B-AMP 12 User Manual 

 

 

Technical data 

Table 5-1 

Specifications 

General characteristic 

Rating 

Frequency range 

DC 

– 50 MHz 

Gain (1 Hz 

– 50 MHz) 

12 dB ±0.2

5 dB into 50 Ω 

Signal connector type 

BNC 

Input Characteristic

 

Rating

 

Maximum input signal 

≤ 1 V

RMS

 (

 13 dBm / 2.83 V

PP

Input impedance 

50 Ω 

Input return loss 

> 30 dB 

Damage level 

10 V

PP

 

Output Characteristic 

Rating 

Maximum output amplitude 

25 dBm (

 

11.3 V

PP

into 50 Ω 

Output impedance 

50 Ω 

Output return loss 

> 30 dB 

Output DC offset 

< 10 mV (input and output terminated with 50 Ω) 

Damage reverse power 

1 W 

Input to CH1 attenuation 

14.5 dB 

typ. (output terminated with 50 Ω) 

Input to CH2 attenuation 

20.8 dB 

typ. (output terminated with 50 Ω) 

Output to CH2 voltage gain 

-33 dB (

 

x0.022) into 50 Ω 

Table 5-2 

DC power requirements 

Characteristic 

Rating 

Supply voltage range 

10 

– 36 V

DC

 

Power consumption 

at 12 V: < 440mA typ. 

at 24 V: < 220mA typ. 

Power connector / socket 

Coaxial power socket (2.5 mm / 5.5 mm) 

Inner connector positive polarity (+) 

 

 

 

Содержание B-AMP 12

Страница 1: ...B AMP 12 Power amplifier for Bode 100 User Manual Distributed by dataTec Ferdinand Lassalle Str 52 72770 Reutlingen Tel 07121 51 50 50 Fax 07121 51 50 10 info datatec de www datatec de...

Страница 2: ...tion and or storage in electronic data processing systems requires the explicit consent of OMICRON electronics Reprinting wholly or in part is not permitted The product information specifications and...

Страница 3: ...for household use After use the test set cannot be disposed of as household waste For customers in EU countries incl European Economic Area OMICRON test sets are subject to the EU Waste Electrical an...

Страница 4: ...aller or equal to 1 Vrms in the frequency range from DC 50 MHz B AMP 12 has been especially designed for the use in laboratory and manufacturing environments Safety symbols used In this manual the fol...

Страница 5: ...is a SELV device Safety Extra Low Voltage in accordance to IEC 60950 also known as protection class III equipment Do not apply hazardous voltage levels 50 VDC or 25 VAC to any input or output of B AMP...

Страница 6: ...1 output connector BNC plug to measure the internal voltage attenuated Power supply connector Supply the B AMP 12 with 10 V DC to 36 V DC Channel 2 output connector BNC plug to measure the output vol...

Страница 7: ...cal setup where B AMP 12 is used to amplify the output signal of the Bode 100 vector network analyzer to measure S21 of a 2 port DUT using up to 25 dBm signal level Figure 4 2 shows a typical setup us...

Страница 8: ...tput amplitude 25 dBm 11 3 VPP into 50 Output impedance 50 Output return loss 30 dB Output DC offset 10 mV input and output terminated with 50 Damage reverse power 1 W Input to CH1 attenuation 14 5 dB...

Страница 9: ...rature 5 C 40 C 41 F 104 F Storage temperature 35 C 60 C 31 F 140 F Relative humidity 20 80 non condensing Table 5 4 Mechanical data Characteristic Rating Dimensions with connectors 138 mm x 75 mm x 3...

Страница 10: ...b com At our technical support hotline you can reach well educated technicians for all your questions Competent and free of charge Make use of our technical support hotlines Americas 1 713 830 4660 or...

Страница 11: ...www omicron lab com OMICRON Lab 2017 B AMP 12 User Manual English All rights reserved ENU11880501 Distributed by dataTec Ferdinand Lassalle Str 52 72770 Reutlingen Tel 07121 51 50 50 Fax 07121 51 50 1...

Отзывы: