Testing the Transmitter / Receiver Communication 

What is the status of 
the lights of both the 

transmitter and  

receiver? 

Transmitter: 
Active light is flashing 
 
Receiver: 
Status—GREEN 
Link—Flashing GREEN 
Fault—OFF 
E-Stop—GREEN 

Transmitter: 
Active light is flashing 
 
Receiver: 
Status—GREEN 
Link—RED 
Fault—OFF 
E-Stop—RED 

There is no link between the 
transmitter and receiver 

Do you have a 

matched set? (i.e. the 

transmitter and re-

ceiver should have 

identical ID codes 

YES 

NO 

Was the transmitter 

accidentally swapped 

with another one on 

the job site? 

Search the job site for 
the correct transmitter.   

POSSIBLY 

Transmitter and receiver 
should be working properly.  
The problem may rest with 
the machine instead of the 
radio system 
 
Call for service 

Was it found? 

Turn on the transmitter 
to check if the units 
function correctly.  If 
not, proceed to Chart 1 

NO 

YES 

The transmitter 
code may need to 
be re-downloaded 
to the receiver 

NO 

!!Caution!! 

 

Note:  Before you proceed with the Download ID procedure located on Page 7 & 8, great 
care and caution must be adhered to. Also, refer to Chart #4 for Tips and Considerations. 
 
If by accident, the transmitters have been switched with another unit, by downloading the 
ID code to a new receiver, it is possible for the transmitter to operate 2 units at the same 
time (if the original receiver unit is still on the job site).  Therefore it must be  
certain that the transmitter / receiver pair are the correct set. 
 
Secondly, once the download procedure is completed, ensure all other units on the job site 
are stopped.  Test the operation of the newly configured set to ensure no other  
machines on the site work with the same transmitter. 
 
Once you are certain that the transmitter / receiver pair are a unique set, continue  
normal operations. 

Call for service. 

Troubleshooting Guide (con’t) 

Chart #3 

StockCheck.com

Downloaded from StockCheck.com

Содержание GENERIC T300

Страница 1: ...IC Installation Configuration Manual T300 Transmitter R160 Receiver D160 Expansion Module 74 1833 Coast Meridian Road Port Coquitlam BC Canada V3C 6G5 Ph 604 944 9247 Fax 604 944 9267 Toll Free 1 800...

Страница 2: ...ersonal injury Installation PROVIDE A SAFETY CUTOFF SWITCH If maintenance is required the radio must be disconnected from power USE PROPER WIRING Loose or frayed wires can cause system failure intermi...

Страница 3: ...ystem It features 19 solid state high side driver input output controls and a reliable E Stop control The D160 Expansion Unit has up to 19 input output including 2 proportional combinations PWM or vol...

Страница 4: ..._________ ________________ ________________ ________________ ________________ ________________ ________________ Functions Factory Configurable Only Factory Configurable Only Input Output Input Output...

Страница 5: ..._________ ________________ ________________ ________________ ________________ ________________ ________________ ________________ Functions Factory Configurable Only Factory Configurable Only Input Out...

Страница 6: ...ke sure that wire of sufficient gauge and insulator type is used when connecting the outputs of the receiver to the con trol panel Observe any component manufacturer s instructions and recommendations...

Страница 7: ...transmitter is off and the Status light will come on GREEN NOTE The transmitter will shut itself off and the receiver will then shut off all outputs after 4 hours of inactivity as a battery saving fea...

Страница 8: ...up Button A ESTOP FAULT LINK STATUS Setup Button B 5 Put R160 into Setup Mode 6 Download ID Code ESTOP FAULT LINK STATUS A Press Power switch UP and release B Link light goes to GREEN Once complete Li...

Страница 9: ...0 B ESTOP FAULT LINK STATUS 1 Power T300 Power R160 A Hold Power switch DOWN for 5 seconds until the Battery LED goes to alter nating RED and YELLOW B Release Power switch 2 Setup T300 into Configurat...

Страница 10: ...e unit will power down The transmitter is in Calibration mode STOP STOP STOP STOP STOP STOP STOP STOP STOP STOP Light Legend Solid Slow Flash Fast Flash Red Light Green Light Alternating Red Yellow Li...

Страница 11: ...t is most likely caused by a wiring fault Ensure transmitter is functioning properly check status of each output connection Press each function button and observe Fault Light If GREEN everything is OK...

Страница 12: ...e is a short is the wiring after the discon nection point Stays flashing RED call for service What is the state of the Fault light Fault Light is OFF Fault Light is Flashing RED Fault Light is RED Cal...

Страница 13: ...o to solid YELLOW YES Either the switch paddle is defective or the switch paddle connection to the circuit board is broken Call for service Complete the following steps in order 1 Check battery orient...

Страница 14: ...units function correctly If not proceed to Chart 1 NO YES The transmitter code may need to be re downloaded to the receiver NO Caution Note Before you proceed with the Download ID procedure located o...

Страница 15: ...ssible Solutions 1 Try the Downloading steps again 2 If this doesn t correct the problem send both the transmitter and receiver in for service Note you could try to determine whether the fault lies wi...

Страница 16: ...he FCC Rules Operation is subject to the following two condi tions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that...

Отзывы: