Mounting the fixture in areas away from reach by unauthorized
personal is always recommended. Before mounting the fixture
make sure that the area you are using can hold a minimum
load of 5x the Fixtures weight. You must always use a
secondary safety attachment, such as a safety cable.
The
TitanBeam™ 7R is fully operational in two install positions,
hanging upside down on a truss or by setting it on a flat level
surface. Always make sure that all fixture are kept at least
0.5m away from any flammable materials.
For best results TitanBeam™ 7R requires routine cleaning and
maintenance. Excessive dust, smoke fluid, and particulate buildup
will degrade the performance and will cause the fixture to overheat.
The damage from this is not is not covered in the manufacture
warranty. Always make sure you unplug the fixture before opening
any covers for cleaning. Optical components should be cleaned
carefully and do not use any harmful solvents to avoid damage.
Remember to keep all air vents clean and free from clutter that will
prevents constant air flow.
7. Installation
8. Cleaning & Maintanance
Standard
mode
16Bit
mode
Channel
function
Value
Function
8
8
Frost
0-127
No Frost
128-255
Frost
9
9
Focus
0
Focus 0%
…
….
255
Focus 100%
10
10
Pan
0-255
0-540°
11
11
Pan Fine
0-255
Adjustment
12
12
Tilt
0-255
0-270°
13
13
Tilt fine
0-255
Adjustment
14
14
Motor Speed
0-255
Pan/Tilt Speed
15
15
Reset
0-25
Unused Range
26-76
Effect Reset
77-127
Pan/Tilt Reset
128-255
Complete Reset
16
16
Lamp control
0-9
Lamp On
10-100
Lamp Off
101-255
Unused
-
17
Pan/tilt
Time
0-255
Fast-slow
-
18
Color time
0-255
Fast
-
19
Beam time
0-255
Fast
-
20
Gobo time
0-255
Fast
When resetting fixture please allow an average of 20 sec. for the fixture to reset all
sensors and motors. Fixture will continue where it left off. The lamp will stay on so
there is no cool off wait time. Always remember if the light bulb turns of at any time
during operation there is a 5-10 minute cool down period before bulb ignites.