background image

2.2 Rules for use

Bode 100

 is exclusively intended for the application area specified in this document. The

manufacturer/distributors are not liable for damage resulting from a use other than the specified
operation. The user alone assumes all responsibility and risk.

Use 

Bode 100

 only when it is in a technically sound condition.

Do not open 

Bode 100

 or remove any of its housing components.

Do not carry out any modifications, extensions or adaptations to 

Bode 100

.

Use 

Bode 100

 in observance of all existing safety requirements from national and international

standards for accident prevention and environmental protection.

Always keep the manual either printed or as PDF file at the site where 

Bode 100

 is used. The

manual must be read by all people working with 

Bode 100

. In addition to the manual and the

applicable regulations for accident prevention in the country and at the site of operation, heed the
accepted technical procedures for safe and competent work.

2.3 Designated use

Bode 100

 and its accessories are especially designed for swept frequency measurements of

electronic circuits in laboratory and manufacturing environments.
Examples for typical applications are:

Measurement of the complex transfer function of amplifiers, filters and attenuators

S-Parameter measurement in the 50 Ohm domain

Stability assessment of control loops

Determination of resonance frequencies of piezo elements and quartz crystals

Impedance measurement of inductors, capacitors and resistors

2.4 Disclaimer

The advisory procedures and information contained within this document have been compiled as a
guide to the safe and effective operation of 

Bode 100

. It has been prepared in conjunction with

application engineers and the collective experience of the manufacturer.

The in-service conditions for the use of 

Bode 100

 may vary between customers and end-users.

Consequently, this document is offered as a guide only. It shall be used in conjunction with the
customers own safety procedures, maintenance program, engineering judgment, and training
qualifications.

Using 

Bode 100

 or its accessories in a manner not specified by the manufacturer may result in

damage to property or persons.

2.5 Cleaning

Use a cloth dampened with isopropanol alcohol to clean 

Bode 100

 and its accessories.

Bode 100 Quick Start Guide

6

OMICRON Lab

Содержание Bode 100

Страница 1: ...Bode 100 Quick Start Guide...

Страница 2: ...c data processing systems requires the explicit consent of OMICRON electronics Reprinting wholly or in part is not permitted The product information specifications and technical data embodied in this...

Страница 3: ...e statement 7 3 2 Information for disposal and recycling 7 4 Bode 100 and accessories 8 4 1 Delivered items 8 4 2 Optional accessories 9 5 Device overview 11 6 Getting started 12 6 1 System requiremen...

Страница 4: ...tion available for Bode 100 Therefore we recommend to read the Bode 100 User Manual which is available in PDF format on the DVD delivered with Bode 100 Furthermore the Bode 100 User Manual can be view...

Страница 5: ...elevant for working with Bode 100 for example the regulation EN50191 Erection and Operation of Electrical Test Equipment WARNING Bode 100 is a SELV device SELV Safety Extra Low Voltage according to IE...

Страница 6: ...y measurements of electronic circuits in laboratory and manufacturing environments Examples for typical applications are Measurement of the complex transfer function of amplifiers filters and attenuat...

Страница 7: ...own expense Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment Declaration of compliance Canada This Class...

Страница 8: ...ndards Test objects Quartz filter and IF filter on PCB USB Cable 4 pc BNC 50 cables with 500 mm length m m BNC adapters straight T Short Load 50 Bode 100 Quick Start Guide Multilingual safety instruct...

Страница 9: ...B SMC Impedance Adapter for surface mount components The B SMC extends the impedance measurement range of Bode 100 It enables you to easily measure components for surface mounting such as ceramic capa...

Страница 10: ...of the resonance frequency and Q factor of RFID antennas Order numbers OL000170 OL000173 For more information on the above mentioned Bode 100 accessories and recommended accessories manufactured by p...

Страница 11: ...ck Further on a green LED is lit at the front panel when the Bode 100 is powered Figure 5 1 Bode 100 front view Bode 100 provides the following connectors at the back panel DC power input Type 5 5 mm...

Страница 12: ...uto run function of your computer s operating system navigate to the root directory of the DVD and start the setup manually If you have no DVD drive on your computer you can download the latest versio...

Страница 13: ...problems with the USB connection try to connect your Bode 100 directly to a USB port of your computer The same applies to some USB isolators 6 5 Performing your first measurement Follow the steps des...

Страница 14: ...isplayed like shown in the figure above see 1 If no serial number is displayed refer to the section Troubleshooting for further information To start your first measurement click the file name TransRef...

Страница 15: ...hile the blue curve shows the reflection S11 of the IF filter Please refer to the Bode 100 User Manual for more information on the Bode 100 and its measurement capabilities You can view the user manua...

Страница 16: ...ayed in the start screen see 6 2 on page 14 or in the right bottom corner of the measurement screen see 6 3 on page 15 a Check if the USB cable is properly plugged into the computer and the Bode 100 b...

Страница 17: ...ine you can reach well educated technicians for all of your questions Competent and free of charge Make use of our technical support hotlines Americas 1 713 830 4660 or 1 800 OMICRON Asia Pacific 852...

Страница 18: ...Items 8 Device Overview 11 Disposal 7 E Email OMICRON Lab email address 17 G Getting Started 12 H Hotline 17 O Operating System 12 P PC Requirements 12 R Recycling 7 S SAFETY Designated use 6 Disclaim...

Страница 19: ...T Technical support 17 Troubleshooting Check power 16 Check USB connection 16 Search and reconnect 16 Troubleshooting 16 U User Manual 13 W Web OMICRON Lab website 17 Index OMICRON Lab 19...

Страница 20: ...info omicron lab com www omicron lab com Bode 100 Quick Start Guide English OMICRON Lab 2019 Version 2 0 ENU 1006 03 02...

Отзывы: