment, immediately dry the unit. Remove the case and let the unit air dry 

 

CLEAN THE UNIT AFTER OPERATION.  Remove any mud, dirt, concrete, etc. from the unit to prevent clogging of but-
tons, switches, etc. by using a damp cloth. 

 
 

Maintenance / Welding 

 

DISCONNECT THE RADIO RECEIVER BEFORE WELDING on the machine the receiver is connected to. Failure to dis-
connect will result in the destruction of the radio receiver.  

 

Table of Contents

 

 

 

Safety Precautions

 

 

StockCheck.com

Downloaded from StockCheck.com

Содержание GENERIC T300

Страница 1: ...IC Installation Configuration Manual T300 Transmitter R160 Receiver D160 Expansion Module 74 1833 Coast Meridian Road Port Coquitlam BC Canada V3C 6G5 Ph 604 944 9247 Fax 604 944 9267 Toll Free 1 800...

Страница 2: ...ersonal injury Installation PROVIDE A SAFETY CUTOFF SWITCH If maintenance is required the radio must be disconnected from power USE PROPER WIRING Loose or frayed wires can cause system failure intermi...

Страница 3: ...ystem It features 19 solid state high side driver input output controls and a reliable E Stop control The D160 Expansion Unit has up to 19 input output including 2 proportional combinations PWM or vol...

Страница 4: ..._________ ________________ ________________ ________________ ________________ ________________ ________________ Functions Factory Configurable Only Factory Configurable Only Input Output Input Output...

Страница 5: ..._________ ________________ ________________ ________________ ________________ ________________ ________________ ________________ Functions Factory Configurable Only Factory Configurable Only Input Out...

Страница 6: ...ke sure that wire of sufficient gauge and insulator type is used when connecting the outputs of the receiver to the con trol panel Observe any component manufacturer s instructions and recommendations...

Страница 7: ...transmitter is off and the Status light will come on GREEN NOTE The transmitter will shut itself off and the receiver will then shut off all outputs after 4 hours of inactivity as a battery saving fea...

Страница 8: ...up Button A ESTOP FAULT LINK STATUS Setup Button B 5 Put R160 into Setup Mode 6 Download ID Code ESTOP FAULT LINK STATUS A Press Power switch UP and release B Link light goes to GREEN Once complete Li...

Страница 9: ...0 B ESTOP FAULT LINK STATUS 1 Power T300 Power R160 A Hold Power switch DOWN for 5 seconds until the Battery LED goes to alter nating RED and YELLOW B Release Power switch 2 Setup T300 into Configurat...

Страница 10: ...e unit will power down The transmitter is in Calibration mode STOP STOP STOP STOP STOP STOP STOP STOP STOP STOP Light Legend Solid Slow Flash Fast Flash Red Light Green Light Alternating Red Yellow Li...

Страница 11: ...t is most likely caused by a wiring fault Ensure transmitter is functioning properly check status of each output connection Press each function button and observe Fault Light If GREEN everything is OK...

Страница 12: ...e is a short is the wiring after the discon nection point Stays flashing RED call for service What is the state of the Fault light Fault Light is OFF Fault Light is Flashing RED Fault Light is RED Cal...

Страница 13: ...o to solid YELLOW YES Either the switch paddle is defective or the switch paddle connection to the circuit board is broken Call for service Complete the following steps in order 1 Check battery orient...

Страница 14: ...units function correctly If not proceed to Chart 1 NO YES The transmitter code may need to be re downloaded to the receiver NO Caution Note Before you proceed with the Download ID procedure located o...

Страница 15: ...ssible Solutions 1 Try the Downloading steps again 2 If this doesn t correct the problem send both the transmitter and receiver in for service Note you could try to determine whether the fault lies wi...

Страница 16: ...he FCC Rules Operation is subject to the following two condi tions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that...

Отзывы: